User manual MACKIE FUSSION1800

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual MACKIE FUSSION1800. We hope that this MACKIE FUSSION1800 user guide will be useful to you.


MACKIE FUSSION1800 : Download the complete user guide (761 Ko)

Manual abstract: user guide MACKIE FUSSION1800

Detailed instructions for use are in the User's Guide.

[. . . ] FUSSION 1800SA & 1800S ACTIVE SOUND REINFORCEMENT SUBWOOFER SYSTEM USER'S MANUAL CAUTION AVIS 7. Heat -- This Mackie product should be situated away from heat sources such as radiators, or other devices which produce heat. WARNING: The heatsink may reach high temperatures during standard use. To ensure proper operation, allow a minimum of 6 inches of clearance from the heatsink surface and adequate ventilation. [. . . ] 8 FUSSION 3000 CAUTION FUSE 16A / SB ON RISK OF ELECTRIC SHOCK DO NOT OPEN FUSSION 3000 CAUTION MAIN INPUT FUSE 16A / SB ON RISK OF ELECTRIC SHOCK DO NOT OPEN WARNING: THIS SURFACE MAY REACH HIGH TEMPERATURE DURING STANDARD USE. TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE THIS PANEL OR ANY ATTACHED COMPONENT. TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE. PARALLEL WARNING: THIS SURFACE MAY REACH HIGH TEMPERATURE DURING LOOP OUT HIGH PASS 85Hz - 20kHz STANDARD USE. TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE THIS PANEL OR ANY ATTACHED COMPONENT. TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE. PARALLEL LOOP OUT HIGH PASS 85Hz - 20kHz MAIN INPUT AVIS: RISQUE DE CHOC ELECTRIQUE -- NE PAS OUVRIR REPLACE WITH THE SAME TYPE FUSE AND RATING. DISCONNECT SUPPLY CORD BEFORE CHANGING FUSE SERIAL NUMBER UTILISE UN FUSIBLE DE RECHANGE DE MÊME TYPE. DEBRANCHER AVANT DE REMPLACER LE FUSIBLE MANUFACTURING DATE AVIS: RISQUE DE CHOC ELECTRIQUE -- NE PAS OUVRIR REPLACE WITH THE SAME TYPE FUSE AND RATING. DISCONNECT SUPPLY CORD BEFORE CHANGING FUSE SERIAL NUMBER UTILISE UN FUSIBLE DE RECHANGE DE MÊME TYPE. DEBRANCHER AVANT DE REMPLACER LE FUSIBLE MANUFACTURING DATE FUSE FUSE FULL RANGE 55Hz - 20kHz FULL RANGE 55Hz - 20kHz NEMA LS-20 20A-115VAC NEMA LS-20 20A-115VAC CONCEIVED, DESIGNED, AND MANUFACTURED BY MACKIE DESIGNS INC, WOODINVILLE, WA, USA AND MACKIE EUROPE · MANUFACTURED IN ITALY · COPYRIGHT ©1998 · THE FOLLOWING ARE TRADEMARKS OR REGISTERED TRADEMARKS OF MACKIE DESIGNS INC. : "MACKIE", AND THE "RUNNING MAN" FIGURE · PATENT PENDING POWER (GREEN) PROTECT (RED) PIN 1- GND / PIN 2- POS (+) / PIN 3- NEG (-) CONCEIVED, DESIGNED, AND MANUFACTURED BY MACKIE DESIGNS INC, WOODINVILLE, WA, USA AND MACKIE EUROPE · MANUFACTURED IN ITALY · COPYRIGHT ©1998 · THE FOLLOWING ARE TRADEMARKS OR REGISTERED TRADEMARKS OF MACKIE DESIGNS INC. : "MACKIE", AND THE "RUNNING MAN" FIGURE · PATENT PENDING POWER (GREEN) PROTECT (RED) PIN 1- GND / PIN 2- POS (+) / PIN 3- NEG (-) FILL OUT 85Hz - 20kHz OUTPUT LEVEL SUB-OUT 20Hz - 85Hz FILL OUT 85Hz - 20kHz OUTPUT LEVEL SUB-OUT 20Hz - 85Hz FUSSION 3000 FS TM 0 10 FUSSION 3000 FS TM 0 10 PHASE 0° 180° 0° PHASE 180° FUSSION 1800SA CAUTION NEMA LS-20 20A-115VAC POWER RISK OF ELECTRIC SHOCK DO NOT OPEN THIS SURFACE MAY REACH HIGH TEMPERATURE DURING STANDARD USE. TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE