Manual abstract: user guide KINGSTON SH103S3
Detailed instructions for use are in the User's Guide.
[. . . ] Each module kit has been tested to run at DDR3-2000MHz at a low latency timing of 9-11-9 at 1. 65V. [. . . ] The JEDEC standard electrical and mechanical specifications are as follows: This special kit part number includes Kingston's HyperX high-performance cooling fan assembly (KHX-FAN).
FEATURES:
JEDEC standard 1. 5V ± 0. 075V Power Supply VDDQ = 1. 5V ± 0. 075V 667MHz fCK for 1333Mb/sec/pin d ye Ke 8 independent internal bank d ye Ke d Programmable CAS Latency: 5, 6, 7, 8, 9, 10 ye Ke Posted CAS Programmable Additive Latency: 0, CL - 2, or CL - 1 clock Programmable CAS Write Latency(CWL) = 7(DDR3-1333) 8-bit pre-fetch Burst Length: 8 (Interleave without any limit, sequential with starting address "000" only), 4 with tCCD = 4 which does not allow seamless read or write [either on the fly using A12 or MRS] Bi-directional Differential Data Strobe Internal(self) calibration : Internal self calibration through ZQ pin (RZQ : 240 ohm ± 1%) On Die Termination using ODT pin Average Refresh Period 7. 8us at lower then TCASE 85°C, 3. 9us at 85°C < TCASE . 95°C Asynchronous Reset PCB : Height 2. 401" (61. 00mm) w/ heatsink, double sided component
PERFORMANCE:
CL(IDD) Row Cycle Time (tRCmin) Refresh to Active/Refresh Command Time (tRFCmin) Row Active Time (tRASmin) Power UL Rating Operating Temperature Storage Temperature 9 cycles 49. 5ns (min. ) 110ns 36ns (min. ) 1. 800 W (operating per module) 94 V - 0 0o C to 85o C -55o C to +100o C
Document No. 4805507-001. A00
03/04/10
Page 1
Kingston
MODULE DIMENSIONS:
TECHNOLOGY
30. 00
Units: millimeters
133. 35
18. 80 15. 80 11. 00 8. 00 0. 00
0. 00
w/ heatsink assembly
mm 61 01 2. 4
Document No. Air Pressure At Zero Flow Accoustical Noise 12 VDC 8 - 13. 5 VDC 0. 09 amp 1. 08 watt 3000 ± 10% Frequency Generator (FG) 0. 43 m3/min 15. 02 CFM 2. 31 mm-H2O 0. 09 inch-H2O 25 (28 max. ) dB-A
HyperX Cooling Fan Assembly
Document No. 4805507-001. A00
Page 3
Kingston
ASSEMBLY:
Part Number: KHX-FAN
Document No. 4805507-001. A00
TECHNOLOGY
Page 4
Kingston
DIMENSIONS:
(Unit: Inches)
Document No. [. . . ] 4805507-001. A00