User manual YAMAHA XP7000 XP5000 XP3500 XP2500 XP1000

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual YAMAHA XP7000 XP5000 XP3500 XP2500 XP1000. We hope that this YAMAHA XP7000 XP5000 XP3500 XP2500 XP1000 user guide will be useful to you.


YAMAHA XP7000 XP5000 XP3500 XP2500 XP1000 : Download the complete user guide (1048 Ko)

You may also download the following manuals related to this product:

   YAMAHA XP7000 XP5000 XP3500 XP2500 XP1000 (1043 ko)
   YAMAHA XP7000 XP5000 XP3500 XP2500 XP1000 (3139 ko)
   YAMAHA XP7000 XP5000 XP3500 XP2500 XP1000 (1044 ko)
   YAMAHA XP7000 XP5000 XP3500 XP2500 XP1000 (1037 ko)
   YAMAHA XP7000 XP5000 XP3500 XP2500 XP1000 ?? (1379 ko)
   YAMAHA XP7000 XP5000 XP3500 XP2500 XP1000 戵־ (1285 ko)
   YAMAHA XP7000 XP5000 XP3500 XP2500 XP1000 ANNEXE 2 (9386 ko)
   YAMAHA XP7000 XP5000 XP3500 XP2500 XP1000 ANNEXE 2 (9381 ko)
   YAMAHA XP7000 XP5000 XP3500 XP2500 XP1000 ANNEXE 2 (9376 ko)
   YAMAHA XP7000 XP5000 XP3500 XP2500 XP1000 ANNEXE 1 (4898 ko)
   YAMAHA XP7000 XP5000 XP3500 XP2500 XP1000 ANNEXE 1 (8145 ko)
   YAMAHA XP7000 XP5000 XP3500 XP2500 XP1000 ANNEXE 2 (9376 ko)
   YAMAHA XP7000 XP5000 XP3500 XP2500 XP1000 ANNEXE 3 (9386 ko)
   YAMAHA XP7000 XP5000 XP3500 XP2500 XP1000 annexe 1 (1161 ko)
   YAMAHA XP7000 XP5000 XP3500 XP2500 XP1000 ANNEXE 1 (8145 ko)

Manual abstract: user guide YAMAHA XP7000 XP5000 XP3500 XP2500 XP1000

Detailed instructions for use are in the User's Guide.

