If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual TJERNLUND HSJ, 1, 2 WITH UC1 UNIVERSAL CONTROL (VERSION X.06) 8504106 REV C 0705. We hope that this TJERNLUND HSJ, 1, 2 WITH UC1 UNIVERSAL CONTROL (VERSION X.06) 8504106 REV C 0705 user guide will be useful to you.
Manual abstract: user guide TJERNLUND HSJ, 1, 2 WITH UC1 UNIVERSAL CONTROL (VERSION X.06) 8504106 REV C 0705
Detailed instructions for use are in the User's Guide.
[. . . ] TJERNLUND PRODUCTS, INC.
1601 Ninth Street · White Bear Lake, MN 55110-6794 PHONE (800) 255-4208 · (651) 426-2993 · FAX (651) 426-9547 Visit our web site · www. tjernlund. com
IMPORTANT!!!UC1 BOARD VERSION X. 06 UPDATES
NEW X. 06 VERSION UC1 BOARD FEATURES
IMPORTANT: This upgraded circuit board features: A new #6 power LED Constant red when 115 VAC is supplied to L & N. A new color for the #2 LED Constant blue when fan prover safety circuit is closed. A revised #5 LED With no call for heat present, flashes 3 seconds on / 3 seconds off if microcontroller is working properly.
New LED # 6 RED 115V power supplied to UC1 L & N terminals
P1 P2 C GND F
LED 6 (RED) POWER LED (1 9)
LED # 2 now BLUE (previously GREEN) LED # 5 RED With no call for heat, flashes 3 seconds on / 3 seconds off if microcontroller is working properly.
LED 1 (AMBER) LED 2 (BLUE) LED 3 (GREEN) LED 4 (RED) LED 5 (RED) DRY 24 V 115 V J1 J2 XL XN N M MTR APPLIANCE INTERLOCK RELAY VENTER MOTOR RELAY
AB 1 2 3 4 LN
IMPORTANT: For 950-8804 UC1 Replacement Board Kits: If this is a 950-8804 UC1 board kit and you are replacing an existing UC1 board with this new board, note Dip Switch settings on existing UC1 circuit board so that those same settings can be positioned on this replacement circuit board. [. . . ] Review all of the wiring diagram options prior to choosing the best method. SEQUENCE OF OPERATION WITH UC1 UNIVERSAL CONTROL AND 24 VAC OR 115 VAC HEATER CONTROL CIRCUIT: Control signal from thermostat, aquastat, primary control or gas valve is intercepted and routed to terminal "1" on UC1 terminal strip. When terminal "1" is energized with either 24 VAC or 115 VAC, the Venter motor is energized. After draft is established, the Fan Proving Switch closes within 5 to 10 seconds energizing terminal "4", which completes the circuit allowing burner to fire. NOTE: If a Venter pre-purge is selected, the burner will not fire until the pre-purge time is finished. The Venter will continue to run after the burner has finished firing for the set post-purge time cycle. The UC1 is set for a 2 minute post-purge time period from the factory. The "1" input terminal on the UC1 can accept either a 24 VAC or 115 VAC control signal. IMPORTANT: The RED voltage jumper must be positioned based on appliance interlock voltage 24V or 115V. If using the "DRY" contact activation method, use terminals A & B on UC1 control and position the RED voltage jumper tab in the "DRY" position. Multiple appliance interlocks require the use of our MAC-Series multiple appliance controls. The steps listed under each diagram are intended as a supplement to the diagram. If you are unable to wire the UC1 as outlined in these instructions, call Tjernlund's Customer Service Department toll free at 1-800-255-4208 for assistance. IMPORTANT: If the call for heat interlock signal or 115 VAC power is removed, the UC1 board will reset and any fault, if present, will be stored in memory instead of displayed. See page 5, "Checking Memory for Last Fault Code".
10
UC1 UNIVERSAL CONTROL WIRING SCHEMATIC The Ground lead, Venter motor and Fan Prover leads are factory connected to the UC1 circuit board. Venter Ground, motor and Fan Prover wiring connections are made at the free end of the 2 foot whip in HS-Series junction box.
LEGEND: 115 VAC 5 VDC BOARD-GENERATED POWER DO NOT SUPPLY POWER!24 OR 115 VAC TERMINAL 1: 24 OR 115 VAC INTERCEPTED CALL FOR HEAT TERMINAL 2: INTERCEPTED CALL COMMON OR NEUTRAL TERMINAL 4: APPROVED CALL BACK TO HEATER
DO NOT SUPPLY VOLTAGE TO "A" OR "B". USER-PROVIDED CALL SWITCH "DRY" INTERCEPTED CALL FOR HEAT OR LINE / HOT COMMON / NEUTRAL J2 J1 XL
NO
IMPORTANT: RED JUMPER POSITION MUST BE THE SAME AS APPLIANCE INTERLOCK VOLTAGE.
LED5 LED4 LED3 LED2 LED1 LED6
115V
DRY
CALL JUMPER
COM
24V
RED POWER LED
APPROVED CALL SUPPLY 115 VAC 50/60 Hz
R
INTERLOCK RELAY K1
RED
RED
BLUE
XN K2 N
OPEN PROVER OPTION (9)
GREEN
PRE-PURGE SETTINGS (1 - 2) POST-PURGE SETTINGS (3 - 8)
AMBER
P2 P1 PROVER C GND F FOR TJERNLUND MAC1E OR MAC4E AUXILIARY DEVICES. DOING SO WILL DAMAGE THE CONTROL.
ON 123456789
9183006 TJERNLUND PRODUCTS, INC.
VENTER MOTOR
1 H. P. MAX @ 115 VAC
COM
WARNING: Disconnect power supply from the UC1 and heating equipment when making wiring connections and servicing the Venter. Failure to do so may result in personal injury and/or equipment damage. WIRING CONNECTIONS FROM UC1 UNIVERSAL CONTROL MADE IN HS-SERIES JUNCTION BOX 1. [. . . ] Name and address of installer and any service agency who performed work on Venter. Date of original installation and dates any service work was performed. Details of the problem as you can best describe them.
LIMITED PARTS WARRANTY AND CLAIM PROCEDURE
Tjernlund Products, Inc. warrants the components of the Venter and UC1 for 1 year from date of installation. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE TJERNLUND HSJ, 1, 2 WITH UC1 UNIVERSAL CONTROL (VERSION X.06) 8504106 REV C 0705
Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual TJERNLUND HSJ, 1, 2 WITH UC1 UNIVERSAL CONTROL (VERSION X.06) 8504106 REV C 0705 will begin.