User manual TJERNLUND 950-8804 UC1 UNIVERSAL CONTROL BOARD KIT (VERSION X.06) 8505017 REV D 0705

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual TJERNLUND 950-8804 UC1 UNIVERSAL CONTROL BOARD KIT (VERSION X.06) 8505017 REV D 0705. We hope that this TJERNLUND 950-8804 UC1 UNIVERSAL CONTROL BOARD KIT (VERSION X.06) 8505017 REV D 0705 user guide will be useful to you.


TJERNLUND 950-8804 UC1 UNIVERSAL CONTROL BOARD KIT (VERSION X.06) 8505017 REV D 0705 : Download the complete user guide (725 Ko)

Manual abstract: user guide TJERNLUND 950-8804 UC1 UNIVERSAL CONTROL BOARD KIT (VERSION X.06) 8505017 REV D 0705

Detailed instructions for use are in the User's Guide.

[. . . ] TJERNLUND PRODUCTS, INC. 1601 Ninth Street · White Bear Lake, MN 55110-6794 PHONE (800) 255-4208 · (651) 426-2993 · FAX (651) 426-9547 Visit our web site · www. tjernlund. com IMPORTANT!!!UC1 BOARD VERSION X. 06 UPDATES NEW X. 06 VERSION UC1 BOARD FEATURES IMPORTANT: This upgraded circuit board features: A new #6 power LED Constant red when 115 VAC is supplied to L & N. A new color for the #2 LED Constant blue when fan prover safety circuit is closed. A revised #5 LED With no call for heat present, flashes 3 seconds on / 3 seconds off if microcontroller is working properly. New LED # 6 RED 115V power supplied to UC1 L & N terminals P1 P2 C GND F LED 6 (RED) POWER LED (1 9) LED # 2 now BLUE (previously GREEN) LED # 5 RED With no call for heat, flashes 3 seconds on / 3 seconds off if microcontroller is working properly. LED 1 (AMBER) LED 2 (BLUE) LED 3 (GREEN) LED 4 (RED) LED 5 (RED) DRY 24 V 115 V J1 J2 XL XN N M MTR APPLIANCE INTERLOCK RELAY VENTER MOTOR RELAY AB 1 2 3 4 LN IMPORTANT: For 950-8804 UC1 Replacement Board Kits: If this is a 950-8804 UC1 board kit and you are replacing an existing UC1 board with this new board, note Dip Switch settings on existing UC1 circuit board so that those same settings can be positioned on this replacement circuit board. [. . . ] IMPORTANT: Each millivolt appliance interlocked with the UC1 must have its own Linear Limit spill switch. MULTIPLE MILLIVOLT HEATER INSTALLATIONS Multiple millivolt heaters can be installed by using the A-B dry contact terminals of the UC1, MAC1E or MAC4E. Wire each WHKE gas pressure switch in parallel across A-B terminals of UC1, MAC1E or MAC4E. Wire Linear Limit safety switch into each individual millivolt heater. UC1 BURNER INTERLOCK WIRING DIAGRAMS UC1 UNIVERSAL CONTROL CONNECTED WITH A 24 VAC ELECTRONIC IGNITION MODULE RED JUMPER POSITION MUST BE THE SAME AS APPLIANCE INTERLOCK VOLTAGE. SPARK (9) (8) J2 OR 115V UNIVERSAL CONTROLLER DRY CALL JUMPER 24V (7) 24V 24V GND BNR GND PV MV / PV MV (6) (5) (4) (3) (2) (1) PI YE J1 GR YE WH OR WH OR YE SUPPLY 115 VAC 50/60 Hz R XL XN PV PV MV MV GROUND HONEYWELL IGNITION CONTROL GR IMPORTANT: CRIMP GROUND WIRE TO GROUNDING SPADE TERMINAL IN ELECTRICAL BOX. LEGEND: 115 VAC 24 VAC GAS VALVE D/N 9183046-8 1. Remove the wire on MV at gas valve and connect it on #1 on UC1 terminal block. If not previously completed, connect ground from UC1 whip to Venter ground. 