User manual YAESU VX-451
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual YAESU VX-451. We hope that this YAESU VX-451 user guide will be useful to you.
Manual abstract: user guide YAESU VX-451
Detailed instructions for use are in the User's Guide.
[. . . ] VX-450 SERIES
OPERATING MANUAL
PROGRAMMABLE FUNCTIONS/FEATURES
IP57 Submersible (1 m/30 min. ) Programmable Function Keys 2-tone Encode/Decode 5-tone Encode/Decode MDC-1200® Encode/Decode Scan Group Scan Dual Watch FM-Scan (Follow-Me Scan) TA Scan Encryption Clear Voice VOX REC & PLAY (Requires DVS-8 or DVS-9) AF Min Volume Talk Around Man Down (Requires DVS-9) Emergency Lone Worker Direct Channel Entry1 Code Up/Down1 Code Set1 Speed Dial1 DTMF Code Set2 ID Check1 TX Save Disable ARTS (Auto Range Transpond System)
1: VX-454 & VX-459 ONLY 2: VX-459 ONLY
VX-451
VX-454
VX-459
CONTENTS
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Before You Begin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Low Battery Indication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Battery Charging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Instead, the radio will generate short beep three times and indicate " CH BUSY" on the display (VX-454 and VX459). Release the PTT switch and wait for the channel to be clear of activity. If CTCSS or Digital Coded Squelch (DCS) Lockout has been programmed on a channel, the radio can transmit only when there is no carrier being received or when the carrier being received includes the correct CTCSS tone or DCS code.
Automatic Time-Out Timer
If the selected channel has been programmed for automatic time-out, you must limit the length of each transmission. Another beep will sound just before the deadline; the "TX" indicator will disappear and transmission will cease soon thereafter. To resume transmitting, you must release the PTT switch and wait for the "penalty timer" to expire.
14
VX-450 SERIES OPERATING MANUAL
NOTE
VX-450 SERIES OPERATING MANUAL
15
ADVANCED OPERATION
Programmable Key Functions
All versions of the VX-450 include the TOP SEL, SIDE-1, and SIDE-2 key. The VX-454 and VX-459 include the [A], [B], [C], and [D] function keys. The Programmable key functions can be customized, via programming by your Vertex Standard dealer, to meet your communications/network requirements.
FUNCTION None Monitor Monitor -MomentarilyLamp 1 Low Power Encryption Set 1 SQL OFF SQL OFF -MomentarilySQL Set 1 Beep Off Whisper VOX VOX Set 1 Clear Voice AF Min Volume Emergency Lone Worker Group Up Group Down 1 Channel Up 1 Channel Down 1 Speed Channel Up 1 Speed Channel Down 1 TOP SEL / / / / / / / / / / / / / / / / / / / / / / / / SIDE-1 / / / / / / / / / / / / / / / / / / / / / / / /
Some features may require the purchase and installation of optional internal accessories. The possible Programmable key programming features are illustrated at the right, and their functions are explained on page 18. For future reference, check the box next to each function that has been assigned to the Programmable key on your particular radio, and keep it handy.
[ ]2 / / / / / / / / / / / / / / / / / / / / / / / / [#] 2 / / / / / / / / / / / / / / / / / / / / / / / /
PROGRAMMABLE KEY (PRESS KEY / PRESS AND HOLD KEY) [ A] 1 [B] 1 [C] 1 [D] 1 SIDE-2 / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / /
16
VX-450 SERIES OPERATING MANUAL
ADVANCED OPERATION
PROGRAMMABLE KEY (PRESS KEY / PRESS AND HOLD KEY) [A] 1 [B] 1 [C] 1 [D] 1 TOP SEL SIDE-1 SIDE-2 PRI-1 / / / / / / / PRI-2 / / / / / / / PRI-2 Set / / / / / / / PRI-2 Disable / / / / / / / Direct Channel #1 1 / / / / / / / 1 Direct Channel #2 / / / / / / / Direct Channel #3 1 / / / / / / / Direct Channel #4 1 / / / / / / / 1 Direct Channel Entry / / / / / / / Scan / / / / / / / Group Scan / / / / / / / Dual Watch / / / / / / / FM Scan / / / / / / / Scan Set / / / / / / / Group Scan Set / / / / / / / TA Scan / / / / / / / Talk Around / / / / / / / Reset / / / / / / / Call 1 / / / / / / / Call 2 / / / / / / / Call 3 / / / / / / / Call 4 / / / / / / / Call 5 / / / / / / / Code Up 1 / / / / / / / Code Down 1 / / / / / / / 1 Code Set / / / / / / / Speed Dial 1 / / / / / / / DTMF Code Set 2 / / / / / / / Call / / / / / / / Status Set 1 / / / / / / / Status Up 1 / / / / / / / 1 Status Down / / / / / / / Status Check 1 / / / / / / / Duty / / / / / / / Option SW 1 / / / / / / / Option SW 2 / / / / / / / 3 REC / / / / / / / PLAY 3 / / / / / / / TX Save Disable / / / / / / / Lock / / / / / / / 1: VX-454 and VX-459 only. FUNCTION [ ]2 / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / [#] 2 / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / /
VX-450 SERIES OPERATING MANUAL
17
ADVANCED OPERATION
Description of Operating Functions MONITOR
Press (or press and hold) the assigned Programmable key to cancel any signaling features; the BUSY/TX indicator will glow green.