[. . . ] POWER AMPLIFIER EN DE FR ES Español OWNER'S MANUAL BEDIENUNGSANLEITUNG MODE D'EMPLOI MANUAL DE INSTRUCCIONES Français Deutsch English FCC INFORMATION (U. S. A. ) 1. IMPORTANT NOTICE: DO NOT MODIFY THIS UNIT! This product, when installed as indicated in the instructions contained in this manual, meets FCC requirements. Modifications not expressly approved by Yamaha may void your authority, granted by the FCC, to use the product. 2. IMPORTANT: When connecting this product to accessories and/or another product use only high quality shielded cables. [. . . ] · A high pass filter switch that enables selection of the cutoff frequency (20Hz or 55Hz). · Signal indicator, clip indicator and sophisticated dB step Volume control are provided for each channel. If the amplifier has been set to STANDBY mode, the indicator is lit in orange. Lights up green when the corresponding channel's output level exceeds 2 Vrms (equivalent to 1/2 W into an 8 load, or 1 W into a 4 load). 6 Volume control knobs Each control knob adjusts the volume of the corresponding channel, in 31 steps from - dB to 0 dB. * If you wish to lock in the knob settings, you can fasten the supplied security cover over the knobs so that the settings will not be disturbed. 2 TEMP indicator Lights up red if the heat sink temperature exceeds 85°C (185°F). 3 PROTECTION indicator When the protection system is active, the PROTECT indicator light up in red and the speakers are automatically disconnected from the amplifier's outputs. The protection system activates in the following situations: When the amplifier is turned on The protection system activates for approximately three seconds when the amplifier is turned on. After three seconds, the protection system deactivates automatically and the amplifier is ready for normal operation. If a DC voltage is detected at the amplifier's outputs How to install the security cover (1) Use the supplied hex wrench to remove the four attachment screws from the amplifier. Fasten it into place using the same screws. XP7000/5000: Power shut down and the indicator is not lit. Once the DC voltage problem is corrected, the protection system deactivates automatically and the amplifier is ready for normal operation. If the amplifier overheats 7 Air intakes The amplifier uses forced-air cooling. The cooling fans draw air in from the front and exhaust it through the rear. Please be sure that you do not block the air intakes or exhaust vents. * The fans do not come on at initial power-on, but will switch on automatically when the temperature of the heat sink rises above 50°C (122°F). The fan speed will then vary automatically as the temperature changes. Front Rear When overheating occurs, the PROTECT/MUTE indicator lights. You should immediately turn off the amplifier and allow it time to cool down. See the Precautions section of this Owner's Manual for ways to prevent the amplifier from overheating. 4 CLIP indicator Lights up red when the output signal distortion on the corresponding channel rises above 1% -- indicating that "clipping" has occurred bacause the signal level is too high. Air intake Air exhaust 6 XP7000/XP5000/XP3500/XP2500/XP1000 Owner's Manual Rear Panel 4 3 5 6 7 1 1 XLR inputs connectors 2 7 5 MODE switch 8 These balanced XLR-3-31 type connectors are used to connect input signals. The pins are wired as shown below (IEC 60268). Hot Ground Cold * In bridged mode, only the first channel in the pair is active; i. e. , channel A of pair A/B. Make sure not to input an audio signal to an inactive input terminal. · STEREO mode In STEREO mode, channels A and B are completely independent. · PARALLEL mode In PARALLEL mode, the channel A input signal is sent both to the channel A power amp and the channel B power amp. In this case, loads are automatically connected between the A and B input terminals. · BRIDGED mode In BRIDGED mode, channels A and B operate simultaneously, functioning as a single mono amplifier. Note: When in PARALLEL and BRIDGED modes, input terminals A and B are shorted automatically. Make sure not to input an audio signal to an inactive input terminal. 2 Euroblock connectors These balanced Euroblock connectors are used to connect input signals. 6 MONITOR/REMOTE terminals This terminal is used to connect the external device for monitoring or remote control. Refer to "MONITOR/ REMOTE PIN layout" on page 15. 3 HPF switches These switches are used to turn on and off the HPF (High Pass Filter) for each channel. When this is set to 20Hz or 55Hz, frequencies below the respective settings are filtered using a 12 dB/octave high pass filter. 