Detailed instructions for use are in the User's Guide.
[. . . ] When three seconds pass without [PITCH] being pressed, the setting is stored and the tuner returns to its normal mode. By every single touch of the [PITCH], number of the moving light can be changed.
Restoring the Original Factory Settings (Factory Reset)
You can reset the various settings you have saved to the TU-12's memory and restore the the original settings that the tuner had at the time it was shipped. Hold down [MODE] and turn on the power (plug the instrument into the INPUT jack). The green light at the center of the meter lights up.
3.
11 12 13 14 15
*
16
17 18
19
1. [. . . ] The green light at the center of the meter flashes three times, and the TU-12 returns to its normal mode, with the original default factory settings restored.
Owner's Manual
Thank you, and congratulations on your choice of the BOSS TU-12 Stage Tuner. Before using this unit, carefully read the sections entitled: "USING THE UNIT SAFELY" and "IMPORTANT NOTES" (supplied on a separate sheet). These sections provide important information concerning the proper operation of the unit. Additionally, in order to feel assured that you have gained a good grasp of every feature provided by your new unit, this manual should be read in its entirety. The manual should be saved and kept on hand as a convenient reference. No part of this publication may be reproduced in any form without the written permission of BOSS CORPORATION.
Storefront Demo Display
Turn off the power (unplug the instrument from the INPUT jack). Hold down [FLAT TUNING] and turn on the power (plug the instrument into the INPUT jack). The storefront display remains until you turn the TU-12's power off and then on again, or until you press the TUNER ON/OFF switch.
1. FLAT TUNING Button: Sets the amount the pitch is lowered in flat tunings. Tuning Guide Indicator: Indicates when the proper tuning is reached.
Pitch is flat Pitch is sharp Pitch is in tune
Main Features
· · · · · · · Ultra-smooth, accurate motion and superior brightness of the meter's large-size LEDs makes tuning fast and easy Includes the Accu-Pitch sign function, which uses the motion of the meter's lights to show when tuning is completed Choose from two selectable display modes: "CENT, " where the LED meter functions like a needle-type meter, and "STREAM, " in which the lights' stream-like motion indicates when notes are out of tune. When the unit is grounded, a slight hum may occur, depending on the particulars of your installation. If you are unsure of the connection method, contact the nearest Roland Service Center, or an authorized Roland distributor, as listed on the "Information" page. Unsuitable places for connection Water pipes (may result in shock or electrocution) Gas pipes (may result in fire or explosion) Telephone-line ground or lightning rod (may be dangerous in the event of lightning) You can use the 7-pin parallel DC cable to supply power to effects processors and other PSA adaptor-compatible gear. Connect the L-shaped DC plug to the DC OUT jack, then connect to the effects processor or other device using additional plugs as needed. Make sure that the total amount of current consumed by the TU-12 and any PSA adaptor- Cap compatible device powered by the TU-12 does not exceed 500 mA. Use a cap included with the TU-12 to cover any plug of the 7-pin parallel DC cable that is not being used. Place the AC adaptor so the side with the indicator (see illustration) faces upwards and the side with textual information faces downwards. The indicator will light when you plug the AC adaptor into an AC outlet.
*
Tuning to a Flat Tuning
Press [FLAT TUNING] to lower the actual pitch one or more semitones below the note shown in the display. Each press of the button changes the display, from no flat symbols (regular tuning) to " " (lowered one semitone), " " (lowered two semitones), and so on down to " " (lowered six semitones).
15. OUTPUT Jack
Changing the Reference Pitch
When you press [PITCH], the lowest digit of the current reference pitch ("0" when set to 440 Hz) starts to flash in the Note Name/ String Number display. Each time you press [PITCH] while the display is flashing, it changes the reference pitch by 1 Hz; you can adjust the pitch over a range from 436 Hz to 445 Hz.
*
16. Grounding Terminal
*
1. [. . . ] Each time you press [PITCH] while the display is flashing, it changes the reference pitch by 1 Hz; you can adjust the pitch over a range from 436 Hz to 445 Hz.
*
16. Grounding Terminal
*
1. 3.
Switching the Meter Display Pattern
Each time you press [DISPLAY], the meter display alternately switches between the CENT and STREAM patterns. CENT Display The light moves further to the left the more the pitch of the input note drops; as the pitch rises, the light moves further to the right. STREAM Display The movement of the light to the left or right indicates how far the input note is out of tune. [. . . ]