[. . . ] USER'S GUIDE
Vaisala SPECTRACAP® Oxygen Transmitter OMT364
M210862EN-A
PUBLISHED BY Vaisala Oyj P. O. Box 26 FI-00421 Helsinki Finland Phone (int. ): Fax: +358 9 8949 1 +358 9 8949 2227
Visit our Internet pages at http://www. vaisala. com/ © Vaisala 2009 No part of this manual may be reproduced in any form or by any means, electronic or mechanical (including photocopying), nor may its contents be communicated to a third party without prior written permission of the copyright holder. Please observe that this manual does not create any legally binding obligations for Vaisala towards the customer or end user. All legally binding commitments and agreements are included exclusively in the applicable supply contract or Conditions of Sale.
________________________________________________________________________________
Table of Contents
CHAPTER 1
GENERAL INFORMATION . [. . . ] > Prints information about the device Prints information even in POLL mode
82 ___________________________________________________________________M210862EN-A
Chapter 5 ________________________________________________________________ Operation
Show Laser Temperature Controller Status Command (LTC)
This command displays the status of the laser temperature controller object and related variables. Syntax: LTC<cr> Example:
>ltc *** LASER TEMPERATURE CONTROLLER (LTC) *** Mode : ON State : TEMP_OK Set Temp (C) : 29. 074 Temp (C) : 29. 073 Diff (C) : -0. 001 PID Output : -773 DAC Output : 29227
Show Output Status Command (OUT)
This command displays the status of the analog output controller object and related variables. Syntax: OUT<cr> Example:
>out *** ANALOG OUTPUT (OUT) *** Mode : NORMAL State : NORMAL Oxygen (%) : 0. 00 Current (mA) : 3. 00 DAC Output : 50000 GI OI NONFATALI (mA) FATALI (mA) I4 OUTMAX02 (%) OUTMIN02 (%) : : : : : : : 1. 0000 0. 0000 3. 000 2. 000 1 20. 000 0. 000
VAISALA _______________________________________________________________________ 83
User's Guide ______________________________________________________________________
Show All Modifiable Parameter Values (PARAM)
This command displays the current values of all parameters that can be set by the user. Syntax: PARAM<cr> Example:
>param Customer Interface--------------SERI : 19200 8 NONE 1 ECHO : ON SMODE : STOP Service Interface---------------SERI : 115200 8 NONE 1 ECHO : ON SMODE : STOP Common Serial parameters--------ADDR :0 INTV :1S FORM : F0 Analog Output--------------------OUTMINO2 (%) : 0. 000 OUTMAXO2 (%) : 25. 000 I4 :1 NONFATALI (mA) : 3. 000 FATALI (mA) : 3. 000 Relay Output---------------------RELAY_MODE : FAULT_ALARM LO POINT (%02) : 10. 0 HI POINT (%02) : 11. 0 Measurement parameters-----------INSTALLATION : Process measurement PRESSURE(bar) : 1. 000 H2O (g/m3) : 50 CO2 (vol-%) : 20
Measure Signal Level Command (SIL)
Test signal level. This command compares the laser signal strength to its original strength. The original strength is the signal level the laser had when the
84 ___________________________________________________________________M210862EN-A
Chapter 5 ________________________________________________________________ Operation
factory calibration was made. With this command it is possible to measure contamination of the optics. Syntax: SIL<cr> Example:
>sil Signal level is 100% compared to signal level at factory
Signal Level Display Function (Sil)
When the signal level display function Sil is selected the laser signal strength is compared to its original strength (displayed as 0 . . . The original strength is the signal level the laser had when the factory calibration was made. With this function it is possible to measure contamination of the optics.
