User manual TJERNLUND DUCT BOOSTER IN-LINE DUCT FANS 8500380 REV. A 0104
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual TJERNLUND DUCT BOOSTER IN-LINE DUCT FANS 8500380 REV. A 0104. We hope that this TJERNLUND DUCT BOOSTER IN-LINE DUCT FANS 8500380 REV. A 0104 user guide will be useful to you.
Manual abstract: user guide TJERNLUND DUCT BOOSTER IN-LINE DUCT FANS 8500380 REV. A 0104
Detailed instructions for use are in the User's Guide.
[. . . ] Residential
Commercial
Du
by
®
Tjernlund
Whether you need to boost air flow for heating or cooling, or pulling power to exhaust air, Tjernlund has the right Duct Booster Fan for the job. All Tjernlund supply and exhaust Duct Booster Fans are engineered for easy installation, quiet operation and years of trouble-free service. [. . . ] Max Max Amps Watts Volts RPM . 17 19 115 2950 . 74 84 115 2700 1. 02 116 115 2600 0" 117 257 481 CFM vs Static Pressure 1/8" 1/4" 3/8" 1/2" 3/4" 1" 101 86 72 58 241 221 197 178 143 99 444 403 361 319 237 177 1 1/2" 76 Duct Dia. 4" 6" 8" Weight 6 Lbs 9 Lbs 11 Lbs
P-Series (Plastic Housing)
The ultimate bath/spa exhausters to eliminate fogged mirrors and lingering odors. They are also ideal for exhausting high moisture areas such as subslab radon gas mitigation and dryer vent boosting. Noryl housing · Horizontal or vertical mounting · Connects to rigid or flex ducts · Mounting bracket included
Dimensions:
Model P-4 P-6 P-8 OD 9 1/2 11 3/4 13 1/4 a 5 1/4 5 7/8 6 1/4 b 7/8 1 1 1/2 c 7/8 7/8 1 1/2 d 4 6 8 d1 5 6 1/4 10
Dimensions in inches
P-Series Electrical and Performance Data:
Model P-4 P-6 P-8 Nom. Max Max Amps Watts Volts RPM 80 115 2900 . 72 90 115 2700 . 77 115 2750 1. 10 122 0" 167 243 408 CFM vs Static Pressure 1/8" 1/4" 3/8" 1/2" 3/4" 1" 156 144 136 123 93 63 229 214 199 183 149 114 378 347 315 284 225 173 1 1/2" 4 18 72 Duct Dia. 4" 6" 8" Weight 5 Lbs 7 Lbs 9 Lbs
www. tjernlund. com
·
800. 255. 4208
Duct Booster® Fan Accessories
Duct Airstat Model PS1503
The Tjernlund Duct Airstat is used to automatically activate Duct Booster fans by sensing positive pressure in a forced air heating and/or cooling system. The single pole, single throw, snap-acting switch is activated by a diaphragm with a factory installed sampling probe inserted directly into the duct or plenum.
DR-10 Dryer Vent Switch
Used to automatically activate P-Series Duct Booster when dryer is in operation. DR-10 is a positive pressure sensing switch that recognizes dryer operation and activates the booster fan from an independent electrical circuit. Eliminates connections through the dryer circuit as well as manual systems which require attention of the operator. (Diaphragm Vertical)
SC-1 Speed Control
Typical Applications
Duct Airstat Duct Booster Electronic Air Cleaner Electronic Duct Heater Humidifier
115-120V
Speed Control turns Duct Fans on and off and can vary motor RPM. [. . . ] (4", 6" & 8" sizes. )
Duct Booster® Fan Selection Table
Bath/Spa Exhaust Duct Boosting Radon Mitigation Dryer Venting Breakroom or Kitchen Exhaust Office or Indoor/Outdoor Conference Rm Air Exhaust/Boost Supply/Exhaust
M-Series P-Series EA & EF-Series DB-2
·
· · · ·
· · · ·
· ·
· · · ·
Tjernlund Products also offers:
· Combustion and fresh air In-ForcersTM ensure adequate combustion air for heating equipment or to improve air quality problems. · Power Venters easily sidewall vent gas, LP and oil fired furnaces, water heaters and boilers.
Combustion & Fresh Air In-Forcers Sidewall Power Venters
Distributed by:
TJERNLUND PRODUCTS, INC.
1601 Ninth Street White Bear Lake, MN 55110-6794 Phone: 651. 426. 2993 800. 255. 4208 Fax: 651. 426. 9547 Visit our web site: www. tjernlund. com
Copyright © 2004 Tjernlund Products, Inc. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE TJERNLUND DUCT BOOSTER IN-LINE DUCT FANS 8500380 REV. A 0104
Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual TJERNLUND DUCT BOOSTER IN-LINE DUCT FANS 8500380 REV. A 0104 will begin.