User manual MACKIE MR6WT QUICK START

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual MACKIE MR6WT. We hope that this MACKIE MR6WT user guide will be useful to you.


MACKIE MR6WT QUICK START: Download the complete user guide (147 Ko)

Manual abstract: user guide MACKIE MR6WTQUICK START

Detailed instructions for use are in the User's Guide.

[. . . ] MONITOR MR6T/MR6WT Compact Full-Range Speaker Quick-Start Guide The MR6T (Black) and MR6WT (White) are a compact full-range speaker system designed for constant-voltage systems. The single 6. 3" dual-cone woofer achieves wide bandwidth and natural, smooth sound reproduction, ideal for use in business music systems and indoor/outdoor background music applications. [. . . ] Installation ­ Do not install this Mackie Industrial product in any way that is not provided for in the instruction manual. Stacking multiple units ­ To prevent the danger of falling equipment, never stack multiple units of this Mackie Industrial product unless this possibility is expressly indicated in the instructions. Respect the safety standards ­ The entire sound system must be designed in compliance with the current standards and laws regarding electrical systems. 8. Specifications ­ When installing and using this Mackie Industrial product, keep in mind the technical specifications indicated in the dedicated section of the manual. Accessories ­ Install and use this Mackie Industrial product only with the accessories specified by the manufacturer or supplied with the product. Hearing loss - Exposure to high sound levels can cause permanent hearing loss. The sound pressure level which leads to hearing loss varies considerably from one person to another, and depends on the duration of exposure. Government's Occupational Safety and Healt Administration (OSHA) has established the maximum sound pressure levels that can be with stood without causing damage, which are shown in the table below. According to the OSHA regulations, any exposure over the maximum limits indicated in the table can reduce the hearing capacity of a person. To prevent potentially dangerous exposure to high sound pressure levels, anyone subjected to such levels must use suitable protection. When a Mackie Industrial product capable of producing high sound levels is being used, it is therefore necessary to wear ear plugs or protective earphones when the limits shown in the table are exceeded. Consult the specifications provided in the instruction manual to know the maximum sound pressure (SPL) the speaker is capable of producing. Duration per day (hours) 8 6 4 3 2 1. 5 1 0. 5 0. 25 or less Sound level (dBA) 90 92 95 97 100 102 105 110 115 Typical example Duo in a small club Subway train Very loud classical music Locomotive at 50 feet Loudest parts at a rock concert 2 MONITOR 6T 10W 25W 0 50W BYPASS 4 25V 0 50V 70V 100V SERIAL NUMBER CONCEIVED, DESIGNED, AND MANUFACTURED BY MACKIE INDUSTRIAL MADE IN ITALY · COPYRIGHT ©2000 THE FOLLOWING ARE TRADEMARKS AND REGISTERED TRADEMARKS OF MACKIE DESIGN INC. : "MACKIE" , "MACKIE INDUSTRIAL" & THE "RUNNING MAN" FIGURE , INPUT Hookup MONITOR 6T 10W 25W 0 50W BYPASS 4 25V 0 50V 70V 100V MONITOR 6T 10W 25W 0 50W BYPASS 4 25V 0 50V 70V 100V OUTPUTS 25V 50V 70V 100V GND POWER AMPLIFIER + ­ + ­ 70V Connection MONITOR 6T 10W 25W 0 50W BYPASS 4 25V 0 50V 70V 100V MONITOR 6T 10W 25W 0 50W BYPASS 4 25V 0 50V 70V 100V OUTPUTS + L ­ + R ­ POWER AMPLIFIER ­ + ­ + 4 Ohm Stereo Connection 3 Rear Panel Features and Controls 1. This rotary control selects the power tap for the internal constant voltage transformer. Choices are 1W, 2. 5W, 5W, 10W, 20W, and BYPASS (used for 4 operation). [. . . ] Response (­3 dB): 200Hz-15kHz Coverage Angle (­6 dB): 90°, averaged 800Hz-16kHz Directivity Factor Q (DI): 9. 3 (9. 7), averaged 800Hz-16kHz System Sensitivity 1: 95 dB, 1W@1m Rated Maximum SPL: 118 dB @ 1 m (3. 3 ft) peak Rated Nominal Impedance: 4 (bypassed) System Input Power Rating : 50W IEC, 200W Peak Constant Voltage: 25V, 50V, 70V, 100V Power Taps: 10W, 25W, 50W 2 Physical: Enclosure: 45° back angles, high density polystyrene Attachment Inserts: 4 points M6 threaded Color: Grille: Matte black (MR6T) White (MR6WT) Matching perforated steel grille Input Connectors: Spring-loaded terminal Dimensions HxWxD: 11. 82 in x 8. 39 in x 8. 96 in (300 mm x 213 mm x 228 mm) Net Weight: 15. 0 lb (6. 8 kg) Transducer: Full Frequency: 6. 3" (160 mm) dual-cone woofer with 1. 5" (38mm) coil 1 Measured on-axis in the far field with 1 watt (2. 00V RMS @ 4 ) input and referenced to 1 meter distance using the inverse square law. 2 RMS using 20 Hz to 20 kHz, PN Spectrum, peak for 2 hours with +6 dB crest factor. 5 www. mackieindustrial. com 16220 Wood-Red Road NE, Woodinville, WA 98072 USA TEL 888. 337. 7404, FAX 425. 487. 4337, industrial@mackie. com UK +44. 1268. 571. 212, FAX +44. 1268. 570. 809 +industrial@rcf-uk. com ITALY +39. 0522. 354. 111, FAX +39. 0522. 926. 208 +industrial@rcf. it FRANCE +33. 3. 8546. 9160, FAX +33. 3. 8546. 9161 +rcf. commercial@wanadoo. fr GERMANY +49. 2572. 96042. 0, FAX +49. 2572. 96042. 10 +industrial@mackie. de Part No. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE MACKIE MR6WT




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual MACKIE MR6WT will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.