Manual abstract: user guide VAISALA WHP25
Detailed instructions for use are in the User's Guide.
[. . . ] 20 Figure 11 WHP25 Main Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
List of Tables
Table 1 Table 2 Table 3 Manual Revisions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
2 ______________________________________________________ M210376en-A
Chapter 1 ___________________________________________ General Information
CHAPTER 1
GENERAL INFORMATION
This chapter provides general notes for the product.
About This Manual
This manual provides information for installing, operating, and maintaining WHP25 Mains Power Supply.
Contents of This Manual
This manual consists of the following chapters: - Chapter 1, General Information, provides general notes for the product. - Chapter 2, Product Overview, introduces the WHP25 Mains Power Supply features. [. . . ] - Always hold the boards by the edges and avoid touching the component contacts.
Warranty
For certain products Vaisala normally gives a limited one year warranty. Please observe that any such warranty may not be valid in case of damage due to normal wear and tear, exceptional operating conditions, negligent handling or installation, or unauthorized modifications. Please see the applicable supply contract or conditions of sale for details of the warranty for each product.
6 ______________________________________________________ M210376en-A
Chapter 2 ____________________________________________ Product Overview
CHAPTER 2
PRODUCT OVERVIEW
This chapter introduces the WHP25 Mains Power Supply features.
Introduction to WHP25 Mains Power Supply
WHP25 is a compact AC (Mains) Power Supply Unit intended for outdoor use. The unit is capable of delivering power, for example, to the WA25 Wind Set. The nominal input power of 230 VAC can be changed by jumpers between 100 VAC and 245 VAC (±10 %). The WHP25 unit provides two power outputs, namely 24. 0 VDC (max 5. 2 A) and 38. 0 VAC (max 0. 9 A). It is mountable to a Ø 100 mm standard pole mast.
VAISALA___________________________________________________________7
User's Guide ________________________________________________________
0212-184
Figure 1
WHP25 Mains Power Supply
The following numbers refer to Figure 1 above: 1 2 3 = Gland for AC (mains) input cable = Gland for optional power output cable = Gland for power output cable
8 ______________________________________________________ M210376en-A
Chapter 3 __________________________________________________ Installation
CHAPTER 3
INSTALLATION
This chapter provides you with information that is intended to help you install WHP25 Mains Power Supply.
Installation Procedure
Before installation, route the input (AC) power cable near the mast, which WHP25 Mains Power Supply will be mounted to. Make sure you selected a pole mast with a diameter from 99 to 105 mm for installation with the standard mounting clamp. Attach the unit to the mast at a suitable place with the provided accessories and the standard mounting clamp. Refer to Figure 2 on page 10.
VAISALA___________________________________________________________9
User's Guide ________________________________________________________
0212-185
Figure 2
Mounting WHP25 Mains Power Supply on a Pole Mast
The following numbers refer to Figure 2 above. = Enclosure = Slot screw M6, washer A6, spring washer B6, and nut M6 = Mounting clamp = Pole mast, diameter from 99 to 105 mm = Cable gland = Cable If the local voltage level is other than 230 VAC, reselect the voltage with the X2 and X3 jumpers located inside the WHP25 unit. For instructions how to set the jumpers for different input voltages, refer to Figure 4 on page 11.
WARNING
Improper jumper setting damages WHP25 Mains Power Supply.
CAUTION
Observe the instructions and warnings in the instruction label inside the unit, refer to Figure 4 on page 11.
10 _____________________________________________________ M210376en-A
Chapter 3 __________________________________________________ Installation
0212-186
Figure 3
Location of the WHP25 Jumpers
The following numbers refer to Figure 3 above. 1 2 3 = Plastic shield above the jumpers = Caution label = Fixing screw for the plastic shield
F1 X1
2AT
Primary
FUSES
8AT
Secondary
F2 X4
12345678
MAINS VOLTAGE
(X2, X3) Factory setting 230V 245V 38VAC 0. 9A ACout (RG13H) 24VDC 5. 2A DCout (WA25)
100V
X2
115V
200V
215V
ELN
X3
NOTE!Total wire resistance less than 0. 3 ohms recommended for WA25 systems.
MAINS INPUT 1. 0 - 2. 0 A
WARNING!5.
Instructions Label for the WHP25 Jumper Settings and Wiring
Make sure the AC (mains) voltage is disconnected. Enter the AC (mains) cable through the leftmost cable gland and connect the input wiring to the X1
VAISALA__________________________________________________________11
User's Guide ________________________________________________________
connector. To ease the wire connection the connector has spring loaded terminals. The wiring of the AC (mains) input to the X1 connector is instructed in Figure 4 on page 11. Refer to Figure 5 below for the location of the connectors and cable glands on the WHP25 unit. Tighten the input cable glands.
7.
0212-187
Figure 5
WHP25 Connectors and Glands
The following numbers refer to Figure 5 above. When using the standard power and signal cables ZZ45049 and ZZ45048, the connections are the following: 1. For power supply, connect the YEL, GRN, and PNK colored wires to the screw terminal #2 and the WHT, BRN, and GRY colored wires to the terminal #3. [. . . ] - How many failed (only one defect / other same or similar defects / several failures in one unit)?- Input power source type, voltage and list of other items (lighting, heaters, motors etc. ) that were connected to the same power output. Include a detailed return address with your preferred shipping method on the Problem Report. Pack the faulty product using an ESD protection bag of good quality with proper cushioning material in a strong box of adequate size. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE VAISALA WHP25
Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual VAISALA WHP25 will begin.