HMP50 Miniature Humidity and Temperature Probe for OEM Applications
The HMP50 features good measurement performance in a small, rugged and simple probe.
Features/Benefits
Miniature-size humidity transmitter Very low power consumption - well suitable for batterypowered applications Short power-up time Measurement range 0 . . . [. . . ] The sensor is protected by a membrane filter and plastic grid, or optionally a stainless steel filter.
Technical data
Performance
relative humidity
Inputs and outputs
0 . . . 98 %RH ±3 %RH ±5 %RH ±2 %RH over 2 years Operating voltage for 0 . . . 5 VDC output model Current consumption Settling time at power-up Outputs (equals 0 . . . 1/2. 5/5VDC
Measurement range Typical accuracy at +20 °C (+68 °F) 0 . . . 98 %RH Stability Temperature dependence
RLmin 10kohm RLmin 50kohm
Cable colors. +60 °C
temperature (optional)
Measurement range Typical accuracy at +20 °C Temperature dependence
-10 . . . +140 °F) ±0. 6 °C (±1. 1 °F)
Mechanics
Body material Grid/filter material Cable material Housing classification Body thread Grid thread Cable connector Cable lengths Weight chrome coated aluminium chrome coated ABS plastic polyurethane IP65 M12x1 / 10 mm M11x1 / 5 mm 4-pin M8 (IEC 60947-5-2) 0. 3 and 3 m 25 g (with 0. 3 m cable)
Options and accessories
Vaisala INTERCAP® sensor Vaisala INTERCAP® sensor with membrane Sensor protection plastic grid membrane filter stainless steel sintered filter Current output converter kit Plastic M12 installation nuts, pair Connection cable M8 0. 3 m 3m 15778HM 15872HM DRW010522 DRW010525 HM46670SP 26182HM 18350SP HMP50Z032 HMP50Z300
Operating environment
Environmental temperature operating storage Environmental operating RH Electromagnetic compatibility -10 . . . 100%RH Complies with EMC standard EN61326-1, Generic Environment