User manual SMC 8724M INT

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SMC 8724M INT. We hope that this SMC 8724M INT user guide will be useful to you.


SMC 8724M INT : Download the complete user guide (2433 Ko)

You may also download the following manuals related to this product:

   SMC 8724M INT annexe 1 (6064 ko)
   SMC 8724M INT FICHE TECHNIQUE (118 ko)

Manual abstract: user guide SMC 8724M INT

Detailed instructions for use are in the User's Guide.

[. . . ] TigerStack 10G Gigabit Ethernet Switch 24/48 auto-MDI/MDI-X 10/100/1000BASE-T ports 4 ports shared with 4 SFP transceiver slots Non-blocking switching architecture Support for a redundant power unit Spanning Tree Protocol, RSTP, and MSTP Up to 32 LACP or static 8-port trunks Layer 2/3/4 CoS support through eight priority queues Layer 3/4 traffic priority with IP Precedence and IP DSCP Full support for VLANs with GVRP IGMP multicast filtering and snooping Support for jumbo frames up to 9 KB Manageable via console, Web, SNMP/RMON Installation Guide SMC8724M SMC8748M TigerStack 10G Installation Guide From SMC's Tiger line of feature-rich workgroup LAN solutions 38 Tesla Irvine, CA 92618 Phone: (949) 679-8000 October 2004 Pub. However, no responsibility is assumed by SMC for its use, nor for any infringements of patents or other rights of third parties which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of SMC. SMC reserves the right to change specifications at any time without notice. [. . . ] The switches also support multiple spanning trees which allow VLAN groups to maintain a more stable path between all VLAN members. This can reduce the overall amount of protocol traffic crossing the network, and provide a shorter reconfiguration time if any link in the spanning tree fails. R&D 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Stack Master 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 Master Select Stack ID Stack Link Power RPU Diag VLAN 1 Tagged Ports 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 Module Console Untagged Ports VLAN unaware switch Tagged Port VLAN aware switch R&D Finance VLAN 2 Testing Marketing Finance Testing VLAN 3 VLAN 4 VLAN 3 VLAN 1 VLAN 2 Figure 2-4 Making VLAN Connections Note: When connecting to a switch that does not support IEEE 802. 1Q VLAN tags, use untagged ports. 2-5 NETWORK PLANNING Application Notes 1. Full-duplex operation only applies to point-to-point access (such as when a switch is attached to a workstation, server or another switch). When the switch is connected to a hub, both devices must operate in half-duplex mode. Avoid using flow control on a port connected to a hub unless it is actually required to solve a problem. Otherwise back pressure jamming signals may degrade overall performance for the segment attached to the hub. As a general rule the length of fiber optic cable for a single switched link should not exceed: · · · 1000BASE-SX: 550 m (1805 ft) for MMF 1000BASE-LX: 5 km (3. 1 miles) for SMF 1000BASE-ZX: 100 km (62. 1 miles) for SMF However, power budget constraints must also be considered when calculating the maximum cable length for your specific environment. 2-6 CHAPTER 3 INSTALLING THE SWITCH Selecting a Site TigerStack 10G units can be mounted in a standard 19-inch equipment rack or on a flat surface. The site should: · · · · · be at the center of all the devices you want to link and near a power outlet. be able to maintain its temperature within 0 to 50 °C (32 to 122 °F) and its humidity within 5% to 95%, non-condensing provide adequate space (approximately two inches) on all sides for proper air flow be accessible for installing, cabling and maintaining the devices allow the status LEDs to be clearly visible Make sure twisted-pair cable is always routed away from power lines, fluorescent lighting fixtures and other sources of electrical interference, such as radios and transmitters. Make sure that a separate grounded power outlet that provides 100 to 240 VAC, 50 to 60 Hz, is within 2. 44 m (8 feet) of each device and is powered from an independent circuit breaker. As with any equipment, using a filter or surge suppressor is recommended. 3-1 INSTALLING THE SWITCH Ethernet Cabling To ensure proper operation when installing the switches into a network, make sure that the current cables are suitable for 10BASE-T, 100BASE-TX or 1000BASE-T operation. Check the following criteria against the current installation of your network: Cable type: Unshielded twisted pair (UTP) or shielded twisted pair (STP) cables with RJ-45 connectors; Category 3 or better for 10BASE-T, Category 5 or better for 100BASE-TX, and Category 5e, 6 or better for 1000BASE-T. Protection from radio frequency interference emissions Electrical surge suppression Separation of electrical wires (switch related or other) and electromagnetic fields from data based network wiring Safe connections with no damaged cables, connectors or shields RJ-45 Connector Figure 3-1 RJ-45 Connections 3-2 EQUIPMENT CHECKLIST Equipment Checklist After unpacking the TigerStack 10G unit, check the contents to be sure you have received all the components. Then, before beginning the installation, be sure you have all other necessary installation equipment. Package Contents TigerStack 10G unit (SMC8724M or SMC8748M) Four adhesive foot pads Bracket Mounting Kit containing two brackets and eight screws for attaching the brackets to the switch Power cord--either US, Continental Europe or UK RS-232 console cable This Installation Guide Management Guide SMC Warranty Registration Card--be sure to complete and return to SMC Optional Rack-Mounting Equipment If you plan to rack-mount the switch, be sure to have the following equipment available: Four mounting screws for each device you plan to install in a rack--these are not included A screwdriver (Phillips or flathead, depending on the type of screws used) 3-3 INSTALLING THE SWITCH Mounting A TigerStack 10G unit can be mounted in a standard 19-inch equipment rack or on a desktop or shelf. Mounting instructions for each type of site follow. Rack Mounting Before rack mounting the switch, pay particular attention to the following factors: Temperature: Since the temperature within a rack assembly may be higher than the ambient room temperature, check that the rack-environment temperature is within the specified operating temperature range. (See page C-2. ) Mechanical Loading: Do not place any equipment on top of a rack-mounted unit. Circuit Overloading: Be sure that the supply circuit to the rack assembly is not overloaded. Particular attention should be given to supply connections other than direct connections to the mains. 3-4 MOUNTING To rack-mount devices: 1. Attach the brackets to the device using the screws provided in the Bracket Mounting Kit. 46 47 48 Mas ter Stac k ID Stack Stack Ma Link ster Powe RPU r 45 Modu le Diag 46 47 Cons ole 48 Figure 3-2 Attaching the Brackets 2. Mount the device in the rack, using four rack-mounting screws (not provided). 46 47 48 Maste Selec r t Stack ID Stac Stack Mas k Link ter Pow er RPU 45 Modul e Diag 46 47 Cons ole 48 Figure 3-3 Installing the Switch in a Rack 3-5 INSTALLING THE SWITCH 3. If installing a single switch only, turn to "Connecting to a Power Source" at the end of this chapter. If installing multiple switches, mount them in the rack, one below the other, in any order. [. . . ] CSMA/CD CSMA/CD (Carrier Sense Multiple Access/Collision Detect) is the communication method employed by Ethernet, Fast Ethernet, or Gigabit Ethernet. End Station A workstation, server, or other device that does not forward traffic. Ethernet A network communication system developed and standardized by DEC, Intel, and Xerox, using baseband transmission, CSMA/CD access, logical bus topology, and coaxial cable. The successor IEEE 802. 3 standard provides for integration into the OSI model and extends the physical layer and media with repeaters and implementations that operate on fiber, thin coax and twisted-pair cable. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SMC 8724M INT




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SMC 8724M INT will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.