Detailed instructions for use are in the User's Guide.
[. . . ] ®, KDFX®, Pitcher®, and LaserVerb®, KSP8 TM, K2600TM, K2500TM, and K2000TM are trademarks of Young Chang Co. , Ltd. All other products and brand names are trademarks or registered trademarks of their respective companies. Product features and specifications are subject to change without notice.
Part Number: 910382 Rev. A
CAUTION
RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE THE COVER NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL
The lightning flash with the arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of uninsulated "dangerous voltage" within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the product.
IMPORTANT SAFETY & INSTALLATION INSTRUCTIONS
INSTRUCTIONS PERTAINING TO THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS
WARNING - When using electric products, basic precautions should always be followed, including the following: 1) 2) 3) 4) 5) 6) 7) 8) 9) Read these instructions. [. . . ] You can get an external MIDI clock to pass through the Rumour or Mangler by changing the switch on the back panel from MIDI "OUT" to MIDI "THRU. " If you do this, however, MIDI events generated by your Rumour or Mangler will not be sent out the MIDI OUT/THRU port.
3-6
Using Your Rumour or Mangler Master Button
Tap Tempo LED
Tap|Tempo|LED: Blink|Tempo, |Don't|blink
Selects whether or not the Tap Tempo LED blinks in time with the system tempo.
Change Effect
Change|Effect: Load|automatically, |Cue|next|effect
Change Effect lets you "cue" effects, which means that you can select the next effect to load before you actually change to that effect. This offers a smooth way to move between effects without scrolling through the list of effects. The default is "Load automatically" (i. e. , cuing is off), which means that when you turn the BANK and PRESET knobs the current effect will change as you turn the knobs. The name of the newly-chosen effect will be displayed on the screen, just as you would expect. If you're in "Load automatically" mode, pressing the LOAD button resets the current preset to its unedited settings. When cuing is on ("Cue next effect"), you use the BANK and PRESET knobs to select an effect to cue. The unit will briefly display the name of the cued effect, then will resume displaying the name of the current effect. Press the LOAD button (which blinks when an effect is cued) to engage the selected effect. Program Change commands received through MIDI are ignored when Change Effect is set to "Cue next effect. "
Bypass Mode
Bypass|Mode: Effect|&|EQ, |Effect|only
Selects whether or not the EQ is bypassed along with the effect when the BYPASS button is pressed. The default is "Effect & EQ, " which means that the EQ is bypassed with the effect. "Effect only" means that the EQ remains active and only the effect is bypassed. You can still bypass the EQ when Bypass Mode is set to "Effect only", however, by using the EQ In/Out parameter (see page 3-12).
Show FX Parameters
Show|FX|Parameters: Basic, |Extended
Controls the number of effect parameters that you can edit. In "Extended" mode, all the algorithm parameters for the selected preset, up to 44 of them, are shown.
3-7
Using Your Rumour or Mangler Master Button
SysEx ID
SysEx|ID: 0, 1, 2. . .
Sets the SysEx ID of the unit. When you dump objects, the SysEx ID is sent as part of the dump message. The exception is ID 127, which will "broadcast" to all units.
SysEx Object Dump?
SysEx|Object|Dump?User1-4|||Load=Dump
This offers a way to back up your presets, by dumping them via SysEx to an external MIDI sequencer. Select this master parameter, then use the VALUE knob to select between the following options to specify what is to be dumped:
· · · · ·
User14 User1 User2 User3 User4
When you press the LOAD button the unit will dump the presets, displaying a screen like this for a few seconds:
Bank(s)|User1-4 have|been|dumped
See page 3-19 for more information about backing up and restoring your presets.
3-8
Using Your Rumour or Mangler Master Button
Erase User Banks?
Erase|User|Banks?User1-4||Load=Erase
Use this option to delete the contents of the user banks. You can erase all four banks in one fell swoop, or you can choose to erase individual banks. You cannot, however, delete a single preset (although you can overwrite it with a new one). The VALUE knob lets you select between the following options to specify what is to be erased:
· · · · ·
User14 User1 User2 User3 User4
Press the LOAD button to bring up the confirm dialog:
Erase|User1-4!||OK?Tap=OK||||Store=No
At this point, press TAP to erase the selected bank(s). [. . . ] MIDI generated by Rumour or Mangler will only be sent out the MIDI port if the switch is set to OUT. Software installation fails (e. g. , OS upgrade) Make sure no other MIDI events are being sent to unit while you are installing the new software. Wet/Dry level reverts to 100% Check setting of Wet/Dry Mode parameter. Effects don't change automatically Check setting of Change Effect parameter. [. . . ]