User manual ASCOM TACTICAL OPENACCESS NODE C PRODUCT SHEET

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ASCOM TACTICAL OPENACCESS NODE C. We hope that this ASCOM TACTICAL OPENACCESS NODE C user guide will be useful to you.


ASCOM TACTICAL OPENACCESS NODE C PRODUCT SHEET: Download the complete user guide (284 Ko)

Manual abstract: user guide ASCOM TACTICAL OPENACCESS NODE CPRODUCT SHEET

Detailed instructions for use are in the User's Guide.

[. . . ] Built on proven hardware and software technology, Ascom compact network nodes are compliant with global industry and governmental standards for vehicle and military grade electronics. In alignment with NAto tAcoMs post 2000 architecture, Ascom tactical openAccess Node c (tAN c) provides interoperable access functionality towards mobile headquarter communication infrastructures. It connects local area subsystems with headquarter offices and other detached control facilities by creating an extended single all-Ip network. this allows fixed line communication equipment and field radio devices to exchange information that enhance situational awareness. Ascom tactical openAccess Node c is a high-performance militarygrade communication network access node with integrated routing functionality. [. . . ] Heterogeneous Number translation (NT) applied on called and Networking calling numbers for incoming and outgoing calls. Number Translation PBX includes multiple NT hooks in call routing Mesh Topology path, as e. g. High-Performance IAX trunks allow to setup bandwidth optimized Ethernet Switching VoIP channel bundles between TAN T nodes. ISDN, Voice Trunking Eurocom, SIP, and H. 323 trunks are available for connecting TAN T to existing telephony Site-to-Site VPN infrastructure, including PSTN. Automatic Number Number flood searching allows for deploying flat Resolution dialplans. Multi-Protocol Voice Switch (PBX) Conferencing, hotline, MLPP (available July 2011) Voice Applications alternate routing (available July 2011). Fast The TAN T PBX can convert between all supported development of customer specific applications. VoIP Gateway voice technologies, allowing it to be used as VoIP FXS, FXO, ISDN (Euro-ISDN, QSIG), Eurocom gateway, e. g. Standards, Protocols, (a, b, c, STANAG), SIP, H. 323 (available March Codecs Multiple TAN T nodes can build a fully inter2011), IAX, G. 711, G. 723, GSM connected voice network. Flexible number Voice Trunking Security translation per voice trunk allows for integration into different numbering domains. Encrypted site-to-site IPSec VPNs supporting Routing algorithms optimized for low bandwidth, IPSec VPN multiple authentication methods. Available Integration of HF/ high latency radio networks are available and Q3/2011. VHF/LOS Radios allow to route traffic over wireless radio Firewall supporting filtering rules with access to networks. Stateless and stateful Firewall/NAT TAN T provides network services to locally filtering. Network address translation (NAT) for Network Services attached LANs, as DHCP, DNS, and NTP services. The built-in QoS engine allows for shaping traffic Import and management of PKI certificates and DiffServ Traffic Key Store with prioritization based on DiffServ or 802. 1D CRLs. All sensitive data in TAN T can be erased within few milliseconds by pressing emergency erase Data features Emergency Erase hardware or software key, also when node is TAN T provides non-blocking, line rate switching switched off. Switching / VLAN for all LAN Ethernet ports (copper and optical) System Management including support for 802. 1Q VLAN. TAN T routing engine supports static, OSPF, BGP, Web GUI for configuring and monitoring TAN T, PIM-SM, and IGMP routing protocols. Specialized remotely through IP network, or locally through routing algorithms are available for mesh laptop/PC connected to service Ethernet port. [. . . ] 802. 11 a/b/g Local/Remote Standard UDP based syslog for remote and local Logging logging of system events. product sheet: AscoM tActIcAL openAccess® Node c and Bps 2. 3 4 Technical Specification Environmental conditions Temperature Relative Humidity Power consumption 50W typical ET P104: 3. 1 W ECOM P104: 4, 5W DSL P104: 5. 6 W AtMUX: 25 W peak, 10 W typical 0. . . +50 °C operation (with internal heating), Main unit -25. . . +70 °C storage 5. . . 95% (non condensing) operation 0. . . 99% (non condensing) storage Expansion units EMC (industrial usage) Emissions Immunity Mechanical 19" housing with 19" mounting adapters Size (LxHxD)/mm Weight Available interfaces Main Unit Management Ethernet Switched Ethernet Optical Ethernet Relay in Relay out Serial port 1 x 100Base-TX 4 x 1000Base-T 2 x 1000Base-X, multi mode or single mode fiber modules for 0, 5-160 km 1x 1x 1 x RS-232 420x89x300 (2U) 7 kg EN 55022 Class B EN 61000-6-2 Standard configuration The standard configurations include following units and externally available interfaces: openAccess Node C112: 1 x Main unit with: 1 x 10/100Base-TX 4 x 10/100/1000Base-T 2 x 1000Base-X, single mode 1 x Relay in 1 x Relay out 1 x RS-232 1 x ET P104 with: 4 x E1 1 x DSL P104 with: 4 x SHDSL 1 x AtMUX with: 3 x FXS 1 x FXO openAccess Node C107: 1 x Main unit with: 1 x 10/100Base-TX 4 x 10/100/1000Base-T 2 x 1000Base-X, single mode 1 x Relay in 1 x Relay out 1 x RS-232 Internal expansion units ET P104 DSL P104 AtMUX ECOM P104 Power Input voltage 22-50 VDC or 230 VAC with external power supply 8 x E1 per unit 4 x G. SHDSL (2-wire) per unit 1 x ET P104 with: 30 x a/b FXS or FXO per unit; configurable in groups 8 x E1 of 4; reserves 1xE1 port 1 x DSL P104 with: EUROCOM EES / D/1: 2xA (10 pin) or 4xB or 4xC 8 x SHDSL Although the information in this publication is represented in good faith and believed to be correct, Ascom makes no representations or warranties as to the completeness or accuracy of the information. In no event will be Ascom responsible for damages of any nature whatsover resulting from the use of or reliance upon the information contained in this document. Ascom gives no warranty and makes no representation that any of its products contained in this document are designed for any particular use or purpose. the graphics and contents of this document are the copyrighted work of Ascom and contain proprietary trademarks and tradenames of Ascom. 01. 2011 Ascom (Switzerland) Ltd. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ASCOM TACTICAL OPENACCESS NODE C




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ASCOM TACTICAL OPENACCESS NODE C will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.