Detailed instructions for use are in the User's Guide.
[. . . ] POWER AMPLIFIER
EN DE FR ES
Español
OWNER'S MANUAL BEDIENUNGSANLEITUNG MODE D'EMPLOI MANUAL DE INSTRUCCIONES
Français
Deutsch
English
FCC INFORMATION (U. S. A. )
1. IMPORTANT NOTICE: DO NOT MODIFY THIS UNIT!
This product, when installed as indicated in the instructions contained in this manual, meets FCC requirements. Modifications not expressly approved by Yamaha may void your authority, granted by the FCC, to use the product.
2. IMPORTANT: When connecting this product to accessories and/or another product use only high quality shielded cables. [. . . ] · A high pass filter switch that enables selection of the cutoff frequency (20Hz or 55Hz). · Signal indicator, clip indicator and sophisticated dB step Volume control are provided for each channel. If the amplifier has been set to STANDBY mode, the indicator is lit in orange.
Lights up green when the corresponding channel's output level exceeds 2 Vrms (equivalent to 1/2 W into an 8 load, or 1 W into a 4 load).
6 Volume control knobs
Each control knob adjusts the volume of the corresponding channel, in 31 steps from - dB to 0 dB.
* If you wish to lock in the knob settings, you can fasten the supplied security cover over the knobs so that the settings will not be disturbed.
2 TEMP indicator
Lights up red if the heat sink temperature exceeds 85°C (185°F).
3 PROTECTION indicator
When the protection system is active, the PROTECT indicator light up in red and the speakers are automatically disconnected from the amplifier's outputs. The protection system activates in the following situations:
When the amplifier is turned on
The protection system activates for approximately three seconds when the amplifier is turned on. After three seconds, the protection system deactivates automatically and the amplifier is ready for normal operation.
If a DC voltage is detected at the amplifier's outputs
How to install the security cover (1) Use the supplied hex wrench to remove the four attachment screws from the amplifier. Fasten it into place using the same screws.
XP7000/5000: Power shut down and the indicator is not lit. Once the DC voltage problem is corrected, the protection system deactivates automatically and the amplifier is ready for normal operation.
If the amplifier overheats
7 Air intakes
The amplifier uses forced-air cooling. The cooling fans draw air in from the front and exhaust it through the rear. Please be sure that you do not block the air intakes or exhaust vents.
* The fans do not come on at initial power-on, but will switch on automatically when the temperature of the heat sink rises above 50°C (122°F). The fan speed will then vary automatically as the temperature changes.
Front Rear
When overheating occurs, the PROTECT/MUTE indicator lights. You should immediately turn off the amplifier and allow it time to cool down. See the Precautions section of this Owner's Manual for ways to prevent the amplifier from overheating.
4 CLIP indicator
Lights up red when the output signal distortion on the corresponding channel rises above 1% -- indicating that "clipping" has occurred bacause the signal level is too high.
Air intake
Air exhaust
6
XP7000/XP5000/XP3500/XP2500/XP1000 Owner's Manual
Rear Panel 4 3 5 6 7
1 1 XLR inputs connectors
2
7 5 MODE switch
8
These balanced XLR-3-31 type connectors are used to connect input signals. The pins are wired as shown below (IEC 60268).
Hot
Ground
Cold
* In bridged mode, only the first channel in the pair is active; i. e. , channel A of pair A/B. Make sure not to input an audio signal to an inactive input terminal.
· STEREO mode In STEREO mode, channels A and B are completely independent. · PARALLEL mode In PARALLEL mode, the channel A input signal is sent both to the channel A power amp and the channel B power amp. In this case, loads are automatically connected between the A and B input terminals. · BRIDGED mode In BRIDGED mode, channels A and B operate simultaneously, functioning as a single mono amplifier.
Note: When in PARALLEL and BRIDGED modes, input terminals A and B are shorted automatically. Make sure not to input an audio signal to an inactive input terminal.
2 Euroblock connectors
These balanced Euroblock connectors are used to connect input signals.