0511-076
0511-077
Show Statistical Information Command (STATS)
This command displays statistical information. Syntax: STATS<cr>
VAISALA _______________________________________________________________________ 85
User's Guide ______________________________________________________________________
Example:
>stats All cleared Uptime (h) Resets O2 max O2 min Tg max Tg min Ti max Ti min : 2006-01-18 13:40:04 : 140 :7 : 21. 06 : 4. 91 : 29. 71 : 23. 39 : 32. 53 : 24. 55
Show Status of Subfunctions Command (STATUS)
This command displays modes and status of all sub functions. Syntax: STATUS<cr> Example:
>status Sub function modes and states: *** LASER TEMPERATURE CONTROLLER (LTC) *** Mode : ON State : TEMP_OK *** OXYGEN MEASUREMENT (MEA) *** Mode : MODE2 State : PEAK_LOCKED Run Time Func. : OFF *** ANALOG OUTPUT (OUT) *** Mode : NORMAL State : NORMAL *** ERROR CONTROL (ERR) *** Mode : ON State : NO ERRORS *** CUSTOMER INTERFACE (SCI2) ***: Mode : STOP *** SERVICE INTERFACE (SCI1) ***: Mode : STOP *** DISPLAY BOARD (DB) *** Mode : NORMAL State : NORMAL >
86 ___________________________________________________________________M210862EN-A
Chapter 5 ________________________________________________________________ Operation
Show Product Name and Software Version Command (VERS)
This command prints out the device name and the software version. Syntax: VERS<cr> Example:
>vers OMT300 / 1. 02
Memory Handling Save Parameters Command (SAVE)
NOTE
Remember to use the SAVE command whenever you make any changes to any of the parameters, otherwise the changes might be lost. Syntax: SAVE<cr> Example:
>save EEPROM EEPROM EEPROM EEPROM (basic) saved successfully (op) saved successfully (op_log1) saved successfully (op_log2) saved successfully
VAISALA _______________________________________________________________________ 87
User's Guide ______________________________________________________________________
Resetting the Transmitter Reset Command (RESET)
This command resets the transmitter. This command has exactly the same effect as toggling power to the transmitter. Syntax: RESET<cr> Example:
>reset Reseting. . .
OMT300 - Version STD 1. 02 Vaisala Oyj, 2004-2005 . . .
Reset Function (Off)
When the reset function Off is selected the transmitter stops all operations and performs a reset. To reset the transmitter, select function Off from the menu and press Ent. New measurement starts after the self-test is completed and the oxygen absorption line is found.
0511-106
0511-107
88 ___________________________________________________________________M210862EN-A
Chapter 6 _____________________________________________ Setting Environmental Parameters
CHAPTER 6
SETTING ENVIRONMENTAL PARAMETERS
Environmental Parameter Compensations
The oxygen measurement of OMT364 is somewhat affected by the temperature, pressure and background gas of the measuring environment. Because of these phenomena, OMT364 has built-in compensations for the temperature and pressure of the operating environment as well as for the water and CO2 content of the background gas. To achieve the most accurate measurement, the compensations should be enabled. The compensated output corresponds to "% O2" in the actual environment (T, P, humidity, and CO2). [. . . ] Syntax: ERR<cr>
VAISALA ______________________________________________________________________ 145
User's Guide ______________________________________________________________________
Example:
>err *** ERROR CONTROL (ERR) *** Mode : ON State : WARNING ERRORS: WARNING : WATCHDOG RESET OCCURRED >
Show Error Log (ERRL)
This command displays the events in the error log. Syntax: ERRL<cr> Example:
>errl T(h)T(ms)EventError 3043991ACT NO MEASUREMENT RESULTS 30461191ACT LASER TEMPERATURE NOT REACHED 30478691DEACTLASER TEMPERATURE NOT REACHED 30499091DEACTDEACTNO MEASUREMENT RESULTS >
Show Detected Errors (ERRS)
This command displays all errors currently active in the device. Syntax: ERRS<cr> Example:
>errs ERROR: LOW SIGNAL ERROR: FP SLOPE FAILURE >
Show Error Table (ERRT)
This command displays the error table. Syntax: ERRT<cr>
146 __________________________________________________________________M210862EN-A
Chapter 10 __________________________________________________________ Troubleshooting
Example:
>errt # :St :Cnt 1:OFF: 2:OFF: . . . [. . . ]