User manual TJERNLUND HS3,4,5 WITH UC1 UNIVERSAL CONTROL (VERSION X.02) 8504111 REV 0902

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual TJERNLUND HS3,4,5 WITH UC1 UNIVERSAL CONTROL (VERSION X.02) 8504111 REV 0902. We hope that this TJERNLUND HS3,4,5 WITH UC1 UNIVERSAL CONTROL (VERSION X.02) 8504111 REV 0902 user guide will be useful to you.


TJERNLUND HS3,4,5 WITH UC1 UNIVERSAL CONTROL (VERSION X.02) 8504111 REV 0902 : Download the complete user guide (675 Ko)

Manual abstract: user guide TJERNLUND HS3,4,5 WITH UC1 UNIVERSAL CONTROL (VERSION X.02) 8504111 REV 0902

Detailed instructions for use are in the User's Guide.

[. . . ] 9/02 TJERNLUND PRODUCTS, INC. 1601 Ninth Street · White Bear Lake, MN 55110-6794 PHONE (800) 255-4208 · (651) 426-2993 · FAX (651) 426-9547 Visit our web site · www. tjernlund. com MODELS HS3 HS4 HS5 FOR NATURAL GAS OR LP INCLUDES NEW UC1 UNIVERSAL CONTROL FAN PROVER VENTER UC1 OWNER INSTRUCTIONS, DO NOT DESTROY !Recognize this symbol as an indication of important Safety Information! NOTE: FLUE GAS TEMPERATURES MUST NOT EXCEED 600oF AT VENT SYSTEM INLET. THESE INSTRUCTIONS ARE INTENDED AS AN AID TO QUALIFIED, LICENSED SERVICE PERSONNEL FOR PROPER INSTALLATION, ADJUSTMENT AND OPERATION OF THIS UNIT. READ THESE INSTRUCTIONS THOROUGHLY BEFORE ATTEMPTING INSTALLATION OR OPERATION. FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN IMPROPER INSTALLATION, ADJUSTMENT, SERVICE OR MAINTENANCE POSSIBLY RESULTING IN FIRE, ELECTRICAL SHOCK, CARBON MONOXIDE POISONING, EXPLOSION, PERSONAL INJURY OR PROPERTY DAMAGE. [. . . ] UC1 UNIVERSAL CONTROL WIRING SCHEMATIC The Ground lead, Venter motor and Fan Prover leads are factory connected to the UC1 circuit board. Venter Ground, motor and Fan Prover wiring connections are made at the free end of the 2 foot whip. As viewed from the opposite end of the shaft (rear of motor), the motor should rotate clockwise. See motor nameplate for proper rotation. LEGEND: 115 VAC 24 VAC 5 VDC BOARD-GENERATED POWER DO NOT SUPPLY POWER!115 OR 24 VAC FROM CALL JUMPER OR USER-PROVIDED VOLTAGE FROM TERMINAL 3 TO 4 WITH CALL JUMPER REMOVED DO NOT SUPPLY VOLTAGE TO "A" OR "B". USER-PROVIDED CALL SWITCH "DRY" OR LINE HOT 115 VAC OR 24 VAC NEUTRAL COMMON APPROVED SUPPLY 115 VAC 50/60 Hz R IMPORTANT: RED JUMPER POSITION MUST BE THE SAME AS APPLIANCE INTERLOCK VOLTAGE. 115V J2 J1 XL NO LED5 LED4 LED3 LED2 LED1 DRY CALL JUMPER COM 24V INTERLOCK RELAY K1 RED RED XN K2 N OPEN PROVER OPTION (9) GREEN PRE-PURGE SETTINGS (1 - 2) POST-PURGE SETTINGS (3 - 8) GREEN AMBER ON 123456789 P2 P1 PROVER C GND F FOR TJERNLUND MAC1E OR MAC4E AUXILIARY DEVICES. DOING SO WILL DAMAGE THE CONTROL. 9183006 TJERNLUND PRODUCTS, INC. MOTOR 1 H. P. MAX @ 115 VAC COM WARNING: Disconnect power supply from the UC1 and heating equipment when making wiring connections and servicing the Venter. Failure to do so may result in personal injury and/or equipment damage. WIIRING CONNECTIONS FROM UC1 TO FAN PROVER AND VENTER MOTOR MODELS HS4 & HS5 (ONLY) Connect Black and White motor ring terminal leads to ring terminal studs on motor. As viewed from the opposite end of the shaft (rear of motor), the motor should rotate clockwise. Connect ground wire from UC1 whip and Venter motor ground wire to ground screw in Fan Prover junction box. Connect Black and White motor leads from UC1 whip to Venter motor leads in Fan Prover junction box. Connect Blue and Yellow leads from UC1 whip to Fan Prover switch terminals. MULTIPLE APPLIANCE INTERLOCKS To interlock with one additional 24/115 VAC heater add the MAC1E. It is a stripped down auxiliary board version of the UC1 and is powered by and communicates with the UC1 through a factory wired whip. To interlock more than two 24/115 VAC heaters, add the MAC4E for a total of up to 5 heaters. It is powered by and communicates with the UC1 through a factory wired whip. To interlock a millivolt water heater and a 24/115 VAC furnace or boiler, add the WHKE and MAC1E. MILLIVOLT INSTALLATIONS Each millivolt appliance interlocked with the UC1 must have its own WHKE kit installed. The WHKE Gas Pressure Switch actuates the Venter through the A - B Dry contacts. [. . . ] Sensing tube assembly provided with factory calibrated length must be used or Fan Prover will not work properly. If the Venter requires adjustment or repair, we suggest that you contact your installer, contractor or service agency. Model of the Venter the UC1 is interlocked with as shown on the label attached to Venter. Name and address of installer and any service agency who performed work on Venter. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TJERNLUND HS3,4,5 WITH UC1 UNIVERSAL CONTROL (VERSION X.02) 8504111 REV 0902




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual TJERNLUND HS3,4,5 WITH UC1 UNIVERSAL CONTROL (VERSION X.02) 8504111 REV 0902 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.