6 MONITOR/REMOTE terminals
This terminal is used to connect the external device for monitoring or remote control. Refer to "MONITOR/ REMOTE PIN layout" on page 15.
3 HPF switches
These switches are used to turn on and off the HPF (High Pass Filter) for each channel. When this is set to 20Hz or 55Hz, frequencies below the respective settings are filtered using a 12 dB/octave high pass filter.
7 SPEAKERS terminals
1: These 5-way binding posts are used to connect speakers. Speakon type cable plugs can be connected here.
4 GAIN switch
This switch is used when changing the Gain of the A and B channels simultaneously. · +4dBu: The maximum output power can be obtained when +4dBu is input. [. . . ] reserves the right to change or modify products or specifications at any time without prior notice. Since specifications, equipment or options may not be the same in every locale, please check with your Yamaha dealer.
14
XP7000/XP5000/XP3500/XP2500/XP1000 Owner's Manual
MONITOR/REMOTE PIN layout
Pin No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Signal GND REMOTE CONTROL MONITOR REMOTE CONTROL MUTE CH B MUTE CH A MONITOR NC NC PROTECT STATUS CH B PROTECT STATUS CH A NC NC OUTPUT LEVEL CH B OUTPUT LEVEL CH A STANDBY MODEL ID NC NC MUTE Control: Connect to GND, +5 V, 1 mA Description STANDBY Control: Supply 5 VDC, 5 mADC XP7000: 1. 0 k, XP5000: 1. 2 k, XP3500: 1. 5 k, XP2500: 1. 8 k, XP1000: 2. 2 k (Impedance to GND)
PROTECTION Off/ Output On: +5 VDC, Zo=270 PROTECTION On/ Output Off: 0 VDC, Zo=High
XP7000, XP5000, XP3500, XP2500, XP1000 +4dBu (-27. 2 dB of Speaker Output Level) at 100 W/8, RL=7. 5 k, Zo=300
Dimensions
Unit: mm
374. 5
30
46
30
362 480
30
5. 5 88
456
XP7000/XP5000/XP3500/XP2500/XP1000 Owner's Manual
15
16
CLIP/LIMIT CH A CH B RE LED DRIVE CIRCUIT ACL BCL ASIG BSIG RE GR GR RE RE CH A CH B TEMP PROTECTION SIGNAL OFF BA
HPF 55Hz HPF 20Hz 20Hz
XLR
XP7000/XP5000
1
2
Block Diagram
3
HA 55Hz 1 2 2+ A MUTE A DC LED DRIVE CIRCUIT A MUTE
APS
LIMITER PA
SPEAKON 1+ CH A-2 (A+B BRIDGE)
CH A TM PR
CH A ATT
+4dBu +26dB +32dB TEMPERATURE SENSOR +60°C +90°C TEMP 1+ 1 2 CH B-2 2+ SPEAKON B DC B MUTE OFF STEREO
BRIDGE 20Hz
G
INPUT
HPF 12dB/oct INV +60°C +90°C PROTECTION CIRCUIT B MUTE
BPS
[+22dBu MAX]
+
G
+
GAIN
TEMPERATURE SENSOR
Euroblock
CH B SHUTDOWN
STEREO
OUTPUT (SPEAKERS)
+ + 5way CH A-1 (A+B BRIDGE) CH B-1
BRIDGE
1
2
PARALLEL BA LIMITER
HPF 55Hz HPF 20Hz
CH B ATT PA
+4dBu +26dB +32dB
3
HA 55Hz PARALLEL
XLR
STEREO
XP7000/XP5000/XP3500/XP2500/XP1000 Owner's Manual
MODE
BRIDGE
PARALLEL
FAN (L)
FAN CONTROL CIRCUIT
FAN (R)
DATA PORT (MONITOR/REMOTE)
POWER/STANDBY
