User manual TJERNLUND 950-0020 115V COOLING FAN 8504073 REV. A 0906

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual TJERNLUND 950-0020 115V COOLING FAN 8504073 REV. A 0906. We hope that this TJERNLUND 950-0020 115V COOLING FAN 8504073 REV. A 0906 user guide will be useful to you.


TJERNLUND 950-0020 115V COOLING FAN 8504073 REV. A 0906 : Download the complete user guide (280 Ko)

Manual abstract: user guide TJERNLUND 950-0020 115V COOLING FAN 8504073 REV. A 0906

Detailed instructions for use are in the User's Guide.

[. . . ] TJERNLUND PRODUCTS, INC. 1601 Ninth Street · White Bear Lake, MN 55110-6794 PHONE (800) 255-4208 · (651) 426-2993 · FAX (651) 426-9547 Visit our web site · www. tjernlund. com (950-0020) 115 VAC FAN REPLACEMENT INSTRUCTIONS FOR SS2 SIDESHOT® VENT SYSTEMS SEE INSTRUCTIONS BELOW Disconnect power supply before servicing SS2 to prevent electrical shock and equipment damage. Slide venter assembly out of vent cabinet and lay on its side on a flat working surface, (See Diagram B). [. . . ] Important: Note setting of dehumidistat (if equipped) so it can be reset when finished. Use caution and drill out (4) rivets from exterior and interior guard of defective fan with a 5/32" drill bit, (See Diagram D). DIAGRAM D Model V1 Shown Drill out (4) rivets on interior and exterior fan housing with 5/32" drill bit. EXTERIOR VIEW INTERIOR VIEW 3. IMPORTANT: Make sure air flow arrow is directed to the exterior side of mounting plate so air flows from the crawl space to outdoors. Insert (4) 8-32 x 1/2" studs through fan flange, mounting plate and exterior fan guard. Insert (4) 8-32 x 1/2" studs through fan flange and tighten (4) keps nuts to secure interior fan guard on fan. Replace BLACK and WHITE motor leads and reinstall Crawl Space Ventilator in opening. Reestablish 115 VAC power and cycle Crawl Space Ventilator "on" to verify proper operation. NOTE: If outside temperature is below 50oF, T-stat may not allow Ventilator to turn on. FOR AUTO-DRAFT® INDUCERS WITH 115 VAC COOLING FANS SEE INSTRUCTIONS BELOW Remove any appliance calls for heat and disconnect power to Auto-Draft® Inducer and appliances before servicing. Remove (2) screws from each Auto-Draft exterior housing side (12 total), (See Diagram E). [. . . ] Run Inducer through a couple of heating cycles to verify proper operation. DIAGRAM F Remove Cooling Fan motor leads Important: Cooling Fan air flow direction Remove (2) nuts which secure Cooling Fan to motor cowling DIAGRAM G DIAGRAM E Remove (2) screws from each Auto-Draft housing side Remove (2) screws from each Auto-Draft motor cowling side [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TJERNLUND 950-0020 115V COOLING FAN 8504073 REV. A 0906




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual TJERNLUND 950-0020 115V COOLING FAN 8504073 REV. A 0906 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.