6 UC1 UNIVERSAL CONTROL CONNECTED WITH A SINGLE ZONE 24 VAC THERMOSTAT IMPORTANT: RED JUMPER POSITION MUST BE THE SAME AS APPLIANCE INTERLOCK VOLTAGE. THERMOSTAT Y R G R C J1 Y W INTERNAL CONTROL OF FURNACE SUPPLY 115 VAC 50/60 Hz R 115V DRY 24V W G J2 XL XN UNIVERSAL CONTROLLER CALL JUMPER LEGEND: 115 VAC 24 VAC D/N 9183046-5 GROUND IMPORTANT: CRIMP GROUND WIRE TO GROUNDING SPADE TERMINAL IN ELECTRICAL BOX. 1. Connect #2 on UC1 terminal block to C on internal control terminal strip of furnace/boiler. Connect #4 on UC1 terminal block to W on internal control terminal strip of furnace/boiler. If not previously completed, connect ground from UC1 whip to Venter ground. NOTE: If burner safety control goes out on lockout, the Venter will continue to run as long as a call for heat is present. UC1 UNIVERSAL CONTROL CONNECTED WITH A 24 OR 115 VAC STANDING PILOT IMPORTANT: RED JUMPER POSITION MUST BE THE SAME AS APPLIANCE INTERLOCK VOLTAGE. INTERNAL CONTROLS OF FURNACE/BOILER B2 COM Aquastat T-stat B1 HOT 115V J2 J1 DRY CALL JUMPER UNIVERSAL CONTROLLER 24V COM TR HOT TH SUPPLY 115 VAC 50/60 Hz GROUND IMPORTANT: CRIMP GROUND WIRE TO GROUNDING SPADE TERMINAL IN ELECTRICAL BOX. XL XN LEGEND: 115 VAC 24 OR 115 VAC D/N 9183046-1 24V OR 115V GAS VALVE 1. Remove the wire on TH or HOT of gas valve and connect it on #1 on UC1 terminal block. Make sure RED voltage jumper on UC1 is on 24V or 115V depending on control voltage. If not previously completed, connect ground from UC1 whip to Venter ground. 7 UC1 UNIVERSAL CONTROL AND WHKE INTERLOCK KIT CONNECTED WITH A MILLIVOLT APPLIANCE IMPORTANT: RED JUMPER POSITION MUST BE THE SAME AS APPLIANCE INTERLOCK VOLTAGE. GAS VALVE 115V DRY LEGEND: 115 VAC 5 VDC BOARDGENERATED POWER. DO NOT SUPPLY POWER! CALL JUMPER J2 WHKE GAS PRESSURE SWITCH SUPPLY 115 VAC 50/60 Hz R 24V UNIVERSAL CONTROLLER LINEAR LIMIT SPILL SWITCH J1 XL XN GROUND 950-0470 (JA1) THERMOCOUPLE JUNCTION ADAPTER MILLIVOLT D/N 9183046-9 IMPORTANT: CRIMP GROUND WIRE TO GROUNDING SPADE TERMINAL IN ELECTRICAL BOX. SAFETY CIRCUIT ACROSS P1 & P2 OF UC1 IS NOT UTILIZED IN THIS APPLICATION. SPILL SWITCH MUST BE INTERLOCKED WITH HEATING EQUIPMENT AS SHOWN. 30 MILLIVOLT WATER HEATERS REQUIRE USE OF THE 950-0470 THERMOCOUPLE JUNCTION ADAPTER. ON 750 MILLIVOLT (POWER PILE) WATER HEATERS WIRE LINEAR LIMIT SPILL SWITCH IN SERIES WITH HIGH LIMIT (ECO) OF WATER HEATER. [. . . ] Name and address of installer and any service agency who performed work on Venter. Date of original installation and dates any service work was performed. warrants the components of the UC1 for one year from date of installation. This warranty does not cover normal maintenance, transportation or installation charges for replacement parts or any other service calls or repairs. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TJERNLUND 950-8804 UC1 UNIVERSAL CONTROL BOARD KIT (VERSION X.06) 8505017 REV D 0705




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual TJERNLUND 950-8804 UC1 UNIVERSAL CONTROL BOARD KIT (VERSION X.06) 8505017 REV D 0705 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.