User manual VAISALA VERITEQ TEMPERATURE AND RH DATA RECORDER SERIES 2000 DATASHEET
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual VAISALA VERITEQ TEMPERATURE AND RH DATA RECORDER SERIES 2000. We hope that this VAISALA VERITEQ TEMPERATURE AND RH DATA RECORDER SERIES 2000 user guide will be useful to you.
Manual abstract: user guide VAISALA VERITEQ TEMPERATURE AND RH DATA RECORDER SERIES 2000DATASHEET
Detailed instructions for use are in the User's Guide.
[. . . ] www. vaisala. com
Vaisala Veriteq Temperature and RH Data Recorder Series 2000
particles, or conductivity. The 2000 recorder can include a Boolean channel for door switches or alarm contacts. [. . . ] Reports are customizable and can be exported to Excel®.
Features/Benefits
Industry-leading temperature and relative humidity measurement precision High accuracy, adjustable timebased digital recording Printed reports for any time period Extended 10-year long-life battery Ability to perform validation and continuous monitoring with the same model NIST-traceable, A2LA accredited calibration Superior alternative to chart recorders and hard-wired systems Integrated high-accuracy RH sensor
Technical Data
General
Size Interfaces Mounting PC Software 85 x 59 x 26mm (3. 4 x 2. 3 x 1") 76g (2. 7 oz. ) RS-232 serial, USB, WiFi, Ethernet and Power over Ethernet (vNet) Magnetic strips; 3M Dual LockTM fasteners Graphing & Reporting: Spectrum, vLog (FDA/GxP regulated) Monitoring, Alarming, Reporting: viewLinc OPC Server to add loggers to an existing OPC-compatible monitoring system. Accuracy ± 1 min. /month@ -25 °C to +70 °C (-13 °F to +158 °F) FCC Part 15 and CE, EN 55022:2006, EN 61000-4-2:2001, EN 61000-4-3:2006 Internal 10-year lithium battery (Battery life specified with sample interval of 1 min. or longer)
Internal Clock Electromagnetic Compatibility Power Source
Memory
Sample Capacity Memory Type Memory Modes 122, 197 12-bit samples Non-volatile EEROM User-selectable wrap (FIFO) or stop when memory is full. Sampling Rates User-selectable (in 10 second intervals) from once every 10 seconds to once a day. or longer)
Current Loop and Voltage Inputs
INpuT TypE CuRRENT Loop ANALog VoLTAgE
Available Ranges 0 to 22 mA 0 to 5 VDC, 0 to 10 VDC Resolution 5. 5 A 0. 025 % F . S. Accuracy ±0. 15 % F at +25 °C (+77 °F) ±0. 15 % F at +25 °C (+77 °F) . S. Input Impedances 75 Ohms* >1 MOhm Isolation One common per logger One common per logger Overload 40 mA max. (reverseProtection polarity protected) polarity protected)
Internal Sensors
INTERNAL TEMpERATuRE sENsoR
Channel Configuration and Recording Span
ChANNEL TypEs ModEL NuMBER
Calibrated Measurement -25 °C to +70 °C Range1 (-13 °F to +158 °F) Operating Range -35 °C to +85 °C (-31 °F to +185 °F) Initial Accuracy2 ± 0. 10° C over +20 °C to +30 °C (± 0. 18° F over +68 °F to +86 °F) ± 0. 15° C over -25 °C to +70 °C (± 0. 27 °F over -13 °F to +158 °F) One Year Accuracy3 ± 0. 15 °C over +20 °C to +30 °C (± 0. 27 °F over +68 °F to +86 °F) ± 0. 25 °C over -25 °C to +70 °C (± 0. 45 °F over -13 °F to +158 °F) Resolution 0. 02 °C at +25 °C (0. 04 ° F at +77 °F)
INTERNAL Rh sENsoR
2000-3CR 2000-35R 2000-3AR 2000-4BR
CH 1 Temperature Temperature Temperature Temperature
CH 2 Relative Humidity Relative Humidity Relative Humidity Relative Humidity
CH 3 Current 4 to 20 mA Voltage 0 to 5 VDC Voltage 0 to 10 VDC Boolean
CH 4
Boolean
NuMBER oF ChANNELs ENABLEd**
Calibrated Measurement Range1 Operating Range Initial Accuracy2
One Year Accuracy
3
Resolution
1
45 %RH at +10 °C (+50 °F) 10 %RH to 80 %RH at +25 °C (+77 °F) 45 %RH at +45 °C (+113 °F) 0 %RH to 100 %RH (non-condensing) ± 1 %RH over 10 %RH to 90 %RH at +20 °C to +30 °C (+68 °F to +86 °F) ± 2 %RH over 10 %RH to 90 %RH at -20 °C to +70 °C (-4 °F to +158 °F) ± 2 %RH over 10 %RH to 90 %RH at +20 °C to +30° C (+68 °F to +86 °F) ± 3 %RH over 10 %RH to 90 %RH at -20 °C to +70 °C (-4 °F to +158 °F) 0. 05 %RH
sAMpLE INTERVAL
10 Seconds 1 Minute 5 Minutes 15 Minutes 1 Hour
1 14. 1 Days 2. 8 Months 1. 2 Years 3. 5 Years 13. 9 Years
2 7. 1 Days 1. 4 Months 7. 1 Months 1. 7 Years 7. 0 Years
3 4 4. 7 Days 3. 5 Days 23. 8 Days 21. 2 Days 4. 7 Months 3. 5 Months 1. 2 Years 10. 6 Months 4. 6 Years 3. 5 Years
* Termination resistance plus approximately 0. 4 volt drop through a protection diode. ** Temperature channel must be enabled when the RH channel is enabled.
2
3
Custom calibration points available upon request including full ICH coverage. Initial accuracy includes all known influence quantities present at the time of calibration including calibration uncertainty, mathematical fit, data logger resolution, hysteresis and reproducibility. [. . . ] The reproduction, transfer, distribution or storage of information contained in this brochure in any form without the prior written consent of Vaisala is strictly prohibited. All specifications -- technical included -- are subject to change without notice. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE VAISALA VERITEQ TEMPERATURE AND RH DATA RECORDER SERIES 2000
Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual VAISALA VERITEQ TEMPERATURE AND RH DATA RECORDER SERIES 2000 will begin.