User manual DAXTEN VOYAGER UTP EXTENDER BROCHURE

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual DAXTEN VOYAGER UTP EXTENDER. We hope that this DAXTEN VOYAGER UTP EXTENDER user guide will be useful to you.


DAXTEN VOYAGER UTP EXTENDER BROCHURE: Download the complete user guide (89 Ko)

Manual abstract: user guide DAXTEN VOYAGER UTP EXTENDERBROCHURE

Detailed instructions for use are in the User's Guide.

[. . . ] Voyager UTP Extender Serial Addendum Voyager UTP Extender Serial Addendum The default settings for serial extension (9600bps, 8 data bits, no parity, 1 stop bit, RTS/CTS and DTR/DSR loopback) should be suitable for the majority of applications. [. . . ] 9600 19200 Figure 2 Remote Unit Baud Rate. Ensure that the jumpers are set correctly on both the Voyager UTP Local & Remote units Changing the Baud Rate on the Voyager UTP Local Unit All Local units are supplied with the baud rate preset at 9600/19200. Place the jumper over the posts as shown in Figure 3. 9600 / 19200 1200 Figure 3 Local Unit Baud Rate. 3. Set the hardware flow control jumpers in both Local and Remote Units to RTS/CTS Flow Control across CAT5 Link as described below. Ensure that the jumpers are set correctly on both the Voyager UTP Local & Remote units This mode will support most, but not all, serial mice and trackball devices. In most cases, we recommend that you use PS/2 mouse devices with the Voyager UTP extender. If your have a PC that does not have a PS/2 mouse port, then use a PS/2 Mouse on the remote unit and use a PS/2 to Serial mouse converter (2146-00C) on the Voyager Local Unit to connect to the PC Note: The drivers supplied with certain Wacom Graphics Tablets dynamically alter the baud rate and cannot be used with a Voyager UTP Extender system. Please contact Technical Support for more information. Hardware Flow Control The daughterboard's in both Local and Remote units have a series of jumpers which allow the selection of alternative hardware flow control schemes across the CAT5 link. Most applications will not require hardware flow control across the link, and therefore the flow control jumpers are set to loopback by default and should not need adjustment. [. . . ] 231 8004 Zürich info. ch@daxten. com www. daxten. ch Tel: +41 (0) 43 243 32 11 Fax: +41 (0) 43 243 32 16 · España C/Florian Rey, 8 50002 Zaragoza info. es@daxten. com www. daxten. com. es Tel: +34 902 197 662 Fax: +34 976 201 633 · Sweden info. se@daxten. com www. daxten. se · France B. P 04 - 77 Route de Cheptainville 91630 Marolles-en-Hurepoix info. fr@daxten. com www. daxten. fr Tel: +33 (0)1 64 56 09 33 Fax: +33 (0)1 69 14 88 34 · Denmark info. dk@daxten. com www. daxten. dk · · · [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DAXTEN VOYAGER UTP EXTENDER




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual DAXTEN VOYAGER UTP EXTENDER will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.