[. . . ] AF-08ERL
ROOM AIR CONDITIONER
INSTALLATION AND OPERATION MANUAL
CONTENTS
PAGE
FOR YOUR PROTECTION . . . . . . . . . . . . . . . . . . . . 3 INSTALLATION INSTRUCTIONS
· CHECK WINDOW AREA . . . . . . . . . . . . . . . . . . . . . . . . 4 4 5 5 6
PRECAUTIONS · CAUTION FOR USE . . . . . . . . . . . . . . . . . . . . . . . . . . . . · ENERGY EFFICIENCY TIPS . . . . . . . . . . . . . . .
8 8 9 9
This INSTALLATION AND OPERATION MANUAL explains the proper use of your new Sharp Air Conditioner. [. . . ] The marked rating of the extension cord should be AC 125 Volt, 15 Amp or more. Consult a qualified electrician or serviceman if the grounding instructions are not completely understood, or if doubt exists as to whether the appliance is properly grounded. If a grounding adapter is used, make sure the receptacle box is fully grounded.
3-Pronged receptacle Grounding adapter Grounded receptacle box
3-Pronged plug Grounding prong
Grounded receptacle box Screw Tab for grounding screw
Grounding wire
8
PRECAUTIONS
NOTES ON OPERATION
· Allow 3 minutes for the compressor to restart cooling.
If you turn the air conditioner off and immediately restart it, allow three minutes for the compressor to restart cooling. Improperly installed air conditioners and improperly weatherstripped doors and windows will let hot air in and the cool air out.
· Turn off air conditioner when no one is home.
Use only when necessary. The fewer hours a room air conditioner is used, the lower the operating cost.
9
HOW TO OPERATE
PARTS NAMES
UNIT
!" # $ % & '
1 Front Cabinet 2 Air Inlet (Indoor Side) 3 Horizontal Louvers 4 Vertical Louvers 5 Air Outlet (Indoor Side) 6 Control Panel 7 Rear Cabinet 8 Air Inlet (Outdoor side) 9 Filter (Pull the filter handle
to the right to remove. )
10 Filter Handle 11 Power Cord
CONTROL PANEL
F hr
!
SLEEP
COOL
TEMP
SELECTOR
TIMER
ON/OFF
ENERGY SAVER
POWER
ON/OFF
"#
$
% & '
7 TIMER ON/OFF pad
1 Receiver window for remote control signal
2 Display 3 SLEEP indicator 4 SELECTOR pad 5 COOL indicator 6 TEMPERATURE setting pad
----Lower
8 TIMER indicator 9 ENERGY SAVER pad 10 ENERGY SAVER indicator
11 POWER ON/OFF pad 12 POWER indicator
temp.
----Raise
temp.
10
HOW TO OPERATE
COOLING OPERATION
COOL indicator POWER indicator
1 2
Touch POWER ON/OFF pad.
· The unit is preset at 74°F and HIGH COOL. · POWER indicator and COOL indicator will light.
F hr
SLEEP
COOL
TEMP
SELECTOR
TIMER
ON/OFF
ENERGY SAVER
POWER
ON/OFF
To turn off the unit, touch POWER ON/OFF pad again.
· POWER indicator and COOL indicator will go off.
POWER ON/OFF pad
TO CHANGE FAN SPEED AND OPERATION MODE
COOL indicator
F hr
During operation Touch SELECTOR pad and select the operation mode and fan speed.
· Fan speed and operation mode will change as you touch.
TIMER
ON/OFF
SLEEP
COOL
TEMP
SELECTOR
ENERGY SAVER
POWER
ON/OFF
HIGH COOL LOW FAN
MED COOL MED FAN
LOW COOL HIGH FAN
SELECTOR pad
NOTES ON OPERATION MODE:
MODE HIGH COOL MED COOL LOW COOL HIGH FAN MED FAN LOW FAN COOL indicator light on light on light on light off light off light off DISPLAY
Cooling operation with high fan speed. Fan only operation with low fan speed.
· When the SELECTOR is changed to fan only operation from cooling operation, it will take 5 seconds for the compressor to stop.
11
HOW TO OPERATE
TO CHANGE TEMPERATURE SETTING
During cooling operation
F hr
Touch the TEMPERATURE setting pad to adjust the temperature setting.
