User manual TJERNLUND 950-2043 ND-1 POST PURGE BURNER KIT 8504004 REV 0196

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual TJERNLUND 950-2043 ND-1 POST PURGE BURNER KIT 8504004 REV 0196. We hope that this TJERNLUND 950-2043 ND-1 POST PURGE BURNER KIT 8504004 REV 0196 user guide will be useful to you.


TJERNLUND 950-2043 ND-1 POST PURGE BURNER KIT 8504004 REV 0196 : Download the complete user guide (212 Ko)

Manual abstract: user guide TJERNLUND 950-2043 ND-1 POST PURGE BURNER KIT 8504004 REV 0196

Detailed instructions for use are in the User's Guide.

[. . . ] TJERNLUND PRODUCTS, INC. 1601 Ninth Street · White Bear Lake, MN 55110-6794 PHONE (800) 255-4208 · (651) 426-2993 · FAX (651) 426-9547 Visit our web site · www. tjernlund. com INSTALLATION INSTRUCTIONS FOR ND-1 (950-2043) POST PURGE BURNER KIT DIAGRAM A Make sure all power is disconnected from the furnace/boiler before attempting to install the ND-1. Failure to do so can cause electrical shock resulting in personal injury or death. [. . . ] Align the junction box extension to the top of the existing burner motor junction box. Insert and start the 2 1/2" sheet metal screws to locate the junction box extension to the existing junction box. Install the R8184G primary control and tighten the 2 1/2" sheet metal screws. DIAGRAM B PLAN VIEW ISOMETRIC VIEW DIAGRAM C Make sure all power is disconnected from the furnace/boiler before attempting to install the ND-1. Failure to do so can cause electrical shock resulting in personal injury or death. Apply pipe sealant to the Solenoid Elbows, insert and tighten to position necessary for oil tubing. If Oil Tubing does not reach pump and burner chamber the installer must provide a means of mounting the Solenoid Bracket on an extension. If mounting on a boiler attach Solenoid to exterior boiler wall with the 3/8" self tapping screws using the larger holes in Bracket, (See Diagram C). If mounting on a furnace install Solenoid on interior wall with the 3/8" self tapping screws using the smaller holes in Bracket, (See Diagram D). from the Valve to the nozzle line paying attention to the direction of flow as shown, (See Diagram E). The 24" long 3/8" diameter metal Conduit will have to be added to accommodate the placement of the Solenoid Valve on the wall of the appliance. Thread wires through metal conduit for connection to primary control. DIAGRAM D INSTALLATION OF RELAY AND JUNCTION BOX EXTENSION ON NON-BECKETT BURNERS (DIAGRAM E) 1. [. . . ] SIDESHOT® WIRED WITH STANDARD HONEYWELL ST9103 CONTROL & BURNER MOTOR POST PURGE SIDESHOT TERMINAL STRIP FURNACE TERMINAL STRIP THERMOSTAT TERMINAL STRIP HST-SERIES WIRED WITH HONEYWELL ST9103 CONTROL AND BURNER MOTOR POST PURGE KIT SIDESHOT® OR HST-SERIES WIRED WITH BURNER MOTOR POST PURGE KIT SIDESHOT® OR HST-SERIES WIRED WITH PHELON CONTROL AND BURNER MOTOR POST PURGE KIT REPLACEMENT PARTS OIL SOLENOID 115V RELAY REV. 1/96 PART# 950-0690 PART# 950-0695 Copyright © 1995 Tjernlund Products, Inc. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TJERNLUND 950-2043 ND-1 POST PURGE BURNER KIT 8504004 REV 0196




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual TJERNLUND 950-2043 ND-1 POST PURGE BURNER KIT 8504004 REV 0196 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.