ENCRYPTION
Press (or press and hold) the assigned Programmable key to toggle the Encryption feature "On" and "Off. "
SET
Press (or press and hold) the assigned Programmable key to activate the "User Set" (Menu) Mode. See page 30 for details
MONITOR -MOMENTARILYCancel any signaling features while pressing the assigned programmable key.
SQL OFF
Press (or press and hold) the assigned programmable key to open the SQL to hear background noise (unmute the audio).
LAMP
Press (or press and hold) the assigned Programmable key to illuminate the display for five seconds.
LOW POWER
Press (or press and hold) the assigned Programmable key to set the radio's transmitter to the "Low Power" mode, thus extending battery life. Press (or press and hold) the key again to return to "Normal" transmit power when in difficult terrain. When the radio's transmitter is set to "Low Power" mode, the "L" icon will be indicated on the display.
SQL OFF -MOMENTARILYOpens the SQL to hear background noise (unmute the audio) while pressing the assigned programmable key.
18
VX-450 SERIES OPERATING MANUAL
ADVANCED OPERATION
SQL SET
You can manually adjust the squelch level using this function: Press (or press and hold) the assigned Programmable key. A tone will sound, and the current squelch level will appear on the display. Press the SIDE-1/SIDE-2 button or [A]/[B] button to select the desired squelch level. The display indicates "- SET -" briefly, then reverts to the normal channel indication. In this case, the display indicates "- CANCEL -" briefly.
WHISPER
Press (or press and hold) the assigned Programmable key to increase the microphone gain; thus you can speak in a low voice (whisper) temporarily. Again press (or press and hold) the assigned Programmable key to resume normal microphone gain.
VOX
Press (or press and hold) the assigned programmable key to turn the VOX function "On" or "Off". You may disable the VOX function temporarily by pressing the PTT switch.
BEEP OFF
Press (or press and hold) the assigned Programmable key to disable the radio beeps temporarily. Again press (or press and hold) the assigned Programmable key to enable the radio beeps.
VX-450 SERIES OPERATING MANUAL
19
ADVANCED OPERATION
VOX SET
You can manually adjust the VOX Gain using this function:
Press (or press and hold) the assigned programmable key. A tone will sound, and the current VOX Gain level will appear on the display. The display indicates "- SET -" briefly, then reverts to the normal channel indication. [. . . ] The radio will sound the paging alert when it receives the programmed 2tone/5-tone code. When the Duty function is set to"Off, " the user will NOT hear normal radio traffic on the paging channel. The radio will sound the paging alert and unmute only when it receives the programmed 2-tone/5-tone code.
STATUS UP/DOWN
Press (or press and hold) the assigned Programmable key to select a 5-Tone status code from the pre-defined status list.
STATUS CHECK
Press (or press and hold) the assigned Programmable key to check the 5-Tone receive status code. When you press (or press and hold) this key, the display will indicate the "Message" corresponding to the receive status condition per the pre-defined status list.
OPTION SW1
Activates the optional accessory "1" while pressing the assigned Programmable key.
OPTION SW2
Press (or press and hold) the assigned Programmable key to toggle the optional accessory "2" "On" and "Off. "
VX-450 SERIES OPERATING MANUAL
27
ADVANCED OPERATION
REC (REQUIRES THE DVS-8 OR DVS-9)
Press (or press and hold) the assigned Programmable key to enable the Voice Recording Mode. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE YAESU VX-451
Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual YAESU VX-451 will begin.