Detailed instructions for use are in the User's Guide.
[. . . ] OWNER'S MANUAL
MIDI SOUND GENERATOR
POWER
VOLUME
PART
INSTRUMENT
PART ALL LEVEL MUTE REVERB SC-55 MAP
INSTRUMENT
ALL
LEVEL
- SOUND Canvas PAN
PAN
127
PREVIEW (PUSH)
REVERB
0
CHORUS
64
K SHIFT
64
MIDI CH
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
CHORUS
± 0 A--
KEY SHIFT
MIDI CH
DELAY
PART
SC-88 MAP
DELAY
MIDI IN B
PHONES
VIB RATE USER INST SELECT ATTACK
VIB DEPTH CUTOFF DECAY
VIB DELAY RESONANCE RELEASE
EFX
ON/OFF
EFX TYPE
EFX PARAM PARAM
EFX VALUE VALUE
CAUTION
RISK OF ELECTRIC SHOCK DO NOT OPEN
ATTENTION: RISQUE DE CHOC ELECTRIQUE NE PAS QUVRIR
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
The lightning flash with arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of uninsulated "dangerous voltage" within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the product.
INSTRUCTIONS PERTAINING TO A RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS.
IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS
WARNING - When using electric products, basic precautions should always be followed, including the following: 1. Do not use this product near water -- for example, near a bathtub, washbowl, kitchen sink, in a wet basement, or near a swimming pool, or the like. [. . . ] The "X" symbol of the effect number indicates that this is a User effect.
PART INSTRUMENT
A01 01x Stereo-EQ
LEVEL
100
PAN
0
Chapter 5. Convenient functions
99
s Creating and saving a Patch (User Patch)
You can modify the parameter values of Parts A01 and A02 as desired, assign a Patch name, and save it. 16 Patches can be saved in the Patch number locations U01 - U16.
Patch U16 Patch Name : -USER PATCH16Write Patch U01 Patch Name :-USER PATCH01Patch 128 Patch Name : EPILOGUE Patch 001 Patch Name : RB STRAT
Parameters common to all Parts PartB16
Part B16
Load Default Setting Patch Patch Name : -SOUND CanvasParameters common to all Parts Part B16 Part A01 Default Value Default Value
Part B16 Part A03 Part A02 Part A01
Instrument Effect Part Parameter etc.
Part A03 Default Value
Default Value
*
*
All Patch parameters (p. 194) are stored. (List of parameters and procedures, p. 150) However, a distinction between GroupA and B of MIDI channels will not be stored. The MIDI channel will be saved as channel "A**" of Group A Drum set parameters are not stored in a Patch.
q Naming a User Patch
1. 3.
Press the [ALL] button to make the button indicator light, and use lr INSTRUMENT [l ][r ] to select the Patch whose name you wish to modify. Press [ALL] to load Patch.
To cancel without loading, press [MUTE].
r r Simultaneously press PAN [r ] and CHORUS [r ].
The specified character location will blink.
PART INSTRUMENT
ALL 1 RB STRAT
LEVEL
100
PAN
0
4. 5.
lr Use PART [l ][r ] to move the selected character location.
The blinking area will move.
lr Press INSTRUMENT [l ][r ] and the displayed character will change.
Select the desired character, and return to step 4. Each time you press [ALL], the character will change case as A a A a. Each time you press [SC-88MAP], the symbol will alternate & ( & (.
6.
r r Simultaneously press PAN [r ] and CHORUS [r ] to end the procedure.
* To save the User Patch name, perform the procedure of "Saving a User Patch. "
100
Chapter 5. Convenient functions
12
4
PART INSTRUMENT
ALL LEVEL MUTE REVERB SC-55 MAP SC-88 MAP
DELAY
5
PAN CHORUS
36
KEY SHIFT
MIDI CH
q Saving a User Patch
1. 3.
Make the desired settings for the parameters of Parts A01 and A02. Simultaneously press [USER INST] and [SELECT].
The display will ask "Write U. Patch01?". Press INSTRUMENT [l][r] to select the number (01 - 16) where you wish to store the settings. If you select a number in which a User Patch has already been stored, a "*" symbol will appear, such as "Write*U. Patch01?"
4.
If you wish to store the settings, press [ALL].
To cancel without storing, press [MUTE].
24
PART ALL LEVEL MUTE REVERB SC-55 MAP SC-88 MAP CHORUS PAN INSTRUMENT
KEY SHIFT
MIDI CH
3
VIB RATE USER INST SELECT ATTACK
DELAY
VIB DEPTH CUTOFF DECAY
VIB DELAY RESONANCE RELEASE
EFX
ON/OFF
EFX TYPE
EFX PARAM
EFX VALUE
To load the User Patch that was stored, use the following procedure. Once again press INSTRUMENT [r], and the User Patches will be displayed. Press the [ALL] button to load the User Patch.
PART INSTRUMENT
U01 -USER PATCH01LEVEL
100
PAN
0
Chapter 5. Convenient functions
101
s Saving a Drum Set you created (User Drum)
You can modify drum instrument parameters to your liking, and save this data as a Drum Set. You can save up to two Drum Sets, and since each set contains 128 instrumental sounds, this provides a total of 256 instrumental sounds (Drum Instruments). User Drum Sets are stored in Drum Set numbers 65 and 66 of the Native map / SC-88 map (p. 104).
* The same contents are stored in both the SC-88 and Native maps.
q Naming a User Drum Set
1. 2.
Make sure that the [ALL] indicator is dark.
If it is lit, press [ALL] to turn it off.
lr r Use PART [l ] [r ] to select a Drum Part, simultaneously press PAN [r ] r and CHORUS [r ].
The character at the cursor location will blink.
PART INSTRUMENT
SET 065*SER DRUM1
LEVEL
100
PAN
0
3. 4.
lr Use PART [l ] [r ] to move the cursor where you wish to input a character.
The blinking area will move.
lr Use INSTRUMENT [l ] [r ] to select the desired character.
Then repeat from step 3. [. . . ] Oststrasse 96, 22844 Norderstedt, GERMANY TEL: (040) 52 60090
TURKEY
ZUHAL DIS TICARET A. S. No. 37 Beyoglu - Istanbul / TURKEY TEL: (0212) 249 85 10
ASIA
CHINA
Roland Shanghai Electronics Co. , Ltd. No. 1500 Pingliang Road Shanghai 200090, CHINA TEL: (021) 5580-0800 Roland Shanghai Electronics Co. , Ltd. No. 18 3 Section Anhuaxili Chaoyang District Beijing 100011 CHINA TEL: (010) 6426-5050 Roland Shanghai Electronics Co. , Ltd. [. . . ]