User manual TJERNLUND HS-3,4,5 (DISCONTINUED VERSION-PRE UC1 UNIVERSAL CONTROL) 8504031 REV A 0999

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual TJERNLUND HS-3,4,5 (DISCONTINUED VERSION-PRE UC1 UNIVERSAL CONTROL) 8504031 REV A 0999. We hope that this TJERNLUND HS-3,4,5 (DISCONTINUED VERSION-PRE UC1 UNIVERSAL CONTROL) 8504031 REV A 0999 user guide will be useful to you.


TJERNLUND HS-3,4,5 (DISCONTINUED VERSION-PRE UC1 UNIVERSAL CONTROL) 8504031 REV A 0999 : Download the complete user guide (469 Ko)

Manual abstract: user guide TJERNLUND HS-3,4,5 (DISCONTINUED VERSION-PRE UC1 UNIVERSAL CONTROL) 8504031 REV A 0999

Detailed instructions for use are in the User's Guide.

[. . . ] A 9/99 TJERNLUND PRODUCTS, INC. 1601 Ninth Street · White Bear Lake, MN 55110-6794 PHONE (800) 255-4208 · (651) 426-2993 · FAX (651) 426-9547 Visit our web site · www. tjernlund. com MODELS HS-3 HS-4 HS-5 FOR NATURAL GAS OR LP OWNER INSTRUCTIONS, DO NOT DESTROY !Recognize this symbol as an indication of important Safety Information! NOTE: FLUE GAS TEMPERATURES MUST NOT EXCEED 600 oF AT VENT SYSTEM INLET. THESE INSTRUCTIONS ARE INTENDED AS AN AID TO QUALIFIED, LICENSED SERVICE PERSONNEL FOR PROPER INSTALLATION, ADJUSTMENT AND OPERATION OF THIS UNIT. READ THESE INSTRUCTIONS THOROUGHLY BEFORE ATTEMPTING INSTALLATION OR OPERATION. FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN IMPROPER INSTALLATION, ADJUSTMENT, SERVICE OR MAINTENANCE POSSIBLY RESULTING IN FIRE, ELECTRICAL SHOCK, CARBON MONOXIDE POISONING, EXPLOSION, PERSONAL INJURY OR PROPERTY DAMAGE. [. . . ] If possible, locate the Vent Hood no closer than 3 feet from an inside corner of an L-shaped structure. CODE REQUIREMENTS Terminate the vent system so that proper minimum clearances are maintained as cited in the latest edition of the National Fuel Gas Code (NFPA # 54) and the latest edition of Chimneys, Fireplaces, Vents, and Solid Fuel Burning Appliances, (NFPA #211), or as follows: · · · · · · Not be less than 7 feet above grade when located adjacent to public walk ways. At least 4 feet below, 4 feet horizontally from or 1 foot above any door, window or gravity air inlet into any building. So that the flue gases are not directed so as to jeopardize people, overheat combustible structures or enter buildings, and Not less than 2 feet from an adjacent building. 3 POWER VENTER MOUNTING The installer must supply plumber's strap or 1/4" threaded rod with nuts and washers for mounting. The Power Venter may be mounted in any position as long as the shaft of the motor remains horizontal. The Power Venter housing is single wall, 6 inches must be maintained from all combustible materials. It is recommended that the Power Venter be mounted as close as possible to the point of termination. HS-3 HS-4, HS-5 VENT PIPE INSTALLATION If Installing the Power Venter on an appliance not equipped with a draft hood or draft diverter (e. g. Power Burners, Induced Draft), a barometric draft control must be added. The barometric draft control must be the same size as the flue outlet and installed as close as possible to the appliance. After the draft hood, draft diverter or barometric draft control, a tapered reducer should be installed to reduce the flue to the size shown in the selection table on page 2 of these instructions. After the tapered reducer, install the appropriate type of vent pipe to the inlet of the Power Venter. The Power Venter inlet and outlet are designed to accept single wall vent pipe. If using vent pipe other than single wall, the installer must supply adapters to connect to the Power Venter. While it is recommended that the Power Venter be mounted at the point of termination, it is acceptable to install vent pipe between the outlet of the Power Venter and the point of termination. The Installer must seal all vent pipe connections after the Power Venter with high-temperature caulk or aluminum vent pipe tape to prevent flue gas leakage during operation. The size of the vent pipe between the Power Venter and point of termination should be the same size shown on the selection table. IMPORTANT: Elbows placed directly after discharge on Power Venter may cause erratic operation of Fan Prover. If elbows are necessary on discharge, allow for a straight section of pipe 3 times the vent diameter being used before installing an elbow. 4 FAN PROVING SWITCH INSTALLATION NOTE: It is important that the electrical box is mounted with the Fan Proving Switch in a vertical position. Mount supplied electrical box to a flat surface within 2 feet of the Power Venter with Proving Switch in a vertical position. Connect the 1/4" aluminum tubing from the Fan Proving Switch to the Power Venter housing using supplied fittings. The factory calibrated sensing tube length and compression fittings are critical for proper operation of the Fan Proving Switch. HS-3, HS-4, HS-5 CONNECTED TO APPLIANCE WITH SPARK IGNITION WARNING: The BLACK & WHITE motor wires shown in this diagram are applicable only for the HS-3. [. . . ] Model number of the Power Venter Name and address of installer and service agency Date of original installation and dates any service work was performed Details of the problem 10 LIMITED PARTS WARRANTY AND CLAIM PROCEDURE Tjernlund Products, Inc. warrants the components of its products for one year from date of installation. This warranty does not cover normal maintenance, transportation or installation charges for replacement parts or any other service calls or repairs. Products that are tampered with, damaged, or defective due to malfunctioning appliances are not covered under this warranty. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TJERNLUND HS-3,4,5 (DISCONTINUED VERSION-PRE UC1 UNIVERSAL CONTROL) 8504031 REV A 0999




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual TJERNLUND HS-3,4,5 (DISCONTINUED VERSION-PRE UC1 UNIVERSAL CONTROL) 8504031 REV A 0999 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.