User manual TJERNLUND HSJ, 1, 2 WITH UC1 UNIVERSAL CONTROL (VERSION X.04) 8504106 REV B 0503
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual TJERNLUND HSJ, 1, 2 WITH UC1 UNIVERSAL CONTROL (VERSION X.04) 8504106 REV B 0503. We hope that this TJERNLUND HSJ, 1, 2 WITH UC1 UNIVERSAL CONTROL (VERSION X.04) 8504106 REV B 0503 user guide will be useful to you.
Manual abstract: user guide TJERNLUND HSJ, 1, 2 WITH UC1 UNIVERSAL CONTROL (VERSION X.04) 8504106 REV B 0503
Detailed instructions for use are in the User's Guide.
[. . . ] B 05/03
TJERNLUND PRODUCTS, INC.
1601 Ninth Street · White Bear Lake, MN 55110-6794 PHONE (800) 255-4208 · (651) 426-2993 · FAX (651) 426-9547 Visit our web site · www. tjernlund. com
VERSION X. 04
FOR NATURAL GAS, LP OR OIL
INCLUDES NEW UC1 UNIVERSAL CONTROL
MODELS HSJ HS1 HS2
OWNER INSTRUCTIONS, DO NOT DESTROY
!Recognize this symbol as an indication of important Safety Information!
NOTE:
FLUE GAS TEMPERATURES MUST NOT EXCEED 600OF AT VENT SYSTEM INLET FOR U. S. INSTALLATIONS AND 285OC (550OF) AT VENT SYSTEM INLET FOR CANADIAN INSTALLATIONS.
THESE INSTRUCTIONS ARE INTENDED AS AN AID TO QUALIFIED, LICENSED SERVICE PERSONNEL FOR PROPER INSTALLATION, ADJUSTMENT AND OPERATION OF THIS UNIT. READ THESE INSTRUCTIONS THOROUGHLY BEFORE ATTEMPTING INSTALLATION OR OPERATION. [. . . ] Venter Ground, motor and Fan Prover wiring connections are made at the free end of the 2 foot whip in HS-Series junction box.
LEGEND: 115 VAC 24 VAC 5 VDC BOARD-GENERATED POWER DO NOT SUPPLY POWER!115 OR 24 VAC FROM CALL JUMPER OR USER-PROVIDED VOLTAGE FROM TERMINAL 3 TO 4 WITH CALL JUMPER REMOVED
DO NOT SUPPLY VOLTAGE TO "A" OR "B". USER-PROVIDED CALL SWITCH "DRY" OR LINE HOT 115 VAC OR 24 VAC NEUTRAL COMMON APPROVED SUPPLY 115 VAC 50/60 Hz
R
IMPORTANT: RED JUMPER POSITION MUST BE THE SAME AS APPLIANCE INTERLOCK VOLTAGE.
LED5 LED4 LED3 LED2 LED1
115V J2 J1 XL XN N
DRY K2
CALL JUMPER
COM
NO
24V
INTERLOCK RELAY K1
RED
RED
OPEN PROVER OPTION (9)
GREEN
PRE-PURGE SETTINGS (1 - 2) POST-PURGE SETTINGS (3 - 8)
GREEN
AMBER
ON 123456789
P2 P1 PROVER C GND F FOR TJERNLUND MAC1E OR MAC4E AUXILIARY DEVICES. DOING SO WILL DAMAGE THE CONTROL.
9183006 TJERNLUND PRODUCTS, INC.
MOTOR
1 H. P. MAX @ 115 VAC
COM
WARNING: Disconnect power supply from the UC1 and heating equipment when making wiring connections and servicing the Venter. Failure to do so may result in personal injury and/or equipment damage. WIRING CONNECTIONS FROM UC1 UNIVERSAL CONTROL MADE IN HS-SERIES JUNCTION BOX 1. Connect Black and White leads from UC1 whip to Venter motor leads.
HSJ, 1, 2 ELECTRICAL BOX
M MTR
NO
MOTOR RELAY
D/N 1303958-1
2 FT. Connect Blue and Yellow leads from UC1 whip to Fan Prover switch terminals in Venter. Yellow lead should be on switch terminal closest to Venter junction box wall.
FAN PROVER
GRE EN
BL UE YE LL OW
BL AC K
W
HI
4. Insert provided hole plug in HS-Series junction box in opening opposite UC1 whip. MULTIPLE APPLIANCE INTERLOCKS To interlock with one additional 24/115 VAC heater add the MAC1E. It is a stripped down auxiliary board version of the UC1 and is powered by and communicates with the UC1 through a factory wired whip. To interlock more than two 24/115 VAC heaters, add the MAC4E for a total of up to 5 heaters. It is powered by and communicates with the UC1 through a factory wired whip. To interlock a millivolt water heater and a 24/115 VAC furnace or boiler, add the WHKE and MAC1E. MILLIVOLT INSTALLATIONS Each millivolt appliance interlocked with the UC1 must have its own WHKE kit installed. The WHKE Gas Pressure Switch actuates the Venter through the A - B Dry contacts. The Linear Limit switch disables the heater in the event of a venting malfunction. IMPORTANT: Each millivolt appliance interlocked with the UC1 must have its own Linear Limit spill switch. MULTIPLE MILLIVOLT HEATER INSTALLATIONS Multiple millivolt heaters can be installed by using the A-B dry contact terminals of the UC1, MAC1E or MAC4E. Wire each WHKE gas pressure switch in parallel across A-B terminals of UC1, MAC1E or MAC4E. [. . . ] Name and address of installer and any service agency who performed work on Venter. Date of original installation and dates any service work was performed. Details of the problem as you can best describe them.
LIMITED PARTS WARRANTY AND CLAIM PROCEDURE
Tjernlund Products, Inc. warrants the components of the Venter and UC1 for 1 year from date of installation. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE TJERNLUND HSJ, 1, 2 WITH UC1 UNIVERSAL CONTROL (VERSION X.04) 8504106 REV B 0503
Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual TJERNLUND HSJ, 1, 2 WITH UC1 UNIVERSAL CONTROL (VERSION X.04) 8504106 REV B 0503 will begin.