PO SBY LED DRIVE CIRCUIT POWER ON DETECT CIRCUIT +24 +5V MAIN TRANS +15V +5
GR/OR (GR+RE) +15V
B OUTPUT LEVEL A OUTPUT LEVEL MUTE PROTECT STATUS STANDBY Model ID
SUB TRANS
POWER SW
Thermal cutoff
RELAY
+15
LINE FILTER 15V 15 24 SWITCHING +B DRIVER B SHUTDOWN CIRCUIT OVERCURRENT DETECT CIRCUIT TEMPERATURE SENSOR LATCH CIRCUIT +100°C
FG
RELAY DRIVE CIRCUIT
J, H destination
+24
U, A destination
CLIP/LIMIT CH A CH B CH A CH B TEMP PROTECTION
SIGNAL
RE RE GR GR RE RE LED DRIVE CIRCUIT ACL BCL ASIG BSIG
XLR OFF SP RELAY LIMITER PA BA +4dBu +26dB +32dB A RY HPF 12dB/oct INV +90°C TEMPERATURE SENSOR A MUTE
APS
1
2
3
HA
HPF 55Hz
HPF 20Hz 20Hz
CH A TM PR LED DRIVE CIRCUIT
CH A ATT 2+
55Hz
SPEAKON 1+ CH A-2 1 2 (A+B BRIDGE)
G
INPUT
A DC TEMP PROTECTION CIRCUIT B DC
BPS
XP3500/XP2500/XP1000
[+22dBu MAX]
+
G
+
GAIN
+60°C B MUTE
1+ 1 2 2+ SPEAKON CH B-2
Euroblock
CH B OFF STEREO
BRIDGE
STEREO
B RY + LIMITER PA
OUTPUT (SPEAKERS)
CH A-1
BRIDGE
1
2
PARALLEL BA 55Hz PARALLEL
HPF 20Hz 20Hz
CH B ATT
+4dBu +26dB +32dB
3
HA
SP RELAY
5way
+ CH B-1 (A+B BRIDGE)
XLR
STEREO
HPF 55Hz
BRIDGE
PARALLEL MODE FAN CONTROL CIRCUIT
DATA PORT (MONITOR/REMOTE)
RELAY & LED DRIVE CIRCUIT PO SBY
B OUTPUT LEVEL A OUTPUT LEVEL MUTE PROTECT STATUS STANDBY Model ID
POWER/STANDBY
GR/OR (GR+RE) MAIN TRANS +15V +15 +24
POWER SW
FAN
RELAY 1 15V 15 24 +B
J destination only
RELAY 2
Except J destination
130°C Thermal Thermal cutoff protector
B
FG
XP7000/XP5000/XP3500/XP2500/XP1000 Owner's Manual
SUB TRANS
Thermal cutoff
17
Performance Graphs XP7000
Mode:STEREO Both ch Driven RL=4 , f=1 kHz
XP2500
Mode:STEREO Both ch Driven RL=4 , f=1 kHz
10000
10000
Power Consumption [W]
1000
Power Consumption [W]
1 10 100 1000 10000
1000
100
100
10
10
1
1
1
10
100
1000
Output Power [W]
Output Power [W]
XP5000
Mode:STEREO Both ch Driven RL=4 , f=1 kHz
XP1000
Mode:STEREO Both ch Driven RL=4 , f=1 kHz
10000
1000
Power Consumption [W]
1000
Power Consumption [W]
100
100
10
10
1
1
10
100
1000
1
1
10
100
1000
Output Power [W]
Output Power [W]
XP3500
Mode:STEREO Both ch Driven RL=4 , f=1 kHz
10000
Power Consumption [W]
1000
100
10
1
1
10
100
1000
Output Power [W]
18
XP7000/XP5000/XP3500/XP2500/XP1000 Owner's Manual
For details of products, please contact your nearest Yamaha representative or the authorized distributor listed below. Pour plus de détails sur les produits, veuillez-vous adresser à Yamaha ou au distributeur le plus proche de vous figurant dans la liste suivante.
Die Einzelheiten zu Produkten sind bei Ihrer unten aufgeführten Niederlassung und bei Yamaha Vertragshändlern in den jeweiligen Bestimmungsländern erhältlich. [. . . ]