User manual DAXTEN THERMAL OPTIMISATION BROCHURE

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual DAXTEN THERMAL OPTIMISATION. We hope that this DAXTEN THERMAL OPTIMISATION user guide will be useful to you.


DAXTEN THERMAL OPTIMISATION BROCHURE: Download the complete user guide (1387 Ko)

Manual abstract: user guide DAXTEN THERMAL OPTIMISATIONBROCHURE

Detailed instructions for use are in the User's Guide.

[. . . ] Our certified specialists will carefully explore your IT environment, examining the airflow both within the floor plenum and above the raised floor to identify bypass airflow, loss of cooled air and hot spots. Measurements are taken at various locations such as 19" racks and CRAC units throughout your datacentre. Based on the findings, our specialists will work with you to compile a catalogue of techniques and products that allow you to reduce a large portion of your energy costs and to increase the efficiency factor of your cooling systems. 2 5 Daxten | Thermal Optimisation Best Practices 2. [. . . ] Depending on the size and environmental specifics of individual data centres, the cooling requirements and energy costs could be decreased by as much as 30%. A separation of the hot from the cold aisle is a standard in modern datacentres. Hot air recirculates into the cold aisle. 3 5 Daxten | Thermal Optimisation Best Practices Play it safe: Test before installing a complete cold aisle containment solution For companies who want to first test the efficiency of cold aisle containment the CoolControl Curtain is ideal. With the curtain, facility managers and IT managers can measure the actual savings and efficiency factors without placing strain on their budgets. Highlights · Cost-saving separation of the hot and the cold aisle (H/CAC) · Prevents recirculation of hot air in the cold aisle · Temperature difference between hot and cold aisle: more than 10° and 15°C · Up to 30% energy savings · Significant increase in cooling system efficiency · Easily installed: in hours not in weeks · No downtime required for installation · Ideal as test installation to measure cold aisle containment results · Compatible with all rack dimensions and vendors 3. Best Practice: Seal openings in the front of 19" cabinets PlenaFill blanking panels and PlenaForm air baffles are indispensable tools that increase the efficiency of hot aisle / cold aisle containment (H/CAC) and for general optimisation of data centre airflow. PlenaFill® blanking panel PlenaFill is an inexpensive solution for sealing the openings between servers preventing recirculation of hot air through the cabinet. The physical barrier keeps cold air at the front of the cabinet separated from the hot air at the back. This prevents hot spots and helps prevent hardware failures or downtime caused by overheating. PlenaFill is critical in separating hot and cold air areas in the server racks, which leads to an optimal cooling efficiencies. When PlenaFill blanking panels are deployed throughout the data centre, cooling units can operate more efficiently resulting in energy savings. PlenaFill blanking panels are made from lightweight non-flammable (fire rated to UL94-V0) material and can be installed into any 19" rack without tools. Each blanking panel is 27U with air tight perforations every 1U which can be torn to create smaller panels from 1U upwards. This patent protected and flexible design along with tool-free rivets makes for quick and easy installation. PlenaFill panels prevent the recirculation of hot air into the cold aisle. 4 Daxten | Thermal Optimisation Best Practices PlenaFill Highlights · Prevents hot and cold air mixing caused by bypass airflow · Fire rated to UL94-V0 · Tool free installation · Each panel covers 27U - separable in 1U sections · Easy to install in all 19" EIA racks · Extremely inexpensive, with high efficiency factor and quick ROI · Cost effective compared to metal or plastic blanking panels. PlenaForm® - Airflow Diffuser and Raised Floor Baffle PlenaForm is an airflow baffle that helps to guide airflow under the raised floor to the server racks. By directing the airflow, cooled air will not escape into unused areas in the raised floor increasing air pressure. Cooled air is directed effectively and efficiently to the openings in the raised floor where it is needed most. PlenaForm is a flexible airflow baffle system which helps to solve dynamic thermal imbalances in data centres. The baffles are die cut both vertically and horizontally in sections that can be removed to correct sizes for installation under the plenum. These individual sheets can be joined together creating impenetrable air barriers. PlenaForm baffles are constructed of a flame retardant polypropylene compound that is inert, non-conductive, and non-hygroscopic with a UL94-V0 rating. A server cabinet sealed with PlenaFill. PlenaForm Highlights · Control and balance data centre airflow · Separate hot aisles from cold aisles · No installation tools required · On-site configurable (width and height) · Fits any raised floor pedestal · Reduces energy consumption and operating costs · An inert, non-conductive and non-hygroscopic material · Flammability rating of UL94-V0 · RoHS and WEEE compliant · An energy saving and thermal tuning tool PlenaForm fits any raised floor pedestal. PlenaForm controls and balances airflow in the raised floor. 5 5 Daxten | Thermal Optimisation Best Practices 4. Best Practice: Optimise airflow through perforated floor tiles To ensure cooled air makes its way through the front of the cabinets and servers with ample pressure, it is necessary to have high density perforated floor tiles. To create an optimal pathway, it is advised to use high density airflow vented floor tiles which allow highplume stratification. [. . . ] Best Practice: Sealing cable openings in the raised floor The majority of companies today are investing in expensive cooling technologies to ensure the active hardware in the racks can operate in a cool environment without failure. In spite of these expensive investments, companies suffer from overheating and system failure caused by hotspots in the data centre. The culprits are almost always unsealed or insufficiently-sealed cable openings in the raised floor. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DAXTEN THERMAL OPTIMISATION




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual DAXTEN THERMAL OPTIMISATION will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.