User manual NAPCO MAGNUM ALERT 3000 FIRE ALARM

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual NAPCO MAGNUM ALERT 3000 FIRE ALARM. We hope that this NAPCO MAGNUM ALERT 3000 FIRE ALARM user guide will be useful to you.


NAPCO MAGNUM ALERT 3000 FIRE ALARM : Download the complete user guide (17 Ko)

Manual abstract: user guide NAPCO MAGNUM ALERT 3000 FIRE ALARM

Detailed instructions for use are in the User's Guide.

[. . . ] The keypad will display "FIRE SILENCED, followed by "FIRE STATUS", "FIRE ALARM", FIRE DRILL TEST then "FIRE SILENCED". To terminate the test, enter code, then press Enter code and press [INFO]. The keypad will display "NOT NORMAL", indicating that the fire bell is active. [. . . ] To test the fire alarm signal devices, enter code and press [FUNCTION] until "BELL TEST" appears. TROUBLE Call for service if the fire status condition does not clear or the "SYS TBL" reminder is on. SYSTEM TROUBLE The panel will display the system trouble, the "SYS TBL" reminder will flash, and the keypad sounder will pulse. To acknowledge the FIRE ALARM system trouble, enter code and press [RESET]. The keypad will Signal devices (bells, horns, etc. ) will produce a distinctive fire-alarm silence and the system trouble description will clear. The keypad will display "FIRE" followed by the number and system trouble still exists the `SYS TBL reminder will remain on. description of the zone in alarm, then "FIRE STATUS", then "FIRE To recall the system trouble, enter code and press [FUNCTION]. Press [FUNCTION] until DISPLAY SYS TBL" appears, then press [YES]. BURGLARY ALARM Signal devices (bells, horns, etc. ) will produce a distinctive burglary FIRE TROUBLE alarm sound. The keypad will display "ALARM" followed by the The keypad will display "FIRE TROUBLE" followed by the zone number and description of the zone in alarm. number and description of the zone in trouble, the "FIRE/TBL". To reset the fire SILENCING A FIRE ALARM Enter code and press [ON/OFF] to silence the signal devices, If the trouble, enter code and press [RESET]. The keypad will silence and signal devices have been silenced and a fire alarm condition has not the fire trouble description will clear. However, if the fire trouble still been reset, "FIRE STATUS" will display, then "FIRE SILENCED". exists, the display will continue to scroll "FIRE STATUS" followed by "FIRE TROUBLE". [. . . ] Silence the alarm and reset the [FUNCTION] until "DISPLAY FIRE TBL" appears, then press [YES]. FIRE ALARM/TROUBLE CONDITIONS The keypad will constantly display the alarm/trouble conditions preSYSTEM TEST sent on the system. "FIRE STATUS" will display followed by the Hold down the [*] & [3] keys simultaneously. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE NAPCO MAGNUM ALERT 3000 FIRE ALARM




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual NAPCO MAGNUM ALERT 3000 FIRE ALARM will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.