7 SPEAKERS terminals 1: These 5-way binding posts are used to connect speakers. Speakon type cable plugs can be connected here. 4 GAIN switch This switch is used when changing the Gain of the A and B channels simultaneously. · +4dBu: The maximum output power can be obtained when +4dBu is input. [. . . ] reserves the right to change or modify products or specifications at any time without prior notice. Since specifications, equipment or options may not be the same in every locale, please check with your Yamaha dealer. 14 XP7000/XP5000/XP3500/XP2500/XP1000 Owner's Manual MONITOR/REMOTE PIN layout Pin No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Signal GND REMOTE CONTROL MONITOR REMOTE CONTROL MUTE CH B MUTE CH A MONITOR NC NC PROTECT STATUS CH B PROTECT STATUS CH A NC NC OUTPUT LEVEL CH B OUTPUT LEVEL CH A STANDBY MODEL ID NC NC MUTE Control: Connect to GND, +5 V, 1 mA Description STANDBY Control: Supply 5 VDC, 5 mADC XP7000: 1. 0 k, XP5000: 1. 2 k, XP3500: 1. 5 k, XP2500: 1. 8 k, XP1000: 2. 2 k (Impedance to GND) PROTECTION Off/ Output On: +5 VDC, Zo=270 PROTECTION On/ Output Off: 0 VDC, Zo=High XP7000, XP5000, XP3500, XP2500, XP1000 +4dBu (-27. 2 dB of Speaker Output Level) at 100 W/8, RL=7. 5 k, Zo=300 Dimensions Unit: mm 374. 5 30 46 30 362 480 30 5. 5 88 456 XP7000/XP5000/XP3500/XP2500/XP1000 Owner's Manual 15 16 CLIP/LIMIT CH A CH B RE LED DRIVE CIRCUIT ACL BCL ASIG BSIG RE GR GR RE RE CH A CH B TEMP PROTECTION SIGNAL OFF BA HPF 55Hz HPF 20Hz 20Hz XLR XP7000/XP5000 1 2 Block Diagram 3 HA 55Hz 1­ 2­ 2+ A MUTE A DC LED DRIVE CIRCUIT A MUTE APS LIMITER PA SPEAKON 1+ CH A-2 (A+B BRIDGE) CH A TM PR CH A ATT +4dBu +26dB +32dB TEMPERATURE SENSOR +60°C +90°C TEMP 1+ 1­ 2­ CH B-2 2+ SPEAKON B DC B MUTE OFF STEREO BRIDGE 20Hz G INPUT HPF 12dB/oct INV +60°C +90°C PROTECTION CIRCUIT B MUTE BPS [+22dBu MAX] ­ + G ­ + GAIN TEMPERATURE SENSOR Euroblock CH B SHUTDOWN STEREO OUTPUT (SPEAKERS) ­ + + ­ 5way CH A-1 (A+B BRIDGE) CH B-1 BRIDGE 1 2 PARALLEL BA LIMITER HPF 55Hz HPF 20Hz CH B ATT PA +4dBu +26dB +32dB 3 HA 55Hz PARALLEL XLR STEREO XP7000/XP5000/XP3500/XP2500/XP1000 Owner's Manual MODE BRIDGE PARALLEL FAN (L) FAN CONTROL CIRCUIT FAN (R) DATA PORT (MONITOR/REMOTE) POWER/STANDBY PO SBY LED DRIVE CIRCUIT POWER ON DETECT CIRCUIT +24 +5V MAIN TRANS +15V +5 GR/OR (GR+RE) +15V B OUTPUT LEVEL A OUTPUT LEVEL MUTE PROTECT STATUS STANDBY Model ID SUB TRANS POWER SW Thermal cutoff RELAY +15 LINE FILTER ­15V ­15 ­24 SWITCHING +B DRIVER ­B SHUTDOWN CIRCUIT OVERCURRENT DETECT CIRCUIT TEMPERATURE SENSOR LATCH CIRCUIT +100°C FG RELAY DRIVE CIRCUIT J, H destination +24 U, A destination CLIP/LIMIT CH A CH B CH A CH B TEMP PROTECTION SIGNAL RE RE GR GR RE RE LED DRIVE CIRCUIT ACL BCL ASIG BSIG XLR OFF SP RELAY LIMITER PA BA +4dBu +26dB +32dB A RY HPF 12dB/oct INV +90°C TEMPERATURE SENSOR A MUTE APS 1 2 3 HA HPF 55Hz HPF 20Hz 20Hz CH A TM PR LED DRIVE CIRCUIT CH A ATT 2+ 55Hz SPEAKON 1+ CH A-2 1­ 2­ (A+B BRIDGE) G INPUT A DC TEMP PROTECTION CIRCUIT B DC BPS XP3500/XP2500/XP1000 [+22dBu MAX] ­ + G ­ + GAIN +60°C B MUTE 1+ 1­ 2­ 2+ SPEAKON ­ CH B-2 Euroblock CH B OFF STEREO BRIDGE STEREO B RY + LIMITER PA OUTPUT (SPEAKERS) CH A-1 BRIDGE 1 2 PARALLEL BA 55Hz PARALLEL HPF 20Hz 20Hz CH B ATT +4dBu +26dB +32dB 3 HA SP RELAY 5way + CH B-1 ­ (A+B BRIDGE) XLR STEREO HPF 55Hz BRIDGE PARALLEL MODE FAN CONTROL CIRCUIT DATA PORT (MONITOR/REMOTE) RELAY & LED DRIVE CIRCUIT PO SBY B OUTPUT LEVEL A OUTPUT LEVEL MUTE PROTECT STATUS STANDBY Model ID POWER/STANDBY GR/OR (GR+RE) MAIN TRANS +15V +15 +24 POWER SW FAN RELAY 1 ­15V ­15 ­24 +B J destination only RELAY 2 Except J destination 130°C Thermal Thermal cutoff protector ­B FG XP7000/XP5000/XP3500/XP2500/XP1000 Owner's Manual SUB TRANS Thermal cutoff 17 Performance Graphs XP7000 Mode:STEREO Both ch Driven RL=4 , f=1 kHz XP2500 Mode:STEREO Both ch Driven RL=4 , f=1 kHz 10000 10000 Power Consumption [W] 1000 Power Consumption [W] 1 10 100 1000 10000 1000 100 100 10 10 1 1 1 10 100 1000 Output Power [W] Output Power [W] XP5000 Mode:STEREO Both ch Driven RL=4 , f=1 kHz XP1000 Mode:STEREO Both ch Driven RL=4 , f=1 kHz 10000 1000 Power Consumption [W] 1000 Power Consumption [W] 100 100 10 10 1 1 10 100 1000 1 1 10 100 1000 Output Power [W] Output Power [W] XP3500 Mode:STEREO Both ch Driven RL=4 , f=1 kHz 10000 Power Consumption [W] 1000 100 10 1 1 10 100 1000 Output Power [W] 18 XP7000/XP5000/XP3500/XP2500/XP1000 Owner's Manual For details of products, please contact your nearest Yamaha representative or the authorized distributor listed below. Pour plus de détails sur les produits, veuillez-vous adresser à Yamaha ou au distributeur le plus proche de vous figurant dans la liste suivante. Die Einzelheiten zu Produkten sind bei Ihrer unten aufgeführten Niederlassung und bei Yamaha Vertragshändlern in den jeweiligen Bestimmungsländern erhältlich. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE YAMAHA XP7000 XP5000 XP3500 XP2500 XP1000




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual YAMAHA XP7000 XP5000 XP3500 XP2500 XP1000 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.