User manual MACKIE UP4061 DATASHEET

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual MACKIE UP4061. We hope that this MACKIE UP4061 user guide will be useful to you.


MACKIE UP4061 DATASHEET: Download the complete user guide (535 Ko)

Manual abstract: user guide MACKIE UP4061DATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] Activation of the balanced input priority turns on 18Vdc (300mA) power at a barrier connector on the rear panel, which may be used to drive LEDs or relays. The unbalanced input features a paralleled output and 0/­20dB sensitivity switch. 12dB/octave Bass and Treble shelving equalization with up to 12dB of boost or cut at 100Hz and 10kHz can be applied to the output signal. [. . . ] (11. 4kg) Black painted or treated steel, white nomenclature UP4061 Noise: Equalization Output: Inputs: Audio Inputs Line Level, Balanced: Line Level, Unbalanced: Audio Outputs Number of Channels: Constant Impedance: Constant Voltage: Line Level: One 4 One each, 25V, 50V, 70V, 100V, barrier connectors Parallel to Unbalanced In, RCA connector 18Vdc (300mA) Dry contact closure Dry contact closure, barrier connectors Control Inputs & Outputs Outputs: Overload Indicator: Inputs: Priority Switch Input: Stand-by Switch Input: Controls Front Panel: Rear Panel: Power switch, master Volume, Treble shelving, Bass shelving Unbalanced input sensitivity switch, H-P Filter in/out switch, L-P Filter in/out switch, Mains Voltage Selector switch 115/230VAC (±5%), 50/60Hz, 180VA, DC (24V battery) 5A/Hr Power Supply Environment Maximum Ambient: 131°F (55°C), Non-precipitating humidity 2 O FoF46 PAGES S PAGE 3 UP 4061 - P. A. AMPLIFIER STD-BY OVERLOAD SIGNAL PEAK ON UP4061 Power Amplifier O FoF46 PAGES S PAGE EQ VOLUME HIGH 4 2 3 4 6 2 1 9 0 10 8 7 6 5 LOW 2 2 4 66 8 8 -10 +10 -10 +10 8 8 4 4 6 0 2 0 POWER + POWER INPUT 24V D. C. - D. C. FUSE POWER OUTPUTS POWER OUTPUTS INPUT COMMANDS 0 50V 70V 100V 0 4 25V PRIORITY GND BALANCED IN FILTER SERIAL NUMBER MANUFACTURING DATE STAND GND OVERL. UNBALANCED IN SENSITIVITY VOLTAGE SELECTOR RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION REPLACE WITH THE SAME TYPE FUSE AND RATING. DISCONNECT SUPPLY CORD BEFORE CHANGING FUSE WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE. REFER SERVICING TO QUALIFIED PERSONNEL. AVIS: RISQUE DE CHOC ELECTRIQUE -- NE PAS OUVRIR UTILISE UN FUSIBLE DE RECHANGE DE MÊ ME TYPE. DEBRANCHER AVANT DE REMPLACER LE FUSIBLE LINE 50/60 Hz-115/230V CONCEIVED, DESIGNED, AND MANUFACTURED BY MACKIE INDUSTRIAL · MADE IN ITALY · PATENTS PENDING · COPYRIGHT ©1999 THE FOLLOWING ARE TRADEMARKS/REGISTERED TRADEMARKS OF MACKIE DESIGN INC. : "MACKIE" "MACKIE INDUSTRIAL" & THE "RUNNING MAN" FIGURE , , OFF ON 20dB 0dB AMPLIFIER UP4061 Power Amplifier Architects' and Engineers' Specifications The power amplifier shall have a nominal output power of at least 60W RMS. It shall operate on 115VAC or 230VAC at either 50Hz or 60Hz and have its source power supplied by a detachable IEC power cord. In addition the unit shall be capable of being directly powered by a 24Vdc source such as storage batteries. The unit shall have a constant-impedance output to drive a 4 load at its rated output. It shall also have 25V, 50V, 70V and 100V constant-voltage outputs with like performance. The unit shall be capable of being remotely turned on, from a stand-by mode, with a contact closure. The amplifier shall have an active balanced input and an unbalanced input. The balanced input connection shall be made through barrier connectors. [. . . ] LED status indicators shall be provided on the front panel to indicate power, stand-by mode, signal present at the output terminals, peak signals near clipping and an overload condition. The amplifier shall be a model UP4061 manufactured by Mackie Industrial. UP4061 Electronic files for this product available at: www. mackieindustrial. com This Specification Sheet Quick-Start Manual UP4061. PDF UP4061QS. PDF www. mackieindustrial. com 16220 Wood-Red Rd. NE, Woodinville, WA 98072 USA 888. 337. 7404, fax 425. 487. 4337, industrial@mackie. com UK +44. 1268. 571. 212, fax +44. 1268. 570. 809, info@rcf-uk. com ITALY +39. 0522. 354. 111, fax +39. 0522. 926. 208, industrial@rcf. it FRANCE +33. 3. 8546. 9160, fax +33. 3. 8546. 9161, rcf. commercial@wanadoo. fr GERMANY +49. 2572. 96042. 0, fax +49. 2572. 96042. 10, industrial@mackie. de Mackie Designs continually engages in research related to product improvement. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE MACKIE UP4061




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual MACKIE UP4061 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.