User manual TJERNLUND PAI-3,4,5,6,7 COMMERCIAL COMBUSTION AIR IN-FORCER 8504036 REV A 0501

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual TJERNLUND PAI-3,4,5,6,7 COMMERCIAL COMBUSTION AIR IN-FORCER 8504036 REV A 0501. We hope that this TJERNLUND PAI-3,4,5,6,7 COMMERCIAL COMBUSTION AIR IN-FORCER 8504036 REV A 0501 user guide will be useful to you.


TJERNLUND PAI-3,4,5,6,7 COMMERCIAL COMBUSTION AIR IN-FORCER 8504036 REV A 0501 : Download the complete user guide (1088 Ko)

Manual abstract: user guide TJERNLUND PAI-3,4,5,6,7 COMMERCIAL COMBUSTION AIR IN-FORCER 8504036 REV A 0501

Detailed instructions for use are in the User's Guide.

[. . . ] A 05/01 TJERNLUND PRODUCTS, INC. 1601 Ninth Street · White Bear Lake, MN 55110-6794 PHONE (800) 255-4208 · (651) 426-2993 · FAX (651) 426-9547 Visit our web site · www. tjernlund. com COMMERCIAL COMBUSTION AIR IN-FORCER PAI-3 TM MODELS PAI-5 PAI-7 PAI-4 PAI-6 OWNER INSTRUCTIONS, DO NOT DESTROY !Recognize this symbol as an indication of important Safety Information! THESE INSTRUCTIONS ARE INTENDED AS AN AID TO QUALIFIED, LICENSED SERVICE PERSONNEL FOR PROPER INSTALLATION, ADJUSTMENT AND OPERATION OF THIS UNIT. READ THESE INSTRUCTIONS THOROUGHLY BEFORE ATTEMPTING INSTALLATION OR OPERATION. FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN IMPROPER INSTALLATION, ADJUSTMENT, SERVICE OR MAINTENANCE POSSIBLY RESULTING IN FIRE, ELECTRICAL SHOCK, CARBON MONOXIDE POISONING, EXPLOSION, OR PERSONAL INJURY OR PROPERTY DAMAGE. [. . . ] DIAGRAM B DIAGRAM C DIAGRAM D DIAGRAM E 6 IN-FORCER MOUNTING INSTALLER NOTE 1. For easier wiring and servicing maintain 18" clearance from the rear and control sides and 12" from the top of the IN-FORCER. For easier electrical interlock plan for sufficient duct so that the IN-FORCER can be suspended adjacent to the heating equipment that it serves. Do not directly discharge onto water piping or objects that may be affected by temperature extremes. In areas with low temperature extremes it is advisable to insulate ducts or use insulated duct. Do not exceed equivalent duct lengths listed in IN-FORCER Selection Table on Page 3. MODELS PAI-3 & PAI-4 (DIAGRAM F) Verify that overhead support has sufficient strength to hold weight of IN-FORCER. Bend mounting support flanges to the angle best suited to the specific installation. Use perforated strap (installer supplied) and the provided 1/4"-20 x 3/4" hex head bolts and kep nuts to secure strap to the holes in the mounting flanges, (See Diagram F). MODELS PAI-5, PAI-6, PAI-7 (DIAGRAM G) Verify that overhead support has sufficient strength to hold weight of IN-FORCER. The eyebolts may be secured to either the top or bottom of the IN-FORCER casing. Attaching the eyebolts to the bottom allows the IN-FORCER inlet to be positioned to the opposite side, giving the option of a right hand or left-hand inlet pipe connection. On bottom of cabinet install 1/4"-20 x 3/4" hex head bolts, washers and nuts, (See Diagram G). DIAGRAM F DIAGRAM G 2. Connect crimped end of intake duct to the IN-FORCER inlet collar with sheet metal screws. Tape connection to inlet collar and all joints of intake duct to prevent the entry of indoor air. DIAGRAM H 3. The discharge should terminate no closer than 3 feet from a barometric draft control or intake grille of an appliance. If this is not possible terminate on sides or opposite side of appliance intake. Never terminate within 3 feet from the front or intake side of appliance. Discharge duct should also terminate a minimum of 18 inches above floor or other obstructions if perpendicular to them, (See Diag. These clearances are necessary to prevent pilot outages and ensure proper draft control operation. 7 ELECTRICAL All wiring from the IN-FORCER to the appliance must be appropriate Class 1 wiring as follows: installed in rigid metal conduit, intermediate conduit, rigid non-metallic conduit, electrical metallic tubing, Type MI Cable, Type MC Cable or be otherwise suitably protected from physical damage. The IN-FORCER has a high temperature limit switch to deactivate the system in the event of a mechanical room fire. It also has a fan proving switch to prove operation prior to burner ignition. IN-FORCER INTERNAL WIRING SCHEMATIC IN-FORCER WIRED WITH FAN PROVER AND MOTOR ISOLATION RELAYS ACCESSORY RELAYS FOR ISOLATION 24/115 Volt 1/2 H. P. [. . . ] Date of original installation and dates any service work was performed. LIMITED PARTS WARRANTY AND CLAIM PROCEDURE When contacting Tjernlund Products, Inc. , please have the following information available: Tjernlund Products, Inc. warrants the components of its products for one year from date of installation. This warranty does not cover normal maintenance, transportation or installation charges for replacement parts or any other service calls or repairs. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TJERNLUND PAI-3,4,5,6,7 COMMERCIAL COMBUSTION AIR IN-FORCER 8504036 REV A 0501




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual TJERNLUND PAI-3,4,5,6,7 COMMERCIAL COMBUSTION AIR IN-FORCER 8504036 REV A 0501 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.