User manual SHARP AF-S125EX

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SHARP AF-S125EX. We hope that this SHARP AF-S125EX user guide will be useful to you.


SHARP AF-S125EX : Download the complete user guide (1135 Ko)

Manual abstract: user guide SHARP AF-S125EX

Detailed instructions for use are in the User's Guide.

[. . . ] ROOM AIR CONDITIONER INSTALLATION AND OPERATION MANUAL AF-S100EX AF-S120EX AF-S125EX AF-R100EX AF-R120EX CONTENTS PAGE FOR YOUR PROTECTION . . . . . . . . . . . . . . . . . . . . 3 INSTALLATION INSTRUCTIONS · CHECK WINDOW AREA . . . . . . . . . . . . . . . . . . . . . . . . 4 4 5 5 5 PRECAUTIONS · CAUTION FOR USE . . . . . . . . . . . . . . . . . . . . . . . . . . . . · ENERGY EFFICIENCY TIPS . . . . . . . . . . . . . . . 8 8 9 9 This INSTALLATION AND OPERATION MANUAL explains the proper use of your new Sharp Air Conditioner. [. . . ] Freezing can occur when the temperature is set close to 64°F and when there are low outside temperatures, especially during the night hours. At these conditions, a further temperature drop may cause the unit to freeze. Setting the unit to a higher temperature will prevent it from freezing. ENERGY EFFICIENCY TIPS · Setting the proper temperature. For optimum energy efficiency, keep the difference between the inside and outside temperature within 10°F(5°C). Do not keep the temperature setting any lower than is necessary for you to feel comfortable. Generally, 78°F to 80°F(26°C to 27°C) is a comfortable summer indoor temperature. When you turn the unit on, do not set the temperature higher than the room temperature at start up as this will not allow the compressor to cycle and maintain a comfortable room temperature. · Avoid direct sunlight. Close blinds, drapes or shades to keep out direct sunlight during cooling operation. · Keep the filter clean. Keeping the filter clean greatly aids efficient operation. A dirty filter blocks the flow of air, making your air conditioner work harder and less efficiently. See page 18 on how to clean the filter. · Turn off unnecessary light. Your air conditioner must remove the heat produced by your lights or other heat-producing appliances. Turn off lights or appliances that are not in use. · Install your air conditioner in a shady location. Direct sunlight on a window air conditioner increases its workload and will increase its operating cost. · Don't let cool air escape. Close windows and outside doors. Improperly installed air conditioners and improperly weatherstripped doors and windows will let hot air in and the cool air out. · Turn off air conditioner when no one is home. Use only when necessary. The fewer hours a room air conditioner is used, the lower the operating cost. · Disconnect the power cord when the unit is not used for an extended period of time. The unit still consumes a small amount of power when it is not operating. 9 HOW TO OPERATE PARTS NAMES UNIT 4 3 5 6 7 8 9 10 11 12 2 1 1 2 13 8 9 10 3 4 5 6 7 Front panel Air inlet (Indoor side) Vertical louvers Horizontal louvers Air outlet (Indoor side) Exhaust lever Control panel 11 12 13 Cabinet Air outlet (Outdoor side) Air inlet (Outdoor side) Filter handle Filter (Pull the filter handle to the right to remove. ) Power cord CONTROL PANEL F hr ! SLEEP COOL TEMP TIMER ON/OFF SELECTOR ENERGY SAVER POWER ON/OFF "# $ % & ' 7 TIMER ON/OFF pad 1 Receiver window for remote control signal 2 Display 3 SLEEP indicator 4 SELECTOR pad 5 COOL indicator 6 TEMPERATURE setting pad ----Lower 8 TIMER indicator 9 ENERGY SAVER pad 10 ENERGY SAVER indicator 11 POWER ON/OFF pad 12 POWER indicator temp. ----Raise temp. 10 HOW TO OPERATE COOLING OPERATION COOL indicator F hr SLEEP COOL TEMP TIMER ON/OFF POWER indicator 1 2 Touch POWER ON/OFF pad. · The unit is preset at 74°F and HIGH COOL. · POWER indicator and COOL indicator will light. SELECTOR ENERGY SAVER POWER ON/OFF To turn off the unit, touch POWER ON/OFF pad again. · POWER indicator and COOL indicator will go off. POWER ON/OFF pad TO CHANGE FAN SPEED AND OPERATION MODE COOL indicator F hr SLEEP COOL TEMP TIMER ON/OFF During operation Touch SELECTOR