If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual TJERNLUND 950-0484 MAC-3 BOARD KIT 8505009 REV. 0800. We hope that this TJERNLUND 950-0484 MAC-3 BOARD KIT 8505009 REV. 0800 user guide will be useful to you.


TJERNLUND 950-0484 MAC-3 BOARD KIT 8505009 REV. 0800 : Download the complete user guide (352 Ko)

Manual abstract: user guide TJERNLUND 950-0484 MAC-3 BOARD KIT 8505009 REV. 0800

Detailed instructions for use are in the User's Guide.

[. . . ] Red wires from High Limit must be connected to Auxiliary Limit (9 & 0) contacts. Gray wires from Alarm Sequencer must be connected to Alarm Sequencer (5 & 6) contacts. Black and White wires from Alarm Sequencer must be connected to Alarm Sequencer (7 & 8) contacts. IMPORTANT: Jumper wire must be installed across H & PH terminals when IN-FORCER Fan Prover is wired into Auxiliary Prover (3 & 4) contacts. It is not necessary to wire the Fan Prover in series with the H & PH terminals as shown in the MAC-3 Instructions enclosed when the Prover is wired in series with the Auxiliary Prover (3 & 4) contacts. [. . . ] Recognize this symbol as an indication of important Safety Information! THESE INSTRUCTIONS ARE INTENDED AS AN AID TO QUALIFIED, LICENSED SERVICE PERSONNEL FOR PROPER INSTALLATION, ADJUSTMENT AND OPERATION OF THIS UNIT. READ THESE INSTRUCTIONS THOROUGHLY BEFORE ATTEMPTING INSTALLATION OR OPERATION. FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN IMPROPER INSTALLATION, ADJUSTMENT, SERVICE OR MAINTENANCE POSSIBLY RESULTING IN FIRE, ELECTRICAL SHOCK, CARBON MONOXIDE POISONING, EXPLOSION, OR PERSONAL INJURY OR PROPERTY DAMAGE. PLEASE READ CAREFULLY AND KEEP ON JOB SITE FOR FUTURE REFERENCE. Copyright © 1999, Tjernlund Products, Inc. Failure to install, maintain and/or operate the MAC-3 in accordance with manufacturer's instructions may result in conditions that can produce bodily injury and property damage. The safety interlock and system operation performance checks must be performed on each appliance interlocked with the MAC-3 in accordance with the Power Venter, Draft Inducer, IN-FORCER or Damper installation instructions. ELECTRICAL All wiring from the MAC-3 to the appliance must be appropriate Class 1 wiring as follows: installed in rigid metal conduit, intermediate conduit, rigid non-metallic conduit, electrical metallic tubing, Type MI Cable, Type MC Cable or be otherwise suitably protected from physical damage. The disconnect means and circuit protection are to be provided by the installer of this device. SEQUENCE OF OPERATION OF MAC-3 INTERLOCKED WITH 24 VAC & 115 VAC APPLIANCE CONTROL CIRCUITS The circuit board of the MAC-3 is designed for a simple three wire interlock with up to three separate burners. Upon a call for heat the "hot" leg of the burner circuit is intercepted and routed to the MAC-3 terminal strip. The MAC-3 is activated, the power venter, draft inducer, IN-FORCER or damper starts. The proving switch makes and the intercepted "hot" leg is returned to the burner circuit, allowing the burner to fire. Plug-in relays must be purchased separately depending on control system voltage of appliance. Use Tjernlund part # 950-1040 relay For 24 VAC control systems Use Tjernlund part # 950-0480 relay For 115 VAC control systems ELECTRICAL SPECIFICATIONS TABLE MAC-3 CIRCUIT BOARD FEATURES Aux. Limit switch in series with optional limit on terminal strip Optional Alarm Sequencer proves Fan Prover Operation (not limit operation) Appliance # 3 Interlock Used in conjunction with Optional Alarm Sequencer Optional Limit (Spill Switch) 115 VAC Proven "HOT" From Fan Prover Appliance # 2 Interlock 115 VAC Neutral To Inducer / Venter / IN-FORCER 115 VAC "HOT" To Inducer / Venter / IN-FORCER motor & Fan Prover Auxiliary Operation Switch (i. e. Manual or Gas Pressure) Appliance # 1 Interlock 115 VAC Input From Disconnect Switch Aux. Prover contacts in series with H & PH contacts on output terminals Aux. Motor in parallel with H & N used for additional Power Venter, Inducer, IN-FORCER 1 OUTPUT POWER VENTER, DRAFT INDUCER, IN-FORCER & DAMPER WIRING WITH THE MAC-3 When wiring the MAC-3 with a Tjernlund Power Venter without a post-purge Timer/Relay only the Fan Proving Switch and motor leads are utilized for wiring. If you are wiring with a post purge Timer/Relay see wiring on bottom of page 2. Our HSUL Series, GPAK-J/1 Series and Commercial HS-3, 4, 5 Series utilize our part # 950-1040 relays which can be plugged into the MAC-3 for 24V control systems. The HSUL-Series, GPAK-J/1 Series and model HS-5 include one part # 950-1040 relay. [. . . ] 2. ) After the faulty component is determined, return it to your Tjernlund distributor for replacement. If MAC-3 date code is older than 18 months you will need to provide a copy of the original installation receipt to your distributor. Credit or replacement will only be issued to a Tjernlund distributor after the defective part has been returned prepaid to Tjernlund. REPLACEMENT PARTS COVERED BY WARRANTY 24 Volt Relay 115 Volt Relay 4PDT Isolation Relay Alarm Sequencer Circuit Board only 950-1040 950-0480 950-0481 950-0478 950-0484 WHAT IS NOT COVERED Product installed contrary to our installation instructions Product that has been altered, neglected or misused Product that has been wired incorrectly Any freight charges related to the return of the defective part Any labor charges related to evaluating and replacing the defective part TJERNLUND LIMITED ONE YEAR WARRANTY Tjernlund Products, Inc. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TJERNLUND 950-0484 MAC-3 BOARD KIT 8505009 REV. 0800




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual TJERNLUND 950-0484 MAC-3 BOARD KIT 8505009 REV. 0800 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.