THIS PANEL OR ANY ATTACHED COMPONENT. TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE. FUSSION 1800SA CAUTION NEMA LS-20 20A-115VAC MAIN INPUT POWER RISK OF ELECTRIC SHOCK DO NOT OPEN THIS SURFACE MAY REACH HIGH TEMPERATURE DURING STANDARD USE. TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE THIS PANEL OR ANY ATTACHED COMPONENT. TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE. WARNING: WARNING: AVIS: RISQUE DE CHOC ELECTRIQUE -- NE PAS OUVRIR REPLACE WITH THE SAME TYPE FUSE AND RATING. DISCONNECT SUPPLY CORD BEFORE CHANGING FUSE SERIAL NUMBER UTILISE UN FUSIBLE DE RECHANGE DE MÊME TYPE. DEBRANCHER AVANT DE REMPLACER LE FUSIBLE MANUFACTURING DATE POWER OUT 35-85Hz AVIS: RISQUE DE CHOC ELECTRIQUE -- NE PAS OUVRIR REPLACE WITH THE SAME TYPE FUSE AND RATING. DISCONNECT SUPPLY CORD BEFORE CHANGING FUSE SERIAL NUMBER UTILISE UN FUSIBLE DE RECHANGE DE MÊME TYPE. DEBRANCHER AVANT DE REMPLACER LE FUSIBLE MANUFACTURING DATE POWER OUT 35-85Hz MAIN INPUT ON PARALLEL ON PARALLEL LOOP OUT OFF LOOP OUT OFF FUSSION 1800SA FUSE 16A / SB MIN. 8 FUSE CONCEIVED, DESIGNED, AND MANUFACTURED BY MACKIE DESIGNS INC, WOODINVILLE, WA, USA AND MACKIE EUROPE · MANUFACTURED IN ITALY · COPYRIGHT ©1998 · THE FOLLOWING ARE TRADEMARKS OR REGISTERED TRADEMARKS OF MACKIE DESIGNS INC. : "MACKIE", AND THE "RUNNING MAN" FIGURE · PATENT PENDING FS FUSE CONCEIVED, DESIGNED, AND MANUFACTURED BY MACKIE DESIGNS INC, WOODINVILLE, WA, USA AND MACKIE EUROPE · MANUFACTURED IN ITALY · COPYRIGHT ©1998 · THE FOLLOWING ARE TRADEMARKS OR REGISTERED TRADEMARKS OF MACKIE DESIGNS INC. : "MACKIE", AND THE "RUNNING MAN" FIGURE · PATENT PENDING FS TM FUSSION 1800S FUSSION 1800S MIXER 6 PLACEMENT The FUSSION 1800SA and 1800S subwoofers are designed to sit on the floor or sturdy stands. If you do, place the FUSSION 1800SA and 1800S on the bottom of the stack, side by side, and place the full-range active Fussion Series cabinets on top. If you stack two full-range cabinets, turn the upper cabinet upside down so the high-frequency driver is closest to the high-frequency driver in the lower cabinet. If you are setting them up outdoors, make sure they are under cover if you expect rain. · Position the loudspeakers so the highfrequency drivers are 2 to 4 feet above ear level for the audience (make allowances for a standing/dancing in the aisles audience). [. . . ] · Whenever possible, plug all the audio equipment's linecords into outlets which share a common ground. The distance between the outlets and the common ground should be as short as possible. 9 REPAIR Service for the FUSSION 1800SA and 1800S is available only from one of our authorized domestic service stations or at the factory service center, located in Whitinsville, Massachusetts. Service outside the United States can be obtained through local dealers or distributors. If your FUSSION 1800SA or 1800S needs service, please follow these instructions: 1. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE MACKIE FUSSION1800




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual MACKIE FUSSION1800 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.