If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual VAISALA VERITEQ UNIVERSAL INPUT DATA RECORDER SERIES 4000. We hope that this VAISALA VERITEQ UNIVERSAL INPUT DATA RECORDER SERIES 4000 user guide will be useful to you.
Manual abstract: user guide VAISALA VERITEQ UNIVERSAL INPUT DATA RECORDER SERIES 4000DATASHEET
Detailed instructions for use are in the User's Guide.
[. . . ] www. vaisala. com
Vaisala Veriteq Universal Input Data Recorder Series 4000
Features/Benefits
Long-life 10-year battery and large onboard memory Single and multi-channel models with up to four input channels Easily set scaling and measurement units for recording Time-based digital recording in a range of sample intervals Multiple connectivity options USB, Ethernet, WiFi Optional vNet cradle for Ethernet or Power over Ethernet connectivity NIST-traceable calibration Two year limited warranty
The 4000 Series of data recorders are designed to interface with a wide range of transducers, transmitters, and sensors with a DC voltage or 0 - 20 mA current loop output. [. . . ] The optional browser-based viewLincTM system provides 24/7 multi-stage alarm notification, remote, realtime monitoring and gap-free data. Reports are customizable and can be exported to excel and PDF.
Technical data
General
Size Operating Range 85 x 59 x 26 mm (3. 4 x 2. 3 x 1") 76 g (2. 7 oz) -40 °C to +85 °C (-40 °F to +185 °F) and 0 %RH to 100 %RH (non-condensing) RS-232 serial USB Wifi module Ethernet and Power over Ethernet (vNet) Magnetic strips, 3M Dual LockTM fasteners Graphing & Reporting: Spectrum vLog (FDA/GxP regulated) Monitoring, Alarming, Reporting: viewLincTM Accuracy ±1 min. /month @ -25 °C to +70 °C (-13 °F to +158 °F) FCC Part 15 and CE EN 55022:2006 EN 61000-4-2:2001 EN 61000-4-3:2006 Internal 10-year lithium battery (Battery life specified with sample interval of 1 min. or longer)
Recording Span
SAmplE INTERVAl NumBER oF ChANNElS
Interfaces
10 seconds 1 minute 5 minutes 15 minutes 1 hour
1 13. 8 days 2. 7 months 1. 1 years 3. 4 years 13. 6 years
2 6. 9 days 1. 3 months 6. 9 months 1. 7 years 6. 8 years
3 4 4. 6 days 3. 4 days 27. 7 days 20. 8 days 4. 6 months 3. 4 months 1. 1 years 10. 4 months 4. 5 years 3. 4 years
Mounting PC Software
Current Loop and Voltage Inputs
INpuT TypE CuRRENT loop ANAlog VolTAgE
Internal Clock Electromagnetic Compatibility
0 to 20mA 0 to 5 VDC, 0 to 10 VDC 5. 5 A 0. 025 % F . S. (+77 °F) (+77 °F) Input Impedances 75 Ohms >1 MOhm Isolation One common per logger One common per logger Overload 40 mA max. (reverseProtection polarity protected) polarity protected)
Available Ranges Resolution Accuracy
Power Source
Channel Configurations
modEl 1, 2 oR 4 ChANNElS
4000-405 4000-40A 4000-40C
0 to 5 VDC 0 to 10 VDC 0 - 20 mA
Memory
Memory Type Data Sample Capacity Memory Modes Non-volatile EEROM 120, 000 12-bit samples User-selectable wrap (FIFO) or stop when memory is full. User-selectable (in 10 second intervals) from once every 10 seconds to once a day. or longer) Recording span depends upon sample interval selected and number of channels enabled. Please see table above.
Sampling Rates
Recording Span
For more information, visit www. vaisala. com or contact us at sales@vaisala. com
Ref. [. . . ] All specifications -- technical included -- are subject to change without notice. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE VAISALA VERITEQ UNIVERSAL INPUT DATA RECORDER SERIES 4000
Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual VAISALA VERITEQ UNIVERSAL INPUT DATA RECORDER SERIES 4000 will begin.