User manual VAISALA MMT330
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual VAISALA MMT330. We hope that this VAISALA MMT330 user guide will be useful to you.
You may also download the following manuals related to this product:
VAISALA MMT330 QUICK REFERENCE GUIDE (818 ko)
VAISALA MMT330 QUICK REFERENCE GUIDE (818 ko)
VAISALA MMT330 QUICK REFERENCE GUIDE (818 ko)
VAISALA MMT330 QUICK REFERENCE GUIDE (818 ko)
VAISALA MMT330 QUICK REFERENCE GUIDE (818 ko)
VAISALA MMT330 QUICK REFERENCE GUIDE (818 ko)
VAISALA MMT330 QUICK REFERENCE GUIDE (818 ko)
VAISALA MMT330 QUICK REFERENCE GUIDE (818 ko)
VAISALA MMT330 DATASHEET (636 ko)
VAISALA MMT330 QUICK REFERENCE GUIDE (818 ko)
Manual abstract: user guide VAISALA MMT330
Detailed instructions for use are in the User's Guide.
[. . . ] USER'S GUIDE
Vaisala HUMICAP® Moisture and Temperature Transmitter for Oil MMT330
M210733EN-E
PUBLISHED BY Vaisala Oyj P. O. Box 26 FI-00421 Helsinki Finland Phone (int. ): +358 9 8949 1 Fax: +358 9 8949 2227
Visit our Internet pages at http://www. vaisala. com/ © Vaisala 2009 No part of this manual may be reproduced in any form or by any means, electronic or mechanical (including photocopying), nor may its contents be communicated to a third party without prior written permission of the copyright holder. Please observe that this manual does not create any legally binding obligations for Vaisala towards the customer or end user. All legally binding commitments and agreements are included exclusively in the applicable supply contract or Conditions of Sale.
________________________________________________________________________________
Table of Contents
CHAPTER 1
GENERAL INFORMATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] The data that is stored in the logger's memory is timestamped using the logger's clock. When date and time are set on the transmitter, they are stored to the transmitter's memory as an offset from the time on the logger's clock. When browsing the stored data, the time offset is applied to the timestamps shown in the graphical history, and data outputted from the serial port. The timestamps in the data logger's memory remain as they were originally stored. You can compensate for the clock drift (less than ±2 min/year) by setting the time on the transmitter. You can set the time by using the keypad/display or the serial commands.
0706-068
Figure 37
Data Logger Module
VAISALA _______________________________________________________________________ 63
User's Guide ______________________________________________________________________
The following numbers refer to Figure 37 on page 63: 1 2 = = Flat cable pins Battery
After a reset or a power up, it will usually take at least 10 seconds before the data logger module is initialized. The real time clock and the data logging and reading functions are not available before the initialization is complete. The indicator LED on the module will blink green during normal operation. The transmitter will also indicate the problem by activating the "Add-on module connection failure" error. If the module is not operating correctly, the transmitter must be sent to Vaisala for maintenance. The data logger module must be installed at the factory (when ordering the transmitter), or by a Vaisala Service Center. When the module requires a new battery, the transmitter must be sent to Vaisala for maintenance.
64 __________________________________________________________________ M210733EN-E
Chapter 3 _______________________________________________________________ Installation
8-Pin Connector
0503-026
Figure 38 Table 8
PIN/Terminal Wire 1 2 3 4 5 6 7 8 White Brown
Wiring of Optional 8-Pin Connector Wiring of 8-Pin Connector
Serial Signal RS-232 (EIA-232) Data out TX (serial GND) Supply Supply + Data in RX Cable shield Analog Signal RS-485 (EIA-485) A (serial GND) Signal GND (for both channels) Ch 2+ Ch 1 + Supply Supply Supply + Supply + B Cable shield Cable shield
Green Yellow Grey Pink Blue Shield/Red
VAISALA _______________________________________________________________________ 65
User's Guide ______________________________________________________________________
This page intentionally left blank.
66 __________________________________________________________________ M210733EN-E
Chapter 4 ________________________________________________________________ Operation
CHAPTER 4
OPERATION
This chapter contains information that is needed to operate this product.
Getting Started
Within a few seconds after power-up the led on the cover of the transmitter is lit continuously indicating normal operation. When using the optional display and turning the transmitter on the first time, the language selection menu window opens. Select the language with arrow buttons and press the SELECT button (the left-hand button).
Display/Keypad (Optional)
Basic Display
Display shows you the measurement values of the selected quantities in the selected units. 3 quantities for the numerical basic display (see section Changing Quantities and Units on page 92. )
0706-046
Figure 39
Basic Display
The following numbers refer to Figure 39 above: 1 = The Info shorcut button, see section Device Information on page 99.
VAISALA _______________________________________________________________________ 67
User's Guide ______________________________________________________________________
The following numbers refer to Figure 39 above: 2 3 = = The Graph shortcut button, see section Graphic History on page 68. Quantities selected for display
NOTE
From any view, a four-second press on the right-hand function button takes you directly to the basic display.
Graphic History
The graphical display shows the data trend or min/max graph of the selected quantities, one at a time. The graph is updated automatically while measuring.
0706-047
Figure 40
Graphical Display
Trend graph: Shows you a curve of average values. Max/min graph: Shows you the minimum and maximum values in a form of curve. Table 9 Periods for Trend and Max/Min Calculations
Period for Trend/Max/Min Calculations (Resolution) 20 minutes 10 seconds 3 hours 90 seconds 1 day 12 minutes 10 days 2 hours 2 months 12 hours 1 year 3 days 4 year* 12 days * Shows the maximum logging period of the data logger module (available when data logger module is installed)
Observation Period
68 __________________________________________________________________ M210733EN-E
Chapter 4 ________________________________________________________________ Operation
Use the following functions in the graphical display: - Press the NEXT button to change between the trend graph and max/min graph for the quantities selected for display. - Press the arrow buttons move the cursor (vertical bar) along the time axis. The numerical value at the cursor position is shown at the left upper corner. The right upper corner shows the time from the present to the chosen moment (without the logger module), or the date and time at the cursor position (when the logger module is installed). [. . . ] 2004-05-21
142 _________________________________________________________________ M210733EN-E
Chapter 8 ____________________________________________________________ Technical data
CHAPTER 8
TECHNICAL DATA
This chapter provides the technical data of the product.
Specifications
Measured Values
Water activity Measurement range 0 . . . 1 aw Accuracy (including non-linearity, hysteresis and repeatability) 0 . . . 1. 0 ±0. 03 Response time (90%) at +20 °C in still oil (with stainless steel filter) 10 min. Sensor HUMICAP®
Performance
Temperature
Measurement range MMT342 MMT347 MMT348 Accuracy at +20 °C (+68 °F) -40 . . . [. . . ]