User manual TJERNLUND SS2G SIDESHOT (DISCONTINUED) 8504075 REV 1 1198

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual TJERNLUND SS2G SIDESHOT (DISCONTINUED) 8504075 REV 1 1198. We hope that this TJERNLUND SS2G SIDESHOT (DISCONTINUED) 8504075 REV 1 1198 user guide will be useful to you.


TJERNLUND SS2G SIDESHOT (DISCONTINUED) 8504075 REV 1 1198 : Download the complete user guide (377 Ko)

Manual abstract: user guide TJERNLUND SS2G SIDESHOT (DISCONTINUED) 8504075 REV 1 1198

Detailed instructions for use are in the User's Guide.

[. . . ] 1 11/98 TJERNLUND PRODUCTS, INC. 1601 Ninth Street · White Bear Lake, MN 55110-6794 PHONE (800) 255-4208 · (651) 426-2993 · FAX (651) 426-9547 Visit our web site · www. tjernlund. com 56826 MODEL SS2G INSTALLATION INSTRUCTIONS !Recognize this symbol as an indication of important safety information! OWNER INSTRUCTIONS, DO NOT DESTROY NOTE: MAXIMUM FLUE GAS TEMPERATURES MUST NOT EXCEED 650oF. THESE INSTRUCTIONS ARE INTENDED AS AN AID TO QUALIFIED, LICENSED SERVICE PERSONNEL FOR PROPER INSTALLATION, ADJUSTMENT AND OPERATION OF THIS UNIT. READ THESE INSTRUCTIONS THOROUGHLY BEFORE ATTEMPTING INSTALLATION OR OPERATION. FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN IMPROPER INSTALLATION, ADJUSTMENT, SERVICE OR MAINTENANCE POSSIBLY RESULTING IN FIRE, ELECTRICAL SHOCK, CARBON MONOXIDE POISONING, EXPLOSION, PERSONAL INJURY OR PROPERTY DAMAGE. DO NOT DESTROY. [. . . ] Note: We recommend the use of flexible conduit for connections to the SS2G to allow for slide out servicing feature of venter assembly. The electrical contact ratings for the diaphragm Fan Proving Switch and High Limit are as follows: FAN PROVING SWITCH 3 Amps (full load) at 24 VAC 36 Amps (locked rotor) at 24 VAC HIGH LIMIT 10 Amps (full load) at 24 VAC 60 Amps (locked rotor) at 24 VAC The Fan Proving Switch and High Limit are not suitable for loads which exceed the above limits. The installer must ensure that all electrical connections between the appliance and Power Venter are tight and that all wires are positioned and secured so they cannot come in contact with high temperature locations. The installer must ensure that the internal appliance transformer is rated no lower than 40VA. The installer must ensure that the heat anticipator in the comfort thermostat is adjusted according to the thermostat manufacturer's recommendation. All wiring must be in compliance with local codes or in their absence, with the latest Edition of the National Electric Code (NFPA #70). Disconnect 115V power before attempting to wire the Power Venter to the appliance. Power may be disconnected by means of the appliance circuit breaker/fuse. NOTES: While it is impossible to include every possible wiring scenario, the following diagrams represent the most common. If wiring the SS2G to an appliance not equipped with the controls shown on the following diagrams, determine which terminals of the gas valve are considered "HOT" and "COMMON" and follow the steps on page 9. When wiring Power Venter to the gas valve wire all thermostats, zones, circulators and limits as would normally be done if venting into a chimney. NAT T PROCEDURES WIRING SS2G WITH SINGLE ZONE THERMOSTAT SEQUENCE OF OPERATION WITH SINGLE ZONE THERMOSTAT: Adjust the furnace thermostat to call for heat. If you are unable to detect a slight delay, contact Tjernlund Products, Inc. When the fan proving switch closes, the furnace combustion relay is energized. Normal combustion sequence for the furnace begins: induced draft furnace blower starts, its proving switch makes energizing ignition control and/or gas valve. DO NOT OPERATE THE FURNACE WITHOUT THE FAN PROVING SWITCH WIRED INTO THE 24V FURNACE CIRCUIT!NOTE: When Power Venter is interlocked with a thermostat wire all zones, circulators and limits as would normally be done if venting into a chimney. If you are unable to wire the SS2G as outlined in these instructions, call Tjernlund's Customer Service Department toll free at 1-800-255-4208 for assistance. WIRING SS2G WITH THERMOSTAT SS2G WIRED TO 24V GAS VALVE SS2 SEQUENCE OF OPERATION WIRED TO GAS VALVE: As the thermostat/aquastat senses a need for heat, the internal switch of the thermostat/aquastat will close. The Switch closure completes the 24V electrical circuit to the internal controls of the appliance. Before the 24V signal reaches the appliance gas valve, it is interrupted by the Power Venter Relay/Timer and Fan Proving Switch. When the Power Venter Relay/Timer receives the 24V signal, the contact side closes completing the 115V circuit to the Power Venter motor. [. . . ] Date of original installation and dates any service work was performed. warrants the components of the SideShot for two years from date of installation. This warranty does not cover normal maintenance, transportation or installation charges for replacement parts or any other service calls or repairs. This warranty DOES NOT cover the complete SS2G if it is operative, except for the defective part. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TJERNLUND SS2G SIDESHOT (DISCONTINUED) 8504075 REV 1 1198




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual TJERNLUND SS2G SIDESHOT (DISCONTINUED) 8504075 REV 1 1198 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.