User manual ROLAND CF-10

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ROLAND CF-10. We hope that this ROLAND CF-10 user guide will be useful to you.


ROLAND CF-10 : Download the complete user guide (341 Ko)

Manual abstract: user guide ROLAND CF-10

Detailed instructions for use are in the User's Guide.

[. . . ] (Initial value is ON) · For Drum Parts, these messages are not received when Rx. NOTE ON = OFF for each Instrument. · Volume messages are used to adjust the volume balance of each Part. (Initial value is ON) Pan (Controller number 10) Status BnH 2nd byte 0AH 3rd byte vvH 0H~FH (Ch. 1~16) 00H~40H~7FH (Left~Center~Right), Initial value = 40H (Center) q Polyphonic Key Pressure Status AnH 2nd byte kkH 3rd byte vvH 0H~FH (Ch. 1~16) 00H~7FH (0~127) 00H~7FH (0~127) n = MIDI channel number: vv = pan: n = MIDI channel number: kk = note number: vv = key pressure: · Not received when Rx. POLY PRESSURE (PAf) = OFF. (Initial value is ON) · The resulting effect is determined by System Exclusive messages. With the initial settings, there will be no effect. · The stereo position can be adjusted over 127 steps. [. . . ] Status F0H Data byte 41H, dev, 42H, 12H, 40H, 00H, 7FH, 00H, 41H Status F7H Explanation Byte F0H Exclusive status 41H ID number (Roland) dev Device ID (dev: 00H~1FH (1~32), Initial value is 10H (17)) 42H Model ID (GS) 12H Command ID (DT1) 40H Address MSB 00H Address 7FH Address LSB 00H Data (GS reset) 41H Checksum F7H EOX (End Of Exclusive) · When this message is received, Rx. NRPN will be ON. · There must be an interval of at least 50 ms between this message and the next. s System Exclusive Messages Status F0H F0H ii = ID number Data byte iiH, ddH, . . . . . . , eeH Status F7H dd, . . . , ee = data F7H System Exclusive Message status an ID number (manufacturer ID) to indicate the manufacturer whose Exclusive message this is. ID numbers 7EH and 7FH are extensions of the MIDI standard; Universal Non-realtime Messages (7EH) and Universal Realtime Messages (7FH). 00H~7FH (0~127) EOX (End Of Exclusive) The System Exclusive Messages Transmitted and received by the CF-10/EXR-3 are: messages related to Mode Setting, Universal Realtime System Exclusive messages, Data Requests (RQ1), and Data Set (DT1). 9 CF-10/EXR-3 MIDI Implementation 3. Individual Parameter Transmission (Model ID=42) Individual Parameter Transmission transmits data (or requests data) for one parameter as one exclusive message (one packet of "F0 . . . . . In Individual Parameter Transmission, you must use the Address and Size listed in the following "Parameter Address Map". Addresses marked at "#" cannot be used as starting addresses. s System Realtime Message q Active sensing Status FEH * This will be transmitted constantly at intervals of approximately 250 ms. s System Exclusive messages "Identity Reply" and "Data Set 1 (DT1)" are the only System Exclusive messages transmitted by the CF-10/EXR-3. When an appropriate "Identity Request Message" and "Data Request 1 (RQ1)" message are received, the requested internal data will be transmitted. Identity Reply Status F0H Byte Data byte 7EH, dev, 06H, 02H, 41H, 42H, 00H, 00H, 06H, ssH, ssH, ssH, ssH Status F7H Explanation FOH Exclusive status 7EH ID number (Universal Non-realtime Message) dev Device ID (use the same as the device ID of Roland) 06H Sub ID#1 (General Information) 02H Sub ID#2 (Identity Reply) 41H ID number (Roland) 42H Device family code (LSB) 00H Device family code (MSB) 00H Device family number code (LSB) 06H Device family number code (MSB) ssH Software revision level ssH Software revision level ssH Software revision level ssH Software revision level F7H EOX (End of Exclusive) * Reply the message by the unique device ID (dev) when the device has received the "Identity Request Message" in the Broadcast. Data set 1 Status F0H Byte Data byte 41H, dev, 42H, 12H, aaH, bbH, ccH, ddH, . . . eeH, sum DT1 (12H) Status F7H Explanation F0H Exclusive status 41H ID number (Roland) dev Device ID (dev: 00H~1FH, Initial value is 10H) 42H Model ID (GS) 12H Command ID (DT1) aaH Address MSB: upper byte of the starting address of the data to be sent bbH Address: middle byte of the starting address of the data to be sent ccH Address LSB: lower byte of the starting address of the data to be sent. 00~7F F0 41 10 42 12 40 03 00 01 11 2B F7 F0 41 10 42 12 40 03 04 01 38 F7 F0 41 10 42 12 40 03 03 4C 6E F7 F0 41 10 42 12 40 03 15 40 68 F7 Distortion Bltln Value Hex. 00~7F F0 41 10 42 12 40 03 00 01 11 2B F7 F0 41 10 42 12 40 03 04 02 37 F7 F0 41 10 42 12 40 03 03 4C 6E F7 F0 41 10 42 12 40 03 15 40 68 F7 Distortion 2-Stk Value Hex. 00~7F F0 41 10 42 12 40 03 00 01 11 2B F7 F0 41 10 42 12 40 03 04 03 36 F7 F0 41 10 42 12 40 03 03 4C 6E F7 F0 41 10 42 12 40 03 15 40 68 F7 Distortion 3-Stk (Default) Value Hex. 00~7F F0 41 10 42 12 40 03 00 01 20 1C F7 F0 41 10 42 12 40 03 03 24 16 F7 F0 41 10 42 12 40 03 04 10 29 F7 Phaser ValueHex. 00-24-7F Value Hex. 00~7F F0 41 10 42 12 40 03 00 01 21 1B F7 F0 41 10 42 12 40 03 05 44 74 F7 F0 41 10 42 12 40 03 07 28 0E F7 Auto Wah Value Hex. 00~7F F0 41 10 42 12 40 03 00 01 22 1A F7 F0 41 10 42 12 40 03 0D 00 30 F7 F0 41 10 42 12 40 03 16 7F 28 F7 Rotary (Slow) Value Hex. 00~7F F0 41 10 42 12 40 03 00 01 22 1A F7 F0 41 10 42 12 40 03 0D 7F 31 F7 F0 41 10 42 12 40 03 16 7F 28 F7 Rotary (Fast) Value Hex. 00~7F F0 41 10 42 12 40 03 00 01 23 19 F7 F0 41 10 42 12 40 03 06 0B 2C F7 F0 41 10 42 12 40 03 08 68 4D F7 Stereo Flanger Value Hex. 0F~71 F0 41 10 42 12 40 03 00 01 24 18 F7 F0 41 10 42 12 40 03 06 27 10 F7 F0 41 10 42 12 40 03 08 36 7F F7 Step Flanger Value Hex. 00~7F F0 41 10 42 12 40 03 00 01 30 0C F7 F0 41 10 42 12 40 03 15 40 68 F7 F0 41 10 42 12 40 03 16 68 3F F7 Compressor Value Hex. 00~7F F0 41 10 42 12 40 03 00 01 31 0B F7 F0 41 10 42 12 40 03 15 40 68 F7 F0 41 10 42 12 40 03 16 7F 28 F7 Limiter Value Hex. [. . . ] F7 (1) (2) (3) (4) (5) address data checksum (6) (1) Exclusive Status, (4) Model ID (GS), (2) ID (Roland), (5) Command ID (DT1), (3) Device ID (17), (6) End of Exclusive Next, we calculate the checksum. 40H+01H+30H+02H = 64+1+48+2 = 115 (sum) 115 (sum) ÷ 128 = 0 (quotient) . . . 115 (remainder) checksum = 128 - 115 (remainder) = 13 = 0DH This means that F0 41 10 42 12 40 01 30 02 0D F7 is the message we transmit. [Example 2] Setting REVERB LEVEL to 12 18 CF-10/EXR-3 MIDI Implementation According to the "Parameter Address Map (p. 248), " the REVERB LEVEL Address is 40 01 33H, and the parameter value is 0CH. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ROLAND CF-10




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ROLAND CF-10 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.