User manual TJERNLUND GPAK GAS SIDE WALL VENT SYSTEMS (GPAK-J,1,JT,1T DISCONTINUED) 8500370 REV. 4 0198

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual TJERNLUND GPAK GAS SIDE WALL VENT SYSTEMS (GPAK-J,1,JT,1T DISCONTINUED) 8500370 REV. 4 0198. We hope that this TJERNLUND GPAK GAS SIDE WALL VENT SYSTEMS (GPAK-J,1,JT,1T DISCONTINUED) 8500370 REV. 4 0198 user guide will be useful to you.


TJERNLUND GPAK GAS SIDE WALL VENT SYSTEMS (GPAK-J,1,JT,1T DISCONTINUED) 8500370 REV. 4 0198 : Download the complete user guide (637 Ko)

Manual abstract: user guide TJERNLUND GPAK GAS SIDE WALL VENT SYSTEMS (GPAK-J,1,JT,1T DISCONTINUED) 8500370 REV. 4 0198

Detailed instructions for use are in the User's Guide.

[. . . ] Packaged Side Wall Vent Systems Ideal For Replacing Plastic Pipe On 80-Plus Gas Furnaces Safety and performance features time-proven in over one million installations: s All operating components located indoors for weather protection and easy servicing. [. . . ] Interlock Relay or Timer/Relay and Fan Proving Switch with burner. GPAK-JT, 1T Timer/Relay -- 24/115V Switching Relay, 45 Second Fixed Delay Fan Proving Switch -- 3FLA, 18 LRA@120 VAC MODEL SELECTION TABLE NOTES: 1. If the appliance flue outlet is greater than 4'', install a tapered reducer after the draft hood, draft diverter or barometric draft control, reducing vent pipe diameter to 4''. All vent pipe from the appliance to the Power Venter may be 4''. Maximum Total Vent Pipe Length Models Vent Pipe Diameter BTU/hr Input *40, 000 ATM Atmospheric Fan Assisted +Column B A B C GPAK-J GPAK-JT *GPAK-JT* 4'' 45, 000 75, 000 100, 000 120, 000 100' 100' 100' 45' 60' 60' 60' 60' 60' 60' N/A N/A 60' 60' 60' N/A N/A 100' 60' 100, 000 3. Determine maximum pipe length from GPAK-1 type of equipment being vented and 100' 60' 120, 000 GPAK-1T 4'' GPAK Model. Column A pipe runs 100' 60' 150, 000 *GPAK-1T* over 30 linear feet should use Type 87' N/A 200, 000 "B" vent. Column B & C pipe runs over 15 linear feet should use Type 40' N/A 250, 000 "B" vent. input atmospheric water heater common vented with a fan assisted appliance from column B. 5. [. . . ] Also available, *GPAK-1TR* for use with Rheem, Ruud, Weatherking and Heat Controller brands. DISTRIBUTED BY: ® TJERNLUND PRODUCTS, INC. 1601 Ninth Street White Bear Lake, MN 55110-6794 Phone: 612. 426. 2993 800. 255. 4208 Fax: 612. 426. 9547 Copyright © 1997 Tjernlund Products Inc. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TJERNLUND GPAK GAS SIDE WALL VENT SYSTEMS (GPAK-J,1,JT,1T DISCONTINUED) 8500370 REV. 4 0198




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual TJERNLUND GPAK GAS SIDE WALL VENT SYSTEMS (GPAK-J,1,JT,1T DISCONTINUED) 8500370 REV. 4 0198 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.