User manual MUSTEK POWERMUST 6048 ONLINE LCD VIEWPOWER

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual MUSTEK POWERMUST 6048 ONLINE LCD. We hope that this MUSTEK POWERMUST 6048 ONLINE LCD user guide will be useful to you.


MUSTEK POWERMUST 6048 ONLINE LCD VIEWPOWER: Download the complete user guide (3927 Ko)

Manual abstract: user guide MUSTEK POWERMUST 6048 ONLINE LCDVIEWPOWER

Detailed instructions for use are in the User's Guide.

[. . . ] ViewPower User's Manual Management Software for Uninterruptible Power Supply Systems Table of Contents 1. ViewPower Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Step 1: Select Viewpower configuration>>Com. port plug and play setting. Refer to Diagram 4-8. 21 Diagram 4-8 Step 2: Click "Refresh" to reload the status of com. Step 3: Click "Forbid scanned" to stop scanning on this com. Log Setting Users can set up "Record Interval", "The max. numbers of logs for historical events" according to real situation. Step 1 Select Viewpower configuration>>Log setting. Refer to Diagram 4-9. 22 Diagram 4-9 Step 2 Enter data in the screen. Step 4 Click "Default" button to recover the default setting. 4. 1. 8. ModBus Communication Setting It will display all connected PCs through ModBus. Refer to Diagram 4-10. 23 Diagram 4-10 Step 2 Password setting/change menu for ModBus. Real-time control will be available when the ModBus password is the same to the UPS password. port is 0; Selectable baud rates are 1200, 2400, 4800, 9600, and 19200. The default setting is 1; Supported parity is ODD parity, event parity and NONE. NOTE: This function is only available for the UPS with ModBus communication port. 4. 1. 9. Certificates management If using Exchange Server for mailbox system, it's required to configure ExChange server domain name in this screen. 24 Select Viewpower configuration>> Certificates management. Local Shutdown It's shutdown setting for local PC which is directly connected to monitored UPS with communication port. This configuration enables system shutdown of local PC or to remote shut down PCs which are powered by monitored UPS. Step 1 Select UPS Setting >> Local Shutdown or click shortcut icon Diagram 4-12. Refer to 25 Diagram 4-12 NOTE: This screen may be different for different types of UPSs. Step 2 Select shutdown conditions and power-off options, set delay time to shutdown system. Step 3 Enter time for pop-up dialog before shutdown and warning interval in Warning Dialog Setting area. Step 4 Click "Apply" button to save all data. NOTE: Click "Default" button to recover the default setting. Conditions: UPS works on battery mode Local system shutdown after xx min xx sec: When clicking the checkbox, local PC will start to shut down after monitored UPS works on battery mode for xx min xx sec time. Local system shutdown when UPS is at low battery level: When clicking this checkbox, local PC will shut down when monitored UPS is at low battery level. Allows local system shutdown when UPS is scheduled off: When clicking this checkbox, the local system will shut down before monitored UPS is scheduled to 26 power off. [. . . ] "Export": Click "Export" button to save listed table to local PC in . CSV file. 4. 4. 2. 2. Event Statistics It will list down and provide all event statistics for UPSs with software installed based on time period A and time period B, and the change percentage [= 100*(B/A ­ 1)%]. 38 NOTE: Event types include UPS internal event, bypass event, battery event, software event, load event, input event, parallel system event and communication event. Step 1 Select View >> History >> Event Statistics. Users still can retrieve old data saved in the software even though the UPS is no longer connected to local system. Then click "Browse" button. The result statistics will be listed in below table according to event types. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE MUSTEK POWERMUST 6048 ONLINE LCD




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual MUSTEK POWERMUST 6048 ONLINE LCD will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.