User manual VAISALA MI70 DATASHEET

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual VAISALA MI70. We hope that this VAISALA MI70 user guide will be useful to you.


VAISALA MI70 DATASHEET: Download the complete user guide (288 Ko)

Manual abstract: user guide VAISALA MI70DATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] www. vaisala. com The handheld Vaisala Measurement Indicator MI70 Features/Benefits: Wide selection of measurement probes ­ the HM70, ­ DM70, ­ MM70 and ­ GM70 series Multiprobe operation combine any two probes May be connected to certain Vaisala's fixed transmitters User-friendly interface Multiple language options Suitable for field checking of fixed instruments The MI70 connected to a GM70 diffusion sampling probe measures CO2 concentration. [. . . ] The MI70's user-friendly user interface operates with menus and keypads to change settings, logging and display preferences. One or 2 probes at a time The MI70 indicator has two cable ports, by which a combination of any two probes (or transmitters) can be connected to it, at a time. For example, a humidity and temperature probe could be connected to the one port, and a CO2 probe to the other. The indicator can display the measurements made by both probes, so humidity, temperature and CO2 data could be displayed simultaneously. Up to three measurement parameters can be selected by the user, and displayed at the same time. The graphic display shows the stabilization of measurement and process trends. Multiple language options The MI70 is programmed with a variety of languages: English, German, French, Finnish, Spanish, Swedish, Chinese, Russian and Japanese. Optional connection to PC The optional MI70 Link Windows® software and the USB connection cable form a practical tool for transferring logged data as well as real time measurement data from the MI70 to a PC. Technical data MI70 measurement indicator, general English, Chinese, French, Spanish, German, Russian, Japanese, Swedish, Finnish Display LCD with backlight, graphic trend display of any parameter, character height up to 16 mm Max. of probes 2 Power supply Rechargeable NiMH battery pack with AC-adapter or 4xAA-size alkalines, type IEC LR6 Resolution 0. 01 %RH, 0. 01 °C/°F, 0. 01 hPa, 0. 01 aw, 0. 01 ppm/% CO2 Analog output (w/ accessory cable) 0 . . . 1 VDC Output resolution 0. 6 mV PC interface MI70 Link software with USB or serial port cable Data logging capacity 2700 points Logging interval 1 s . . . memory full Alarm audible alarm function Operating temperature range -10 . . . +104 °F) Operating humidity range non-condensing Housing classification IP54 Housing materials ABS/PC blend Weight (indicator only) 400 g Battery operation time (depends on chosen probe/probes) Continuous use (one probe of HM70, DM70 and MM70 series) 48 h typical at +20 °C (+68 °F) Continuous use (GM70 handle) better than 8 h at +20 °C (+68 °F) Continuous use (GM70 pump) better than 5 h at +20 °C (+68 °F) Data logging use up to a month, depending on logging interval Environmental settings e. g. pressure user definable (and temperature, if not incl. ) Menu languages Measurement probes for the MI70 HM70 Series Humidity and Temperature probes HMP75(B) General purpose probe HMP76(B) Long, stainless steel probe HMP77(B) Small probe, with 5 m cable DM70 Series dewpoint probes DMP74A, DMP74B Pressure tight probes for dry air measurements DMP74C Probe for SF6 gas measurements MM70 Moisture in oil probe MMP78 Pressure tight, stainless steel probe GM70 Carbon Dioxide probes GMH70 Handle for probe for diffusion sampling GM70PUMP Pump for probe for pump aspirated sampling For full specifications of the measurement probes see relevant brochures/User's Guides (use the relevant order form to define ordered probe) Accessories Carrying cases for MI70 and HMP75/77, one DM70, or GM70 probe (of black ABS) for MI70 and HMP75/76, two DM70 probes, or MM70 probe (of aluminium) Transmitter connection cables for MMT/HMT330, HMT100, DMT340, PTB330, PTU300 Series HMD/W 60/70 Series DMT242 DMT142 DMT152, MMT162 MMT/HMT310 Series, GMP343 GMT220, GMM220, GMW/D20 HMP155 MI70 Link software with USB cable MI70 Link software with serial port cable Analog output cable 10 m (32. 81 ft) extension cable for probe Battery, NiMH 4. 8 V MI70CASE MI70CASE2 Electromagnetic compatibility EN 61326-1, Portable Equipment 211339 HMA6070 27160ZZ 211917ZZ 219980 DRW216050 GMA70 221801 219687 MI70LINK 27168ZZ 213107SP 26755 For more information, visit www. vaisala. com or contact us at sales@vaisala. com Ref. [. . . ] All specifications -- technical included -- are subject to change without notice. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE VAISALA MI70




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual VAISALA MI70 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.