User manual YAESU FTDX9000 DATA MANAGEMENT OPERATION MANUAL

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual YAESU FTDX9000. We hope that this YAESU FTDX9000 user guide will be useful to you.


YAESU FTDX9000 DATA MANAGEMENT OPERATION MANUAL: Download the complete user guide (1522 Ko)

You may also download the following manuals related to this product:

   YAESU FTDX9000 UPDATE V0518 AND V11.53 (186 ko)
   YAESU FTDX9000 UPDATE V0518 AND V11.54 (187 ko)
   YAESU FTDX9000 UPDATE V0519 AND V11.54 INFORMATION (168 ko)

Manual abstract: user guide YAESU FTDX9000DATA MANAGEMENT OPERATION MANUAL

Detailed instructions for use are in the User's Guide.

[. . . ] FTDX9000MP/Contest Data Management OPERATION MANUAL FT DX 9000MP/CONTEST DATA MANAGEMENT OPERATION MANUAL PLEASE READ THIS FIRST When turning on the transceiver for the first time, please set the local time as soon as possible. If this is not done, the various functions of the World Clock and Great Circle Map will not function correctly. Note: If you wish to add a city to the City List that was programmed at the factory, you will need to supply your own USB or PS/2 Keyboard. If you utilize one of the pre-loaded cities, a keyboard is not necessary. [. . . ] If the screen returns to the previous screen (with the Marker displayed), the marker will remain on the screen. Page 16 FT DX 9000MP/CONTEST DATA MANAGEMENT OPERATION MANUAL SPECTRUM SCOPE USING THE CTR (CENTER) DISPLAY MODE Miscellaneous Functions SEARCHING FOR STRONG SIGNALS USING THE PEAK SEARCH FEATURE 1. Press the [1/1. 8](FUNC) key to show the screen for setup of the Marker. Press the [4/7](P. SRCH) key to move the marker to the highest peak signal frequency. With each press the [4/7](P. SRCH) key, the Marker will shift to the strongest signal frequency away from the current frequency. "PEAK SEARCH" mode CHANGING THE TRACE MODE 1. Press the [1/1. 8](FUNC) key to show the screen for setup of the Marker. Press the [6/14](TRACE) key to select the Trace mode of the Spectrum Scope. PEAK HOLD P: The signal level will be displayed, with peak strengths held for a few seconds. "TRACE" mode QMB MARKER If the QMB frequency is within the Spectrum Scope sweep range, the QMB channel's frequency will be displayed on the screen by a white arrow ( ). You may remove the QMB Marker from the screen via menu item "DISPLAY 020 QMB MARKER", if desired. QMB Marker FT DX 9000MP/CONTEST DATA MANAGEMENT OPERATION MANUAL Page 17 SPECTRUM SCOPE USING THE LBWS (LIMITED BAND WIDTH SWEEP) FUNCTION LBWS (Limited Band Width Sweep) is a function that sweeps a limited segment of the Spectrum Scope span without changing the span (bandwidth). As the sweep segment becomes narrower, the speed becomes faster, and the accuracy and resolution become enhanced. The sweep speed will increase as follows: 50 %: about 2 times faster, 30 %: about 3 times faster, 10 %: about 10 times faster 1. By pressing the [7/18](CTR/FIX) key repeatedly, the CTR mode and the FIX mode will be toggled alternately. By pressing the [2/3. 5](SPAN) key, you can set the bandwidth of the span viewed using the Spectrum Scope. By pressing the [3/5](ATT) key, the attenuation will change as follows. By pressing the [6/14](LBWS) key, the LBWS segment width will change as follows. Press the [4/7](A/B) key to select the Main (VFOA) or Sub (VFO-B) VFO. Advice:Please note that the LBWS feature can not be used in the FIX mode. While LBWS is engaged, it is not possible to switch to the dual display mode. In the case of the Contest version, the [RX] switch to the left of the [CLAR/VFO-B] knob will, when pushed, cause both the VFO itself and the Spectrum Scope display to change to VFO-B. Additionally, when the optional RXU-9000 Dual Receive Unit is installed, you may use the [4/7](A/B) key to make this change, just like on the MP version. "LBWS" Select "LBWS" Select Page 18 FT DX 9000MP/CONTEST DATA MANAGEMENT OPERATION MANUAL SPECTRUM SCOPE USING THE FIX (FIXED) MODE This feature is convenient when you want to monitor an entire amateur band. The starting point, located at the left edge of the screen, can be set via the Menu. Even if the screen span (bandwidth) is changed, the start frequency will not be changed. By watching the screen, you can move your operation to frequencies where interesting activity appears on the display. [. . . ] The menu mode will be reset, and the factory default configurations will come back. MNU key Page 44 FT DX 9000MP/CONTEST DATA MANAGEMENT OPERATION MANUAL USING THE MENU MODE EXPLANATION OF THE FUNCTION KEYS ON THE MENU MODE SCREEN [2/3. 5](LOAD) Press this key to download previously-used Menu settings from the CF card to the transceiver. [6/14]( ) This is the "down" key for scrolling through the menu mode list. The items also can be selected by rotating the Main Tunig knob. [3/5](SAVE) Press this key to save the current Menu settings to the CF card. [7/18]( ) This is the "up" key for scrolling through the menu mode list. When you have completed making all changes to the menu setting(s), press the [MNU] key for 2 seconds to lock in the changes. If you do not want to keep the changes, press the [MNU] key only momentarily; the radio will come back to the previous menu status that was present before you made the changes. [4/7]( ) Use this key to select the configuration value of the menu item. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE YAESU FTDX9000




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual YAESU FTDX9000 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.