TIMER
ON/OFF
SLEEP
COOL
TEMP
SELECTOR
ENERGY SAVER
POWER
ON/OFF
temp. · Temperature can be set within the range of 64°F to 86°F.
---Lower
TEMPERATURE setting pad
· Display will change as you touch the pad.
NOTE: · In fan only (HIGH FAN, MED FAN, LOW FAN) operation, the temperature display will go off and the temperature setting cannot be changed. · In cases of power outages or when the unit is disconnected; when the power is restored or the unit is plugged in, the unit and display will return to the preset conditions of 74°F and HIGH COOL. The user must touch POWER ON/OFF to resume operation.
TO CHANGE AIR FLOW DIRECTION
The horizontal louvers are used to adjust the UP / DOWN direction of air flow, and the vertical louvers are used to adjust the LEFT / RIGHT direction of air flow for uniform and efficient cooling of the room.
Horizontal louvers
Vertical louvers
Lever Adjust UP/DOWN air flow Adjust LEFT/RIGHT air flow
12
HOW TO OPERATE
ENERGY SAVER OPERATION
During normal operation, the thermostat automatically controls cooling and the fan runs continuously. When the ENERGY SAVER OPERATION is selected, the thermostat automatically controls cooling and the fan automatically stops when the compressor is not operating. This will occur within a 20 min time span. )
ENERGY SAVER indicator
F hr
During cooling operation
1
TIMER
ON/OFF
Touch ENERGY SAVER pad.
· ENERGY SAVER indicator will light.
SLEEP
COOL
TEMP
SELECTOR
ENERGY SAVER
POWER
ON/OFF
2
To cancel, touch ENERGY SAVER pad again.
· ENERGY SAVER indicator will go off.
ENERGY SAVER pad
NOTE: ENERGY SAVER OPERATION cannot be set during fan only operation.
SLEEP OPERATION
When SLEEP OPERATION is set, the temperature setting is automatically adjusted to prevent the room from becoming too cold while you sleep. One hour after the SLEEP OPERATION is started, the temperature setting rises 2°F higher than the original temperature setting. The temperature will return to its original setting after 8 hours.
During cooling operation
SLEEP indicator
F hr
1
TIMER
ON/OFF
Press the SLEEP button on the remote control.
SLEEP
SLEEP
COOL
TEMP
SELECTOR
ENERGY SAVER
POWER
ON/OFF
· SLEEP indicator will light.
2
To cancel, press the SLEEP button again.
· SLEEP indicator will go off.
NOTE: · SLEEP OPERATION cannot be set during fan only operation. · SLEEP OPERATION will be cancelled in 5 seconds, when cooling operation is changed to fan only operation while SLEEP OPERATION is set.
13
HOW TO OPERATE
ON TIMER OPERATION
· This unit has a built-in timer that can be programmed to start the unit up to 12 hours in advance. You can set the timer to start in increments of 30 minutes (0. 5 hours) up to 9. 5 hours in advance of the start time, or in 1 hour increments from 10 to 12 hours in advance of the start time. · The unit will start automatically according to your setting.
When the unit is not operating
COOL indicator
1
Touch the TIMER ON/OFF pad to set the delayed start time.
· The time setting will change as you touch the pad. The display will change as follows;
F hr
Preset(0. 5h) Previous setting
0. 5h
1. 0h
1. 5h 12h
10h 11h
SLEEP
COOL
TEMP
CL(cancel)
SELECTOR
TIMER
ON/OFF
ENERGY SAVER
POWER
ON/OFF
TIMER ON/OFF pad TIMER indicator
(If you wish to start the operation 6 hours and 30 minutes later, set the delay time as shown above. )
· The timer will be set, 5 seconds after the TIMER ON/OFF pad is touched for the last time. · Cool indicator will light when cooling operation is selected. [. . . ] It can only be activated by the TIMER ON/OFF pad on the unit's control panel ( See page 14 ).
SLEEP button
Push to start or cancel the SLEEP OPERATION( See page 13). Light absorbing material is used for the Power ON/OFF and TEMP buttons. Keep the remote control in a lighted place for several hours in order for the buttons to absorb light. The buttons will glow for approximately two hours and the duration may differ depending on various conditions.
17
CLEANING AND MAINTENANCE
CLEANING THE FILTER
If the filter is clogged with dust, the amount of air flow will be reduced, resulting in poor cooling performance. [. . . ]