User manual VAISALA DM70

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual VAISALA DM70. We hope that this VAISALA DM70 user guide will be useful to you.


VAISALA DM70 : Download the complete user guide (1587 Ko)

You may also download the following manuals related to this product:

   VAISALA DM70 (1879 ko)
   VAISALA DM70 DATASHEET (309 ko)
   VAISALA DM70 DATASHEET (286 ko)

Manual abstract: user guide VAISALA DM70

Detailed instructions for use are in the User's Guide.

[. . . ] USER'S GUIDE Vaisala DRYCAP® Hand-Held Dewpoint Meter DM70 M010091EN-F PUBLISHED BY Vaisala Oyj P. O. Box 26 FIN-00421 Helsinki Finland Phone (int. ): +358 9 8949 1 Fax: +358 9 8949 2227 Visit our Internet pages at http://www. vaisala. com/ © Vaisala 2007 No part of this manual may be reproduced in any form or by any means, electronic or mechanical (including photocopying), nor may its contents be communicated to a third party without prior written permission of the copyright holder. The contents are subject to change without prior notice. Please observe that this manual does not create any legally binding obligations for Vaisala towards the customer or end user. All legally binding commitments and agreements are included exclusively in the applicable supply contract or Conditions of Sale. ________________________________________________________________________________ Table of Contents CHAPTER 1 GENERAL INFORMATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] It indicates the pressure difference between the normal atmospheric pressure and the actual process pressure. It indicates the pressure difference between the normal atmospheric pressure and the actual process pressure. Ppsia: Absolute pressure is given in the unit of psi. To set the values, follow the instructions below: 1. The default unit is Set. To set the ambient pressure value, press Set the value using the the pressure value, press OK. buttons. To save the value, press Exit. 6. To return to the basic display, press 36 __________________________________________________________________ M010091EN-F Chapter 5 _____________________________________________________________ User Interface Settings Menu User Interface 0403-038 Figure 14 User Interface Language You can select any of the following languages for the user interface: English, Finnish, Chinese, Russian, Japanese, Swedish, French, German, or Spanish. . User interface and then press Set. Select Language and press Then select the desired language and press To return to the basic display, press Exit. Select. If you accidentally selected a language you do not want, follow the instructions below: 1. Return to the basic display by pressing the rightmost the basic display appears. Go to the Language selection menu by pressing first then the button in the middle. until and again and finally press again VAISALA _______________________________________________________________________ 37 USER'S GUIDE____________________________________________________________________ Automatic Power Off As a default, the power in DM70 is automatically turned off after 15 minutes of inactivity. The inactivity settings can be changed to 60 minutes or completely turned off. Open. User interface and press Select Auto power off and press Select the inactivity time and press To return to the basic display, press Program Shortcut Keys As a default, the three shortcut keys refer to Graphic, Hold/Save, and Start/S functions. You can change any of the shortcut keys to refer to functions that better suit your needs. Open. User interface and press Select Program shortcut keys and then press Start. If you want to replace the Hold/Save with the auto-calibration function, select AutoCal with the arrow buttons and then press Select. To return to the basic display, press Exit 7. 38 __________________________________________________________________ M010091EN-F Chapter 5 _____________________________________________________________ User Interface 0403-039 Figure 15 Hold/Save Replaced by Auto Cal Button Tones and Backlight You can turn on or off the sound effects for the buttons and the back light. Open. Select User interface and press To turn on or off the sound effect, select Key Click and then On/Off. press To turn on or off the backlight, select Backlight on key and press On/Off. To return to the basic display, press Exit. Date and Time As a default, the time format is based on the 24-hour clock. For correct time and date in the recorded data files, follow the instructions below: 1. Open. VAISALA _______________________________________________________________________ 39 USER'S GUIDE____________________________________________________________________ 3. 4. Select Date and time and press . For the desired date, select Date and then press Set. To change the date format, select from the alternatives and press Select. [. . . ] Exit. VAISALA _______________________________________________________________________ 77 USER'S GUIDE____________________________________________________________________ Vaisala Service Centers 78 __________________________________________________________________ M010091EN-F Chapter 10 ___________________________________De-commissioning, Dismantling, and Disposal CHAPTER 10 DE-COMMISSIONING, DISMANTLING, AND DISPOSAL WARNING Contaminated parts can be detrimental to health and environment. Before beginning to work, find out whether any of the parts especially the probe, filter, or sampling cell - have been contaminated (radioactive, toxic, caustic, or contains a biological hazard, etc. ) during the measurement process. Adhere to the relevant regulations and take the necessary precautions when handling contaminated parts. Contaminated components, if any, must be decontaminated according to the relevant national regulations. The battery packs and/or alkaline batteries must be removed as described in section Installing and Removing the Battery Pack on page 13 (MI70) and in section Changing the Battery on page 57 (DSS70A). [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE VAISALA DM70




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual VAISALA DM70 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.