User manual YAESU VX-170

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual YAESU VX-170. We hope that this YAESU VX-170 user guide will be useful to you.


YAESU VX-170 : Download the complete user guide (3160 Ko)

You may also download the following manuals related to this product:

   YAESU VX 170 (2464 ko)
   YAESU VX-170 (2616 ko)
   YAESU VX-170 BROCHURE (367 ko)
   YAESU VX-170 APRS MANUAL (3151 ko)
   YAESU VX-170 SERVICE MANUAL (2201 ko)

Manual abstract: user guide YAESU VX-170

Detailed instructions for use are in the User's Guide.

[. . . ] VHF FM TRANSCEIVER VX-170 OPERATING MANUAL VERTEX STANDARD CO. , LTD. 4-8-8 Nakameguro, Meguro-Ku, Tokyo 153-8644, Japan VERTEX STANDARD US Headquarters 10900 Walker Street, Cypress, CA 90630, U. S. A. YAESU EUROPE B. V. P. O. Box 75525, 1118 ZN Schiphol, The Netherlands YAESU UK LTD. Unit 12, Sun Valley Business Park, Winnall Close Winchester, Hampshire, SO23 0LB, U. K. VERTEX STANDARD HK LTD. Unit 5, 20/F. , Seaview Centre, 139-141 Hoi Bun Road, Kwun Tong, Kowloon, Hong Kong Contents General Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 LCD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Storing Independent Transmit Frequencies ("Odd Split") . . . . . . . . [. . . ] Recall the memory channel you wish to use as the "Priority" frequency. Now, set the radio for operation on a WX channel by pressing and holding in the [1(SQ TYP)] key for one second. Press the [F] key, then press the [VFO(PRI)] key to activate the WX Priority mode. The display will remain on the WX channel frequency, but every five seconds the radio will check the Priority Channel (memory channel) for activity. Press [F] [VFO(PRI)] again to disable the WX Priority mode. VFO-VFO Dual Watch 1. Press the [F] key, then press and hold in the [VFO(PRI)] key for one second. The VX-170 will now periodically change from VFO-A frequency to the VFO-B frequency, checking for activity on each VFO for 0. 2 second interval. Press the [VFO(PRI)] key to disable the VFO-VFO Dual Watch. Priority Revert Mode During Priority channel operation (Dual Watch), a special feature is available which will allow you to move to the Priority channel instantly, without waiting for activity to appear on the Priority channel. When this feature is enabled, and Priority monitoring is engaged, just press the PTT switch; operation will instantly revert to the Priority channel. Press the [F] key momentarily to enable adjustment of this Set Mode Item. Rotate the DIAL knob to set this Set Mode Item to "RVT. ON. " 5. When you have made your selection, press the PTT switch to save the setting and exit to normal operation. To disable the Priority Revert operation, just repeat the above procedure, rotating the DIAL knob to select "RVT. OFF" in step 4 above. VX-170 OPERATING MANUAL 43 SCANNING AUTOMATIC LAMP ILLUMINATION ON SCAN STOP The VX-170 will automatically illuminate the LCD/Keypad Lamp whenever the scanner stops on a signal; this allows you to see the frequency of the incoming signal better at night. Note that this will, of course, increase the battery consumption, so be sure to switch it off during the day (the default condition for this feature is "ON"). Press the [F] key momentarily to enable adjustment of this Set Mode Item. When you have made your selection, press the PTT switch to save the setting and exit to normal operation. BAND EDGE BEEPER The VX-170 will automatically "beep" when a band edge is encountered during scanning (either in standard VFO scanning or during PMS operation). You may also enable this feature (band edge beeper) to operate when the frequency reaches the band edge while tuning using the DIAL knob. Press the [F] key momentarily to enable adjustment of this Set Mode Item. When you have made your selection, press the PTT switch to save the setting and exit to normal operation. 44 VX-170 OPERATING MANUAL SCANNING WEATHER ALERT SCAN This feature allows you to check the Weather Broadcast Memory Channels for the presence of the NOAA Alert Tone while operating using VFO scan or Memory channel scan. When the Weather Alert Scan feature is engaged, the VX-170 will check the Weather Broadcast Memory Channels for activity every five seconds while scanning. If you watch the display carefully, you'll observe the scanner periodically shifting to the Weather Broadcast bank, scanning the Weather channels quickly in search of the Alert Tone, after which regular scanning will resume for another five seconds. Press the [F] key momentarily to enable adjustment of this Set Mode Item. [. . . ] Select the desired operating mode from the selections shown above. 78 VX-170 OPERATING MANUAL SET (MENU) MODE Set Mode Item 44 [SQL. TYP] Function: Selects the Tone Encoder and/or Decoder mode. Available Values: OFF/TONE/TSQL/REV TN/DCS/ECS Default: OFF TONE: CTCSS Encoder TSQL: CTCSS Encoder/Decoder REV TN: Reverse CTCSS Decoder (Mutes receiver when matching tone is received) DCS: Digital Coded Encoder/Decoder ECS: Enhanced Paging & & Code Squelch Note: See also Set Mode Item 43: SPLIT regarding additional selections available during "Split Tone" operation. Available Values: 5/10/12. 5/15/20/25/50/100 kHz, or AUTO Default: AUTO (Step automatically changes according to operating frequency. ) Set Mode Item 46 [TN FRQ] Function: Setting of the CTCSS Tone Frequency. Available Values: 50 standard CTCSS tones Default: 100. 0 Hz 67. 0 82. 5 100. 0 123. 0 151. 4 171. 3 189. 9 210. 7 250. 3 CTCSS TONE FREQUENCY (Hz) 69. 3 71. 9 74. 4 77. 0 79. 7 85. 4 88. 5 91. 5 94. 8 97. 4 103. 5 107. 2 110. 9 114. 8 118. 8 127. 3 131. 8 136. 5 141. 3 146. 2 156. 7 159. 8 162. 2 165. 5 167. 9 173. 8 177. 3 179. 9 183. 5 186. 2 192. 8 196. 6 199. 5 203. 5 206. 5 218. 1 225. 7 229. 1 233. 6 241. 8 254. 1 ­ ­ ­ ­ Set Mode Item 47 [TOT] Function: Setting of the TOT time Available Values: 1MIN - 30MIN or OFF Default: 6MIN (minutes) The time-out timer shuts off the transmitter after continuous transmission of the programmed time. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE YAESU VX-170




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual YAESU VX-170 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.