User manual TJERNLUND PAI-1 & 2T FRESH AIR IN-FORCER 8504039 REV A 0600
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual TJERNLUND PAI-1 & 2T FRESH AIR IN-FORCER 8504039 REV A 0600. We hope that this TJERNLUND PAI-1 & 2T FRESH AIR IN-FORCER 8504039 REV A 0600 user guide will be useful to you.
Manual abstract: user guide TJERNLUND PAI-1 & 2T FRESH AIR IN-FORCER 8504039 REV A 0600
Detailed instructions for use are in the User's Guide.
[. . . ] A 6/00
TJERNLUND PRODUCTS, INC.
1601 Ninth Street · White Bear Lake, MN 55110-6794 PHONE (800) 255-4208 · (651) 426-2993 · FAX (651) 426-9547 Visit our web site · www. tjernlund. com
IN-FORCER MODELS PAI-1T & PAI-2T
TM
INSTALLATION INSTRUCTIONS
OWNER'S INSTRUCTIONS, DO NOT DESTROY
THIS DEVICE MUST BE INSTALLED BY A QUALIFIED PERSON. READ INSTRUCTIONS CAREFULLY PRIOR TO INSTALLATION AND OPERATION OF THE AIR INTAKE SYSTEM.
Copyright © 2000, Tjernlund Products, Inc. All rights reserved.
P/N 8504039
TABLE OF CONTENTS Descriptions and Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Installation Restrictions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Cautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Timer/Clock Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Recommended Patterns of Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3 IN-FORCER Terminology . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Recommended Mounting and Discharge Termination Locations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Determining IN-FORCER CFM Capabilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-5 Installation Tools Required . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Cutting PVC Opening through Wall . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 IN-FORCER Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Installation of Pipe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-7 Installation of Intake Elbow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-8 Electrical Ladder Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Trouble Shooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 How to Obtain Service & Warranty. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-11 Replacement Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Installer Comments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12-13 PVC Hole Template . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 IN-FORCERTM is a trademark of Tjernlund Products, Inc. DESCRIPTION The IN-FORCER model PAI-1T is a Listed mechanical intake fan which provides fresh outdoor air for indoor ventilation purposes. [. . . ] IN ADDITION TO THESE CODES THE MANUFACTURER RECOMMENDS THAT: · The intake elbow should be a minimum of 1 foot above grade or anticipated snow line. Using 1/2" bit, drill pilot holes noted on the template from inside through rim joist, wall board, siding, etc. , keeping drill bit perpendicular to the wall. Remove template from rim joist and attach to building exterior, aligning pilot hole markings on template with holes previously created in Step #2. Using 3-1/2" hole saw or a reciprocating saw and appropriate blade, cut opening through rim joist, wall board, siding, etc. , following the template outline for the pipe, (See Diagram D). DIAGRAM D
TRUSS MOUNTING If IN-FORCER will be mounted on a floor truss instead of a joist follow this section, otherwise, skip to installation of IN-FORCER. Secure plywood to trusses with a minimum of 4-8 penny nails or 1-1/2" wood screws.
5
INSTALLATION OF IN-FORCER A minimum two foot length of PVC intake pipe is recommended so the IN-FORCER can be easily serviced. If intake PVC pipe lengths are relatively short, the pipe can be cemented to the IN-FORCER coupler and fed through exterior opening before securing to the wall. If PVC pipe run is extended, first secure IN-FORCER to joist/truss, then extend PVC pipe run through exterior opening and cement to PVC coupler. Note: Before cutting opening through wall, consider layout of PVC pipe runs and confirm intake elbow termination clearances are met as shown on page 4.
1. Assemble vibration mount brackets on IN-FORCER as shown below in diagram E. Install IN-FORCER 1/2" below subfloor making sure that unit is level. NOTE: 1/2" space must be followed so PVC pipe lines up with hole template. Level IN-FORCER on underside length wise and width wise making sure it is level in both planes, (See Diagram F). Once determined IN-FORCER is level, secure to wall with provided screws, (See Diagram G). Note: Drill 4 - 1/4" holes and use wall anchors provided if installing on masonry wall. DIAGRAM F DIAGRAM G
INSTALLATION OF PIPE Schedule 40 or schedule 80 3" PVC pipe is recommended on the intake side of the IN-FORCER. Standard 6" metal vent or flex duct is acceptable for discharge vent runs. If using flex duct, make sure adherence to manufacturers restrictions is followed. Each 90 degree 3" PVC elbow is equal to 5 feet of straight pipe, each 45 degree elbow is equal to 2-1/2 feet of straight pipe. Each 90 degree elbow of 6" metal vent pipe is equal to 10 feet of straight pipe, each 45 degree elbow is equal to 5 feet of straight pipe. EQUIVALENT PIPE LENGTH CALCULATION EXAMPLE DIAGRAM H
* Intake elbow & gooseneck do not need to be included for equivalent length calculation. These exterior PVC pipe fittings have already been accounted for in CFM calculations, (See Table 2 or 3).
6
Plan vent runs with desired CFM requirements in mind. [. . . ] Model number and date code of the IN-FORCER Name and address of installer and service agency Date of original installation and dates any service work was performed Details of the problem LIMITED PARTS WARRANTY AND CLAIM PROCEDURE Tjernlund Products, Inc. warrants the components of the IN-FORCER for one year from date of installation. This warranty does not cover normal maintenance, transportation or installation charges for replacement parts or any other service calls or repairs. This warranty DOES NOT cover the complete IN-FORCER if it is operative, except for the defective part. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE TJERNLUND PAI-1 & 2T FRESH AIR IN-FORCER 8504039 REV A 0600
Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual TJERNLUND PAI-1 & 2T FRESH AIR IN-FORCER 8504039 REV A 0600 will begin.