pad and select the operation mode and fan speed. · Fan speed and operation mode will change as you touch. ENERGY SAVER SELECTOR POWER ON/OFF HIGH COOL LOW FAN MED COOL MED FAN LOW COOL HIGH FAN SELECTOR pad NOTES ON OPERATION MODE: MODE HIGH COOL MED COOL LOW COOL HIGH FAN MED FAN LOW FAN COOL indicator light on light on light on light off light off light off DISPLAY Cooling operation with high fan speed. Fan only operation with low fan speed. · When the SELECTOR is changed to fan only operation from cooling operation, it will take 5 seconds for the compressor to stop. 11 HOW TO OPERATE TO CHANGE TEMPERATURE SETTING During cooling operation F hr SLEEP COOL TEMP TIMER ON/OFF Touch the TEMPERATURE setting pad to adjust the temperature setting. ENERGY SAVER SELECTOR POWER ON/OFF temp. · Temperature can be set within the range of 64°F to 86°F. ---Lower TEMPERATURE setting pad · Display will change as you touch the pad. NOTES: · In fan only (HIGH FAN, MED FAN, LOW FAN) operation, the temperature display will go off and the temperature setting cannot be changed. · In cases of power outages or when the unit is disconnected; when the power is restored or the unit is plugged in, the unit and display will return to the preset conditions of 74°F and HIGH COOL. The user must touch POWER ON/OFF to resume operation. TO CHANGE AIR FLOW DIRECTION The horizontal louvers are used to adjust the UP/DOWN direction of air flow, and the vertical louvers are used to adjust the LEFT/RIGHT direction of air flow for uniform and efficient cooling of the room. Horizontal louvers Vertical louvers Vertical louver levers Adjust UP/DOWN air flow Adjust LEFT/RIGHT air flow EXHAUST If air in your room is stale, set the EXHAUST lever to the OPEN position. The EXHAUST lever should normally be kept in the CLOSED position during cooling for maximum efficiency. EXHAUST Lever CLOSED OPEN 12 HOW TO OPERATE ENERGY SAVER OPERATION During normal operation, the thermostat automatically controls cooling and the fan runs continuously. When the ENERGY SAVER OPERATION is selected, the thermostat automatically controls cooling and the fan automatically stops when the compressor is not operating. This will occur within a 20 min time span. ) ENERGY SAVER indicator F hr SLEEP COOL TEMP TIMER ON/OFF During cooling operation 1 ENERGY SAVER Touch ENERGY SAVER pad. · ENERGY SAVER indicator will light. SELECTOR POWER ON/OFF 2 To cancel, touch ENERGY SAVER pad again. · ENERGY SAVER indicator will go off. ENERGY SAVER pad NOTE: ENERGY SAVER OPERATION cannot be set during fan only operation. SLEEP OPERATION When SLEEP OPERATION is set, the temperature setting is automatically adjusted to prevent the room from becoming too cold while you sleep. One hour after the SLEEP OPERATION is started, the temperature setting rises 2°F higher than the original temperature setting. Temperature display on the unit will not change from its original setting. During cooling operation SLEEP indicator F hr SLEEP COOL TEMP TIMER ON/OFF 1 ENERGY SAVER Press the SLEEP button on the remote control. SLEEP · SLEEP indicator will light. POWER ON/OFF SELECTOR 2 To cancel, press the SLEEP button again. · SLEEP indicator will go off. NOTE: · SLEEP OPERATION cannot be set during fan only operation. [. . . ] It can only be activated by the TIMER ON/OFF pad on the unit's control panel ( See page 14 ). SLEEP button Push to start or cancel the SLEEP OPERATION( See page 13). Light absorbing material is used for the Power ON/OFF and TEMP buttons. Keep the remote control in a lighted place for several hours in order for the buttons to absorb light. The buttons will glow for approximately two hours and the duration may differ depending on various conditions. 17 ENERGY EFFICIENCY TIPS CLEANING AND MAINTENANCE CLEANING THE FILTER If the filter is clogged with dust, the amount of air flow will be reduced, resulting in poor cooling performance. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SHARP AF-S125EX




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SHARP AF-S125EX will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.